• USA Home
  • Search Results

  • essential oils

EMAIL THIS PAGE TO A FRIEND

view products:

Compare products:

Select the checkbox on up to 4 items, then click 'compare' for a detailed product comparison

*Please select more than one item to compare

    Search term:"essential oils"

    86 matches found for essential oils

    GC Analysis of Kennewick Peppermint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Kennewick Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250...

    GC Analysis of Native Spearmint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 °C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °...

    GC Analysis of Native Spearmint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C...

    GC Analysis of Willamette Peppermint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID,...

    GC Analysis of Distilled Lime Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 °C (4 min), then 4 °C/min to 200 °C (5 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Cat...

    GC Analysis of L-Carvone Enantiomer in Native Spearmint Essential Oil on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categories A...

    GC Analysis of Lavender Flower Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C, 3 °C/min to 280 °C (5 min) carrier gas helium, 30 cm/s sample Lavender flower essential oil injection 0.5 µL20:1 split inj. temp. 280 °C detector MSD Categories Analytical Chromatography, GC Applications, Essential Oils Featured ...

    GC Analysis of Native Spearmint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250...

    GC Analysis of Bitter Orange Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50-250C (10 min) at 3C/min carrier gas He at 99.5 kPa (30.0 cm/s) sample cold-pressed oils obtained from the peel of the fruits injection split; split ratio,1:100; injected volume, 1.0 µL of diluted oil detector FID, 280 °C Categories Analy...

    GC Analysis of Willamette Peppermint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 mm (29505-U) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 2...

    GC Analysis of Distilled Lime Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Cate...

    GC Analysis of Geranium Bourbon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 °C (2 min), 2 °C/min to 230 °C (1 min) carrier gas helium, 20 cm/sec @ 155 °C sample neat oil injection 0.2 µL, 100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors ...

    GC Analysis of L-Carvone Enantiomer in Scotch Spearmint Essential Oil on Astec® CHIRALDEX® G-TA

    column Astec CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), 2 °C/min to 170 °C (15 min) carrier gas helium, 25 cm/sec, set at 110 °C sample Scotch Spearmint Oil, neat injection 0.1 µL100:1 split liner 4 mm I.D., split type, cup design inj. temp. 250 °C detector FID, 250 ...

    GC Analysis of Cold Pressed Bergamot Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min to 250 °C (5 min) carrier gas helium, 30 cm/sec, constant sample cold pressed bergamot oil injection Wet needle, 100:1 split inj. temp. 250 °C detector FID, 300 °C Analysis Note Bergamot oil is used in cosmetic preparations ...

    GC Analysis of D & L-Carvone Enantiomers in Caraway Essential Oil (Spiked with L-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Dill Seed Oil + L- Carvone Spike, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of Lavender Flower Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.20 µm (29505-U) oven 50 °C, 3 °C/min to 270 °C (5 min) carrier gas helium, 30 cm/s sample Lavender flower essential oil injection 0.5 µL50:1 split inj. temp. 270 °C detector FID, 270 °C Categories Analytical Chromatography, GC Applications, Essential Oils Feat...

    GC Analysis of Sicilian Mandarin Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min. to 250 °C (10 min), 10 °C/min to 270 °C (3 min) carrier gas helium, 30 cm/sec, constant sample Sicilian mandarin essential oil diluted 1:10 in n-hexane injection 1 µL, 50:1 split inj. temp. 280 °C detector FID, 280 °C Analy...

    GC Analysis of Cold Pressed Lemon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 °C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Cold Pressed Lemon Oil, (Sigma), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categ...

    GC Analysis of Willamette Peppermint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, ...

    GC Analysis of Distilled Lime Essential Oil on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

    column Equity-1, 15 m x 0.10 mm I.D., 0.10 µm (28039-U) oven 75 °C (1 min), 35 °C/min to 200 °C (1 min) carrier gas helium, 45 cm/sec constant sample distilled lime oil, neat injection 0.10 µL, 300:1 split liner 2 mm I.D., straight inj. temp. 250 °C detector FID, 250 °C Categories Analytical Chromat...

    GC Analysis of D-Carvone Enantiomer in Dill Seed Essential Oil on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 °C (1 min), then 2 °C/min to 170 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Dill Seed Oil, neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categories Analytic...

    GC Analysis of Distilled Lime Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C C...

    GC Analysis of Cold Pressed Lemon Essential Oil on Equity®-1 and Equity®-5

    column Equity-5, 30 m x 0.25 mm I.D., 0.25 µm (28089-U) column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) column temp. 75 °C (8 min) to 200 °C @ 4 °C/min (10 min) flow rate helium, 30 cm/sec @ 110 °C sample cold pressed lemon oil injection wet needle, split 100:1 liner split, cup design inj. t...

    GC Analysis of Scotch Spearmint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 mm (28471-U) oven 75 C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C C...

    GC Analysis of Cold Pressed Lemon Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (4 min), then 4 °C/min to 200 °C (5 min) carrier gas helium, 25cm/ sec set at 110C sample Cold Pressed Lemon Oil, (Sigma), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C Categori...

    GC Analysis of Lavender Spike Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 °C, 3 °C/min to 280 °C (5 min) carrier gas helium, 30 cm/s sample Lavender spike essential oil injection 1 µL200:1 split inj. temp. 280 °C detector MSD Categories Analytical Chromatography, GC Applications, Essential Oils Featured Indust...

    GC Analysis of Scotch Spearmint Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 °C/min to 200 °C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 °C ...

    GC Analysis of Kennewick Peppermint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 °C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Kennewick Peppermint Oil, (A.M. Todd Sample), neat liner 4 mm I.D. cup injector inj. temp. 250 °C detector 0.1 µL, 100:1 split detector FID, 25...

    GC Analysis of Cold-Pressed Mandarin Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50C at 3C/min to 250C, held 10 min, at 10C/min to 270C, held 3 min carrier gas He at 30.1 cm/s and pressure of 99.8 kPa detector FID, 280 °C Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and...

    GC Analysis of Native Spearmint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 °C (8 min), then 4 °C/min to 200 °C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 °C detector FID, 250 ...