A colourimetric sensor capable of simultaneously measuring oxidative status (OS) in terms of the hazard produced by reactive oxygen species (ROS) and antioxidant activity (AOA) in regard to ROS-scavenging ability of antioxidant compounds was developed. The coloured cationic semi-quinone derivatives, caused by ROS oxidative degradation of N,N-dimethyl-p-phenylene diamine hydrochloride (DMPD) in pH 5.7 acetate-buffered medium, were formed in solution and immobilized on a perfluorosulfonate-based Nafion membrane. ROS, namely hydroxyl (·OH) and superoxide (O2(·-)) radicals, were produced by Fenton/UV and xanthine/xanthine oxidase methods, respectively. The pink-coloured, (+)-charged chromophore (referred to as DMPD-quinone or DMPDQ), resulting from the reaction between DMPD and ROS, could be completely retained on the solid membrane sensor by electrostatic interaction with the anionic sulfonate groups of Nafion. After equilibration, the Nafion membrane surface was homogeneously coloured enabling an absorbance measurement at 514 nm, while the aqueous phase completely lacked colour. Antioxidants, when present, caused an absorbance decrease on the membrane due to their ROS scavenging action, giving rise to less DMPDQ production. The absorbance decrease on the sensor was linearly dependent on antioxidant concentration over a reasonable concentration range, enabling the simultaneous determination of OS and AOA-against ROS. The proposed antioxidant sensing method was tested in synthetic and real antioxidant mixtures, and validated against standard antioxidant capacity assays (i.e. ABTS and CUPRAC) for a variety of polyphenolic and antioxidant compounds. The dynamic linear ranges of antioxidants with the DMPD sensor in protection against hydroxyl and superoxide radicals generally varied within the micromolar to a few tens of micromolar concentration interval over one order-of-magnitude. Choosing three representative compounds in the high (epigallocatechin gallate), medium (quercetin) and low (p-coumaric acid) molar absorptivity range, the detection limits ranged within the concentration intervals of 0.2-0.9 μM, 0.3-0.8 μM, and 4-14 μM, respectively, depending on the radical scavenged.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Hydrochloric acid, puriss., 24.5-26.0%
USP
Acetylcysteine, United States Pharmacopeia (USP) Reference Standard
Supelco
Quercetin, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glutathione, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Naringenin, natural (US), 98%
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Hydrogen chloride solution, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Quercetin, ≥95% (HPLC), solid
Supelco
(±)-Naringenin, analytical standard
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
p-Coumaric acid, ≥98.0% (HPLC)
Sigma-Aldrich
Ammonium acetate, Molecular Biology, ≥98%
Sigma-Aldrich
Hydrochloric acid solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Neocuproine, ≥98%
Sigma-Aldrich
Hydrochloric acid, 36.5-38.0%, BioReagent, Molecular Biology
Sigma-Aldrich
Copper(II) chloride dihydrate, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
(±)-Naringenin, ≥95%
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Copper(II) chloride dihydrate, 99.999%
Sigma-Aldrich
Ammonium acetate, BioUltra, ≥99.0%
Supelco
Ammonium acetate, LiChropur, eluent additive for LC-MS
Millipore
Hydrogen peroxide solution, 3%, suitable for microbiology
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Hydrochloric acid solution, ~6 M in H2O, for amino acid analysis
Supelco
Hydrogen chloride – ethanol, ~1.25 M HCl, derivatization grade (GC derivatization), LiChropur
Supelco
Acetic acid, analytical standard
Sigma-Aldrich
Copper(II) chloride dihydrate, ≥99.95% trace metals basis
Sigma-Aldrich
(−)-Epicatechin gallate, ≥98% (HPLC), from green tea