Skip to Content
Merck
All Photos(1)

Documents

SLGPB5010

Millipore

Millex® polyethersulfone inline filter

pore size 0.22 μm, diam. 50 mm, sterile, hydrophilic, 1/4-1/2 in. hose barb with outlet bell

Sign Into View Organizational & Contract Pricing

Synonym(s):
0.22 μm PES syringe filter, Express PLUS PES in-line filter, Millex-GP in-line filter with filling bell, Millex® 50 mm Filter Unit, Millex® GP50, disposable syringe filter, polyethersulfone syringe filter, sterile pressure filter unit
UNSPSC Code:
41104922
eCl@ss:
32031690
NACRES:
NB.22

material

methacrylate-butadiene-styrene (MBS) housing
polyethersulfone membrane

Quality Level

sterility

γ-irradiated
sterile

product line

Millex®

feature

holdup volume< 1 mL
hydrophilic
Research Use Only (RUO)

manufacturer/tradename

Millex®

parameter

3.3 bar max. inlet pressure (50 psi)
45 °C max. temp.
~390 mL/min water flow rate at 15 psig

technique(s)

fast flow filtration: suitable
low protein-binding filtration: suitable
pressure filtration: suitable
sterile filtration: suitable (sterilization of tissue culture media, protein solutions or aqueous solutions)

diam.

50 mm

filtration area

19.6 cm2 (3 in2)

housing diam.

62 mm

inlet to outlet H

96 mm , including bell

volume

4000-8000 mL

matrix

Express PLUS

pore size

0.22 μm

input

tissue culture medium
aqueous solution(s)

fitting

inlet stepped hose barb (1/4-1/2 in, with Female Luer slip interior)
outlet filling bell

shipped in

ambient

General description

The bi-directionally supported Millex-GP50 filter is a sterilizing filter for aqueous solutions.It removes microorganisms, particles, precipitates, and undissolved powders largerthan 0.22 micron (μm). The sterile Millex-GP50 filter is non-pyrogenic and non-toxic. Thissingle-use product consists of a 0.22 μm membrane filter sealed in an acrylic housing.

Application

Sterile filtration of tissue culture media, additives,buffers, and water.

Preparation Note

  • For use with peristaltic pump, a pump drive and pump head that delivers a constant speed of 60 revolutions per minute (rpm) is recommended. This generates an average flow rate of 100 mL/min.
  • Recommended tubing: 4-9.5 mm I.D. silicone rubber or latex tubing

Other Notes

  • For use with peristaltic pump, a pump drive and pump head thatdelivers a constant speed of 60 revolutions per minute (rpm) is recommended. This generates anaverage flow rate of 100 mL/min.
  • Recommended tubing: 4-9.5 mm I.D. silicone rubber or latex tubing

Legal Information

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millex is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Customers Also Viewed

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service