EMAIL THIS PAGE TO A FRIEND

Product Category
Materials Science(182)

view products:

Compare products:

Select the checkbox on up to 4 items, then click 'compare' for a detailed product comparison

*Please select more than one item to compare

    Search term:"fragrance"

    204 matches found for fragrance

    GC Analysis of Cold Pressed Lemon Essential Oil on Equity®-1 and Equity®-5

    column Equity-5, 30 m x 0.25 mm I.D., 0.25 µm (28089-U) column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) column temp. 75 C (8 min) to 200 C @ 4 C/min (10 min) flow rate helium, 30 cm/sec @ 110 C sample cold pressed lemon oil injection wet needle, split 100:1 liner split, cup design inj. temp....

    GC Analysis of Spearmint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), 4 C/min to 200 C (5 min) carrier gas helium, 25 cm/sec @ 155 C injection 0.2 µL, 100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and Fragrances Legal...

    GC Analysis of Italian Bergamot Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 C (2 min), 2 C/min to 230 C (1 min) carrier gas helium, 20 cm/sec @ 155 C injection 0.2 muL100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and Fragrances Legal ...

    GC Analysis of Volatiles in Water on VOCOL after SPME using 100 μm PDMS Fiber

    sample/matrix 50ppb each analyte in 1.8 mL saturated salt water desorption process 230 C, splitless (closed 3 min) extraction 5 min immersed in water with rapid stirring SPME fiber polydimethylsiloxane, 100 µm film (57300-U) column VOCOL, 10 m x 0.20 mm I.D., 1.2 µm (24129-U) oven 40 C (0.75 min), 2...

    GC Analysis of Bergamot Essential Oil on SLB-5ms (10 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

    column SLB-5ms, 10 m x 0.10 mm I.D., 0.10 µm (28465-U) oven 50 C, 14.0 C/min to 250 C carrier gas hydrogen, 57.0 cm/sec, 184.2 kPa sample bergamot oil, diluted 10:1 in hexane injection 0.4 µL, 600:1 split liner 0.75 mm ID inj. temp. 300 C detector FID, 300 C Categories Analytical Chromatography, GC ...

    GC Analysis of D-Carvone Enantiomer in Caraway Essential Oil on Astec® CHIRALDEX® G-TA

    column CHIRALDEX GTA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 C (1 min), then 2 C/min to 170 C (15 min) carrier gas helium, 25cm/ sec set at 110Chelium, 25cm/ sec set at 110 sample Caraway Oil, neat injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 ...

    GC Analysis of D & L-Carvone Enantiomers on Astec CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 C (1 min), then 2 C/min to 170 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample D & L- Carvone Mix, neat, (L in excess) injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Cat...

    GC Analysis of Peppermint Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 60 m x 0.25 mm I.D., 0.25 µm (24081) oven 75 C (4 min.), 4 C/min. to 200 C (5 min.) carrier gas helium, 25 cm/sec @ 155 C injection 0.2 µL, 100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and Fragrances Le...

    GC Analysis of Cold Pressed Lemon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 75 C (4 min), then 4 C/min to 200 C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Cold Pressed Lemon Oil, (Sigma), neat injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categorie...

    HPLC Analysis of 2-Phenylpropionic Acid Enantiomers on Astec® CYCLOBOND® I 2000 HP-RSP

    column CYCLOBOND I 2000 HP-RSP, 25 cm x 4.6 mm I.D., 5 µm particles (24024AST) column temp. 25 C mobile phase [A] 10 mM ammonium acetate, pH 4.0; [B] acetonitrile; (75:25, A:B) flow rate 1 ml/min sample 1 mg/mL in methanol injection 1 µl detector UV, 235 nm Categories Analytical Chromatography, Chir...

    GC Analysis of Geranium Bourbon Essential Oil on SUPELCOWAX® 10

    column SUPELCOWAX 10, 30 m x 0.25 mm I.D., 0.25 µm (24079) oven 50 C (2 min), 2 C/min to 230 C (1 min) carrier gas helium, 20 cm/sec @ 155 C sample neat oil injection 0.2 µL, 100:1 split detector FID Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry Flavors and ...

    HPLC Analysis of an Energy Drink on Ascentis® Express HILIC (ELSD Detection)

    column Ascentis Express HILIC, 5 cm x 3 mm I.D., 2.7 µm particles (53967-U) column temp. 35 C mobile phase [A] 100 mM ammonium acetate, pH 5 (titrated with acetic acid) [B] water [C] acetonitrile; (9:1:90, A:B:C:) flow rate 0.6 ml/min sample Energy Drink Diluted 1:9 in acetonitrile injection 2 µl de...

    HPLC Analysis of Isoflavones on Ascentis® Phenyl

    column Ascentis Phenyl, 15 cm x 4.6 mm I.D., 5 µm particles (581616-U) column temp. 35 C mobile phase [A] 10 mM ammonium formate (pH 3.0 with concentrated formic acid), [B] methanol flow rate 1 mL/minsplit to the MS sample glycitein, genistein at 1 µg/mL, equol at 50 µg/mL and daidzin, glycitin, gen...

    GC Analysis of Petitgrain Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 C/min to 200 C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Petitgrain Oil, Paraguay, neat (W523607) injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categorie...

    GC Analysis of Lavender Spike Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 50 C, 3 C/min to 280 C (5 min) carrier gas helium, 30 cm/s sample Lavender spike essential oil injection 1 muL200:1 split inj. temp. 280 C detector MSD Categories Analytical Chromatography, GC Applications, Essential Oils Featured Industry ...

