Z710474 Sigma

Hanna waterproof conductivity meter model HI 9033

limit 0-50 °C temperature (32-122 °F), size 196 mm × 80 mm × 60 mm

DOWNLOAD MSDS (PDF)

Properties

Related Categories Conductivity Meters, Hanna, Hanna Conductivity, Labware, Manufacturer Browser More...
measuring range   0-1999 μS/cm conductivity, accuracy: 1%, resolution: 1 mS/cm
  0.0-199.9 conductivity, accuracy: 1%, resolution: 0.1 mS/cm
  0.0-199.9 μS/cm conductivity, accuracy: 1%, resolution: 0.1 mS/cm
  0.00-19.99 conductivity, accuracy: 1%, resolution: 0.01 mS/cm
limit   0-50 °C temperature (32-122 °F)
size   196 mm × 80 mm × 60 mm
weight   1.4 kg

Description

General description

The increasing demand for instant results of on-field analysis, without waiting for lab tests, has produced a growing necessity across the globe. Adverse weather conditions associated with use in the field, can damage a meter, rapidly deteriorating its performance and life. Due to these demands, Hanna Instruments has developed the HI 9033 to satisfy all field application needs.

All conductivity readings, from deionized water to brine, are performed through the rugged 4-Ring potentiometric probe. This probe is so technologically advanced that it can measure any sample in any range of the meter without requiring re-calibration. BEPS (Battery Error Preventive System) will alert the user when low batteries could effect the readings. HI 9033 comes supplied complete with an HI 76302W conductivity probe, calibration screwdriver, 9V battery and instruction manual in a rugged carrying case.

• Water-Resistant Housing HI 9033 will resist the ingress of water and dust to protect its advanced electronic circuitry
• 4 Ranges of Measurements With just 1 probe, HI 76302W will measure samples from deionized water to brine, without requiring re-calibration. ATC is incorporated into the probe
• 4-Ring Potentiometric Method Excels The proven 4-Ring potentiometric method is so technologically advanced that it renders the 2-ring Amperometric method obsolete
• Battery Error Preventive System BEPS will never let you take erroneous readings caused by low batteries

Calibration: Manual
Temp. Compensation: Automatic
4-Ring Probe: HI 76302W

Price and Availability

Customers Also Viewed

Hanna conductivity/TDS meter model HI 9835

size 196 mm × 80 mm × 60 mm, weight 500 g