Saltar al contenido
Merck

Saltar a

11982

Adsorbente de polímero poroso TENAX®

matrix Tenax TA, 60-80 mesh, bottle of 10g

para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
A ustedes/SKUDisponibilidadPrecio

Acerca de este artículo

UNSPSC Code:
23201100
NACRES:
NB.21
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Nombre del producto

Adsorbente de polímero poroso TENAX®, matrix Tenax TA, 60-80 mesh, bottle of 10 g

agency

suitable for EPA 601

Quality Segment

form

solid

packaging

bottle of 10 g

parameter

350 °C temp. limit

surface area

~35 m2/g

matrix

Tenax TA

particle size

60-80 mesh

density

~0.25 g/mL (free fall density)

General description

Los polímeros porosos Tenax, basados en el óxido de 2,6-difenil-p-fenileno, se utilizan ampliamente como adsorbentes en aplicaciones tanto de recogida de aire como de trampa y purga. Su estructura única proporciona características alternativas y deseables de adsorción/desorción en comparación con otros polímeros porosos.

Para obtener más información acerca de cualquiera de nuestros adsorbentes, visite sigma-aldrich.com/adsorbents

Application

El adsorbente de polímero poroso TENAX® puede utilizarse para el muestreo adsortivo de:
  • Compuestos orgánicos volátiles (VOC) en diferentes microentornos antes de su determinación mediante desorción térmica de paso corto (SPTD) y cromatografía de gases-espectrometría de masas (GC-MS).
  • Hidrocarburos C 7-C26 en muestras de aire ambiente y VOC en muestras de aire de la sala de trabajo antes de su análisis por TD seguido de análisis por GC.

Legal Information

Tenax is a registered trademark of Buchem B.V.

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
11049-U12168-U20331
surface area

~35 m2/g

surface area

~25 m2/g

surface area

~35 m2/g

surface area

~550 m2/g

particle size

60-80 mesh

particle size

20-35 mesh

particle size

60-80 mesh

particle size

80-100 mesh

form

solid

form

solid

form

solid

form

solid

matrix

Tenax TA

matrix

Tenax GR

matrix

Tenax TA (refined)

matrix

Porapak Q

packaging

bottle of 10 g

packaging

bottle of 500 g

packaging

bottle of 100 g

packaging

bottle of 75 cc

density

~0.25 g/mL (free fall density)

density

~0.40 g/mL (free fall density)

density

-

density

~0.34 g/mL (free fall density)


Still not finding the right product?


pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Clase de almacenamiento

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves



Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. Hello, I have a question regarding the use of Tenax as sampling medium. Acc. to DIN ISO 16000-6, VOCs in air can be determined using Tenax TA. Can you tell me whether Tenax TA can also be used to determine VOCs from CO2 or NOX gases?

    1 answer
    1. The Tenax® Porous Polymer Adsorbent can be used for sampling volatile organic compounds from air and gas samples; therefore, it is applicable for determining VOCs from CO2 or nitrogen dioxide gases.

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. Can tenax be restored in laboratory oven at 40 *C temperature?

    1 answer
    1. The Tenax® Porous Polymer Adsorbent can be regenerated by hot-methanol extraction.

      Helpful?

  5. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  6. What solvents can be used for chemical desorption for Product No. 11982, Tenax TA 60-80 mesh?

    1 answer
    1. Common solvents like alcohols, ethers, hydrocarbons, and aqueous hydrochloric acid/sodium hydroxide can be used.  Don't use chlorinated hydrocarbons like dichloromethane, aromatics like xylene and carbon disulfide. All other solvents not mentioned can be used after checking solubility.

      Helpful?

Reviews

No rating value

Active Filters