    GC Analysis of Native Spearmint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (8 min), then 4 C/min to 200 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Native Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Ca...

    HPLC Analysis of Cosmetic Preservatives on Ascentis® Express C18 (0.6 ml/min)

    column Ascentis Express C18, 7.5 cm x 3 mm I.D., 2.7 µm particles (53812-U) column temp. 35 C mobile phase [A] water; [B] methanol; (55:45, A:B) flow rate 0.6 ml/min sample methyl-, benzylparaben, 50 mg/L; ethylparaben, 30 mg/L; propyl-, butylparaben, 100 mg/L; 2-phenoxyethanol, 1.5 g/L; 1-phenoxy-2...

    GC Analysis of Distilled Lime Essential Oil on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

    column Equity-1, 15 m x 0.10 mm I.D., 0.10 µm (28039-U) oven 75 C (1 min), 35 C/min to 200 C (1 min) carrier gas helium, 45 cm/sec constant sample distilled lime oil, neat injection 0.10 µL, 300:1 split liner 2 mm I.D., straight inj. temp. 250 C detector FID, 250 C Categories Analytical Chromatograp...

    GC Analysis of Lemon Essential Oil on SLB®-5ms (10 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

    column SLB-5ms, 10 m x 0.10 mm I.D., 0.10 µm (28465-U) oven 40 C, 50 C/min to 320 C carrier gas hydrogen, 81.5 cm/sec constant sample lemon essential oil in hexane injection 0.4 µl in the split mode (300:1) inj. temp. 320 C detector FID, 320 C Categories Analytical Chromatography, GC Applications, E...

    GC Analysis of Lactone Enantiomers on β-DEX™ 110

    column beta-DEX 110, 30 m x 0.25 mm I.D., 0.25 µm (24301) oven 90 C, 1 C/min to 200 C carrier gas helium, 20 cm/sec @ 90 C sample 0.5 mg/mL in methylene chloride injection 1 µL, 100:1 split inj. temp. 300 C detector FID, 300 C Categories Analytical Chromatography, GC Applications, Esters, Enantiomer...

    GC Analysis of Scotch Spearmint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 mm (28471-U) oven 75 C (8 min), then 4 C/min to 200 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil, (A.M. Todd Sample), neat injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Cate...

    GC Analysis of β-Pinene Enantiomers on Astec® CHIRALDEX® B-PM

    column Astec CHIRALDEX B-PM, 30 m x 0.25 mm I.D., 0.12 µm (76023AST) oven 50 C carrier gas helium, 30 psi sample 5 mg/mL in ethanolpeak 1: d-beta-pinenepeak 2: l-beta-pinene injection 0.2 µL, 80:1 split inj. temp. 250 C detector FID, 250 C Categories Analytical Chromatography, GC Applications, Enant...

    HPLC Analysis of Procyanidins on Ascentis® Phenyl

    column Ascentis Phenyl, 15 cm x 4.6 mm I.D., 5 µm particles (581616-U) column temp. 35 C mobile phase [A] 10 mM ammonium formate, (pH 3.0 with concentrated formic acid): [B] acetonitrile; (85:15, A:B) flow rate 1.0 ml/min split to the MS sample 10 mg/mL in 85:15, 10 mM ammonium formate, (pH 3.0 with...

    GC Analysis of Willamette Peppermint Essential Oil on Equity®-1

    column Equity-1, 30 m x 0.25 mm I.D., 0.25 µm (28046-U) oven 75 C (8 min), then 4 C/min to 200 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Willamette Peppermint Oil, (A.M. Todd Sample), neat injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250...

    GC Analysis of Cold Pressed Lemon Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 C (4 min), then 4 C/min to 200 C (5 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 µL, 100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categori...

    GC Analysis of Petitgrain Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 C (8 min), then 4 C/min to 200 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Petitgrain Oil, Paraguay, neat (W523607) injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categories...

    GC Analysis of Patchouli Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 50 C (0 min), then 5 C/min to 250 C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Patchouli Oil, neat (W283800) injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categories Analytica...

    GC Analysis of Kennewick Peppermint Essential Oil on SLB®-5ms

    column SLB-5ms, 30 m x 0.25 mm I.D., 0.25 µm (28471-U) oven 75 C (8 min), then 4 C/min to 200 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Kennewick Peppermint Oil, (A.M. Todd Sample), neat liner 4 mm I.D. cup injector inj. temp. 250 C detector 0.1 µL, 100:1 split detector FID, 250 C ...

    GC Analysis of Distilled Lime Essential Oil on SLB®-IL60

    column SLB-IL60, 30 m x 0.25 mm I.D., 0.25 µm (29505-U) oven 75 C (4 min), then 4 C/min to 200 C (10 min) carrier gas helium, 25cm/ sec set at 110C sample Distilled Lime Oil, Mexico, neat (W263109) injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250 C Categor...

    GC Analysis of D & L-Carvone Enantiomers in Scotch Spearmint Essential Oil (Spiked with D-Carvone Enantiomer) on Astec® CHIRALDEX® G-TA

    column CHIRALDEX G-TA, 30 m x 0.25 mm I.D., 0.12 µm (73033AST) oven 40 C (1 min), then 2 C/min to 170 C (15 min) carrier gas helium, 25cm/ sec set at 110C sample Scotch Spearmint Oil + D- Carvone Spike, neat injection 0.1 muL100:1 split liner 4 mm I.D. cup injector inj. temp. 250 C detector FID, 250...