GF22261508

Lead

foil, 15mm disks, thickness 0.25mm, as rolled, 99.95%

Sinônimo(s):
PB000381, Lead
Empirical Formula (Hill Notation):
Pb
Número CAS:
Peso molecular:
207.20
Número MDL:
ID de substância PubChem:
NACRES:
NA.23
Preço e disponibilidade não estão disponíveis no momento.

teor

99.95%

forma

foil

Nº de fabricação

Goodfellow, 222-615-08

resistividade

20.65 μΩ-cm

diâmetro × espessura

15 mm × 0.25 mm

pb

1740 °C (lit.)

pf

327.4 °C (lit.)

SMILES string

[Pb]

InChI

1S/Pb

Inchi Key

WABPQHHGFIMREM-UHFFFAOYSA-N

Descrição geral

For updated SDS information please visit www.goodfellow.com.

Informações legais

Product of Goodfellow

Pictogramas

Health hazard

Palavra indicadora

Danger

Frases de perigo

WGK Alemanha

nwg

Ponto de fulgor (ºF)

Not applicable

Ponto de fulgor (ºC)

Not applicable

A Janhom et al.
Dento maxillo facial radiology, 29(1), 20-27 (2000-02-02)
To determine the interaction between image noise and file compression, with special emphasis on the accuracy of caries diagnosis. Fifty-nine bitewing radiographs of patients were taken simultaneously with Ektaspeed Plus (Eastman-Kodak, Rochester, NY, USA) film without lead foil and the...
X A Li et al.
Medical physics, 26(7), 1245-1251 (1999-08-06)
The purpose of this work is to study the dose enhancement by a thin foil (thickness of 0.2-4 mm) of high-Z material in a water phantom, irradiated by high-energy photon beams. EGS4 Monte Carlo technique was used. Perturbations on the...
I Sewerin
Tandlaegebladet, 94(12), 483-486 (1990-09-01)
The lead foil of dental x-ray film packets may cause a number of artifacts; especially well known are the "tractor treads" and "herringbone patterns" following a backward filmpositioning in the patient's mouth. In the present paper a specific and seldomly...
Antonio Lopez Medina et al.
Physics in medicine and biology, 49(1), 17-32 (2004-02-20)
Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage...
George X Ding
Medical physics, 29(11), 2459-2463 (2002-12-05)
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source...

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica

Redes sociais

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

Merck

Pesquisa. Desenvolvimento. Produção.

Somos um fornecedor global líder para o setor de ciências biológicas, com soluções e serviços para pesquisa, desenvolvimento e produção de biotecnologia, além de produção e desenvolvimento de terapias farmacológicas com medicamentos.

© 2021 Merck KGaA, Darmstadt, Alemanha e/ou suas filiais. Todos os direitos reservados.

A reprodução não autorizada de quaisquer materiais deste site é estritamente proibida.