EMAIL THIS PAGE TO A FRIEND
03079 Sigma-Aldrich

Ethylbenzene

analytical standard

Synonym: NSC 406903, Phenylethane

  • CAS Number 100-41-4

  • Linear Formula C6H5C2H5

  • Molecular Weight 106.17

  •  Beilstein Registry Number 1901871

  •  EC Number 202-849-4

  •  MDL number MFCD00011647

  •  PubChem Substance ID 329747548

  •  eCl@ss 39011201

Purchase

Properties

Related Categories A-F, A-L, Additional Standards, All Alphabetically Sorted, Alpha Sort,
grade   analytical standard
vapor density   3.7 (vs air)
vapor pressure   10 mmHg ( 20 °C)
  19 mmHg ( 37.7 °C)
InChI Key   YNQLUTRBYVCPMQ-UHFFFAOYSA-N
assay   ≥99.5% (GC)
autoignition temp.   810 °F
shelf life   limited shelf life, expiry date on the label
expl. lim.   6.7 %
refractive index   n20/D 1.495(lit.)
  n20/D 1.495
bp   136 °C(lit.)
mp   −95 °C(lit.)
density   0.867 g/mL at 25 °C(lit.)

Price and Availability

Safety & Documentation

Safety Information

Symbol 
Signal word 
Danger
Hazard statements 
Target organs 
Missing Phrase - TD-124117
RIDADR 
UN1175 - class 3 - PG 2 - Ethylbenzene
WGK Germany 
1
RTECS 
DA0700000
Flash Point(F) 
59 °F
Flash Point(C) 
15 °C
Protocols & Articles

Articles

ASTM D5134: GC Analysis of Hydrocarbons on Petrocol® DH 50.2

From our library of Articles, Sigma-Aldrich presents ASTM D5134: GC Analysis of Hydrocarbons on Petrocol® DH 50.2
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography

ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 30 m Column

From our library of Articles, Sigma-Aldrich presents ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 30 m Column
Keywords: Chromatography, Flame ionization detector, Gas chromatography

ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 60 m Column

From our library of Articles, Sigma-Aldrich presents ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 60 m Column
Keywords: Chromatography, Gas chromatography

GC Analysis of Aromatics in Reforµlated Gasoline on Equity®-1

From our library of Articles, Sigma-Aldrich presents GC Analysis of Aromatics in Reforµlated Gasoline on Equity®-1
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Aromatics in Reforµlated Gasoline on SLB®-IL111

From our library of Articles, Sigma-Aldrich presents GC Analysis of Aromatics in Reforµlated Gasoline on SLB®-IL111
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Separation

GC Analysis of Aromatics in Reforµlated Gasoline on SUPELCOWAX® 10

From our library of Articles, Sigma-Aldrich presents GC Analysis of Aromatics in Reforµlated Gasoline on SUPELCOWAX® 10
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of BTEX, Undecane, and Tridecane on SLB®-IL100

From our library of Articles, Sigma-Aldrich presents GC Analysis of BTEX, Undecane, and Tridecane on SLB®-IL100
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Gasoline Residue in Arson Samples on a 100% Methyl Column after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Gasoline Residue in Arson Samples on a 100% Methyl Column after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Sample preparations, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Hydrocarbons in Gasoline on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents GC Analysis of Hydrocarbons in Gasoline on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Size-exclusion chromatography

GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH, Isothermal

From our library of Articles, Sigma-Aldrich presents GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH, Isothermal
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Separation

GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH

From our library of Articles, Sigma-Aldrich presents GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography

GC Analysis of Industrial Solvents on Equity®-1701

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on Equity®-1701
Keywords: Chromatography, Flame ionization detector, Gas chromatography

GC Analysis of Industrial Solvents on Equity®-1

From our library of Articles, Sigma-Aldrich presents GC Analysis of Industrial Solvents on Equity®-1
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography

GC Analysis of Ionic Liquid Test Mix on SLB®-IL100 (15 m x 0.10 mm I.D., 0.08 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL100 (15 m x 0.10 mm I.D., 0.08 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Ionic Liquid Test Mix on SLB®-IL100 (30 m x 0.25 mm I.D., 0.20 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL100 (30 m x 0.25 mm I.D., 0.20 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Ionic Liquid Test Mix on SLB®-IL59 (15 m x 0.10 mm I.D., 0.08 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL59 (15 m x 0.10 mm I.D., 0.08 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Ionic Liquid Test Mix on SLB®-IL59 (30 m x 0.25 mm I.D., 0.20 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL59 (30 m x 0.25 mm I.D., 0.20 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Ionic Liquid Test Mix on SLB®-IL76 (15 m x 0.10 mm I.D., 0.08 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL76 (15 m x 0.10 mm I.D., 0.08 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Ionic Liquid Test Mix on SLB®-IL76 (30 m x 0.25 mm I.D., 0.20 μm)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Ionic Liquid Test Mix on SLB®-IL76 (30 m x 0.25 mm I.D., 0.20 μm)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Refinery Grade Unleaded Gasoline on TCEP (15 m x 0.10 mm I.D., 0.18 μm), Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents GC Analysis of Refinery Grade Unleaded Gasoline on TCEP (15 m x 0.10 mm I.D., 0.18 μm), Fast GC Analysis
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Solvents on a Packed Column (3% SP-1500 on Carbopack™ B)

From our library of Articles, Sigma-Aldrich presents GC Analysis of Solvents on a Packed Column (3% SP-1500 on Carbopack™ B)
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of TCEP Test Mix on SLB®-IL100, 100 °C Oven Temp.

