For the S2GPU11RE and all Stericup/Steritop products, these are designed to be one time use only. We have not studied the effects of autoclaving or reusing this on the plastic.
Größe auswählen
| Packungsgröße | SKU | Verfügbarkeit | Preis |
|---|---|---|---|
| 12 ea | Warenkorb auf Verfügbarkeit prüfen | € 368,00 |
Über diesen Artikel
Quality Level
material
polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing
sterility
sterile
product line
Stericup®
feature
hydrophilic
packaging
pack of 12 ea
parameter
45 °C max. temp.
description
2.4 mL (hold-up volume)
technique(s)
sterile filtration: suitable
H
319 mm
diam.
13.5 cm
filter capacity
1000 mL
filter diam.
73 mm
filtration area
40 cm2
matrix
Express PLUS™
pore size
0.22 μm pore size
fitting
inlet funnel, outlet flask (Receiver)
shipped in
ambient
storage temp.
no temp limit
General description
Die Stericup® und Steritop® Systeme für die Sterilfiltration verwenden zuverlässige Hochleistungsmembranen für die optimale Sterilfiltration von Laborreagenzien, Puffern und Medien. Diese Einheiten bieten hervorragende Durchfluss- und Durchsatzraten mit geringer unspezifischer Bindung und ein stabiles Design mit Kippschutz.
Diese Stericup® Membranfiltereinheit aus Polyethersulfon (PES) mit einer Porengröße von 0,22 μm besteht aus einem 1000-ml-Flaschenaufsatz mit einer 1000-ml-Auffangflasche und einem Deckel für Verarbeitung und Lagerung.
Application
- Gewebekulturmedien +/- Additive
- Puffer
- Biologische Lösungen
Features and Benefits
- Der Schnellverschluss-Filtertrichter wird mit nur einer Vierteldrehung von der Auffangflasche—getrennt, was die Wahrscheinlichkeit eines Verschüttens verringert und die Handhabung auf dem Labortisch oder unter dem Abzug erleichtert.
- Die fettgedruckte Produktkennzeichnung auf dem Steritop® Filtertrichter zeigt deutlich die Membraneigenschaften einschließlich Zusammensetzung und Porengröße an und ermöglicht so eine unmittelbare, anwendungsgerechte Produktauswahl.
- Der Deckel mit Klickverschluss und Flansch hat eine spezielle Form für einen sicheren Griff unter nassen oder trockenen Bedingungen.—Die taktile Rückmeldung bestätigt den sicheren Verschluss. Damit wird die Möglichkeit eines Verschüttens oder einer Kontamination des sterilisierten Inhalts verringert.
- Die große mattierte Beschriftungsfläche auf der Auffangflasche und die hellere Deckelfarbe erleichtern die eindeutige Beschriftung für eine verbesserte Lesbarkeit und weniger Unleserlichkeiten.
- Der Deckel mit Klickverschluss kommt auf der Seite zu liegen, um das Risiko einer Kontamination zu vermeiden.
- Die Auffangflaschen sind platzsparend stapelbar.
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| filter capacity 1000 mL | filter capacity 500 mL | filter capacity 150 mL | filter capacity 250 mL |
| pore size 0.22 μm pore size | pore size 0.22 μm pore size | pore size 0.22 μm pore size | pore size 0.22 μm pore size |
| material polyethersulfone membrane, polystyrene funnel(s), polystyrene bottle, polystyrene housing | material polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing | material polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing | material polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing |
| sterility sterile | sterility sterile | sterility - | sterility sterile |
| packaging pack of 12 ea | packaging pack of 12 ea | packaging pack of 12 ea | packaging pack of 12 ea |
| fitting inlet funnel, outlet flask (Receiver) | fitting inlet funnel, outlet flask (Receiver) | fitting inlet funnel, outlet flask (Receiver) | fitting inlet funnel, outlet flask (Receiver) |
Still not finding the right product?
Explore all of our products under Millipore® Stericup® Schnellverschluss-Vakuumfiltrationssystem
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Artikel
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Select the right sterile filter by media, volume, and application.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Verwandter Inhalt
Learn how to effectively filter fetal bovine serum (FBS) using Stericup® Quick Release vacuum filtration devices, including flow test data and analysis.
This article shows that a PES membrane containing Stericup Quick Release filter provides an alternative for the pluripotent expansion of embryonic stem cells.
Cell culture media expertise accelerates lab-grown meat and seafood industry with animal-free formulations.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| S2GPU11RE | 04054839116506 |
-
Can the bottle be autoclaved and reused after storage? I understand that the filter is temperature-sensitive, but what about the bottle itself?
1 answer-
Helpful?
-
-
Is there an integrity test available for the S2GPU11RE?
1 answer-
No, an integrity test is not available for the S2GPU11RE.
Helpful?
-
-
Are Stericup® and Steritop® filters GMP-certified?
1 answer-
No, Stericup® and Steritop® devices are not GMP-approved.
Helpful?
-
-
What is the chemical compatibility of the various Stericup® and Steritop® filters?
What is the chemical compatibility of the various Stericup® and Steritop® filters?
1 answer-
Please refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 answer-
No, all Stericup® and Steritop® devices are Research Use Only.
Helpful?
-
-
Can Stericup® bottles be placed inside freezers for long-term storage of media?
1 answer-
You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.
Helpful?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 answer-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)Helpful?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 answer-
Typically 3 years from sterilization.
Helpful?
-
-
What is the maximum vacuum pressure for filtration?
1 answer-
700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)
Helpful?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 answer-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Helpful?
-