From our library of Articles, Sigma-Aldrich presents GC Analysis of TCEP Test Mix on SLB®-IL100, 100 °C Oven Temp.
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of TCEP Test Mix on SLB®-IL100, 110 °C Oven Temp.

From our library of Articles, Sigma-Aldrich presents GC Analysis of TCEP Test Mix on SLB®-IL100, 110 °C Oven Temp.
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of TCEP Test Mix on SLB®-IL100, 80 °C Oven Temp.

From our library of Articles, Sigma-Aldrich presents GC Analysis of TCEP Test Mix on SLB®-IL100, 80 °C Oven Temp.
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification

GC Analysis of Volatiles in Water on Equity®-1 after SPME using 30 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Water on Equity®-1 after SPME using 30 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography, Solid phase microextractions

GC Analysis of Volatiles in Water on SPB®-1 after SPME using 100 μm PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles in Water on SPB®-1 after SPME using 100 μm PDMS Fiber
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Solid phase microextractions

GC Analysis of Volatiles on SPB®-624, Direct Injection

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles on SPB®-624, Direct Injection
Keywords: Chromatography, Gas chromatography, Purification, Size-exclusion chromatography

GC Analysis of Volatiles on VOCOL® after SPME using 75 μm Carboxen/PDMS Fiber

From our library of Articles, Sigma-Aldrich presents GC Analysis of Volatiles on VOCOL® after SPME using 75 μm Carboxen/PDMS Fiber
Keywords: Chromatography, Gas chromatography, Mass spectrometry, Purification, Solid phase microextractions

GC Analysis of Xylene Isomers on SLB®-IL60

From our library of Articles, Sigma-Aldrich presents GC Analysis of Xylene Isomers on SLB®-IL60
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Separation, Size-exclusion chromatography

GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column

From our library of Articles, Sigma-Aldrich presents GC Analysis of a 56-Component Industrial Solvents Mix on SLB®-IL60, Comparison to a Polyethylene Glycol (PEG) Column
Keywords: Chromatography, Flame ionization detector, Gas chromatography

HPLC Analysis of Structural Isomers on Discovery® Zr-Carbon

From our library of Articles, Sigma-Aldrich presents HPLC Analysis of Structural Isomers on Discovery® Zr-Carbon
Keywords: Chromatography, High performance liquid chromatography

US EPA Method 502.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap, ELCD Signal

From our library of Articles, Sigma-Aldrich presents US EPA Method 502.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap, ELCD Signal
Keywords: Chromatography, Gas chromatography, Hall electrolytic conductivity detector, Photo-ionization detector, Purge and trap, Sample preparations

US EPA Method 502.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap, PID Signal

From our library of Articles, Sigma-Aldrich presents US EPA Method 502.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap, PID Signal
Keywords: Chromatography, Gas chromatography, Hall electrolytic conductivity detector, Photo-ionization detector, Purification

US EPA Method 524.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 524.2: GC Analysis of Volatiles on VOCOL® (105 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Size-exclusion chromatography

US EPA Method 624: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 624: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 624: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 624: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 624: GC Analysis of Volatiles on VOCOL® (30 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 624: GC Analysis of Volatiles on VOCOL® (30 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Size-exclusion chromatography

US EPA Method 624: GC Analysis of Volatiles on VOCOL® (60 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 624: GC Analysis of Volatiles on VOCOL® (60 m x 0.53 mm I.D.) after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Size-exclusion chromatography

US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Direct Injection, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Direct Injection, Fast GC Analysis
Keywords: Chromatography, Flame ionization detector, Gas chromatography, Purification, Size-exclusion chromatography

US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 after Purge & Trap using "M" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on Equity®-1 after Purge & Trap using "M" Trap
Keywords: Chromatography, Environmental, Flame ionization detector, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on VOCOL® after Purge & Trap using "M" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8015 (modified): GC Analysis of Gasoline Range Organics (GRO) on VOCOL® after Purge & Trap using "M" Trap
Keywords: Chromatography, Environmental, Flame ionization detector, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Gas chromatography mass spectrometry, Mass spectrometry, Purge and trap, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap

From our library of Articles, Sigma-Aldrich presents US EPA Method 8260: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap
Keywords: Chromatography, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on SPB®-624 after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis

From our library of Articles, Sigma-Aldrich presents US EPA Method OLM04.2 VOA: GC Analysis of Volatiles on VOCOL® after Purge & Trap using "K" Trap, Fast GC Analysis
Keywords: Chromatography, Environmental, Gas chromatography, Purification, Solid phase microextractions

US EPA Method TO-17: GC Analysis of Volatiles on VOCOL® after Collection/Desorption using Air Toxics Tube

From our library of Articles, Sigma-Aldrich presents US EPA Method TO-17: GC Analysis of Volatiles on VOCOL® after Collection/Desorption using Air Toxics Tube
Keywords: Air Monitoring, Chromatography, Flame ionization detector, Gas chromatography, Purification

Related Content

Flavor and Fragrance Analysis

We offer quality product solutions in all three stages of analysis to help achieve fast, accurate results. Below, you can learn more about our workflow solutions for sample preparation, separation, d...
Keywords: Calorimetry, Environmental, Gas chromatography, Mass spectrometry, Pesticides, Sample preparations, Separation

Peer-Reviewed Papers
15

References

Related Products

Technical Service:

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Bulk Ordering & Pricing:

Need larger quantities for your development, manufacturing or research applications?