Merck
  • CN1HF1S06
All Photos(1)

CN1HF1S06

Millipore

Polygard® CN Cartridge Filter

pore size 10.0 μm, cartridge nominal length 10 in. (25 cm), Code F (double open end w/flat gaskets)

Synonym(s):
Polygard-CN Cartridge Filter 10 in. 10.0 µm Code F Silicone
eCl@ss:
32031690

material

polypropylene
silicone seal

Nível de qualidade

característica

hydrophilic

manufacturer/tradename

Polygard

parâmetro

4.8 bar max. differential pressure (70 psid) at 25 °C
4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length

10 in. (25 cm)

diâmetro

7.0 cm (2.75 in.)

área de filtração

0.42 m2

Impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables

≤50 mg

tamanho de poro

10.0 μm nominal pore size
10.0 μm pore size

input

sample type liquid

código do cartucho

Code F (double open end w/flat gaskets)

Compare Similar Items

View Full Comparison

1 of 4

This Item
CN03F2V06CN03F2T06CN03F3V06
material

polypropylene , silicone seal

material

fluoroelastomer seal, polypropylene

material

PTFE seal, polypropylene

material

fluoroelastomer seal, polypropylene

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

filtration area

0.42 m2

filtration area

0.84 m2

filtration area

0.84 m2

filtration area

1.26 m2

pore size

10.0 μm nominal pore size, 10.0 μm pore size

pore size

0.3 μm nominal pore size, 0.3 μm pore size

pore size

0.3 μm nominal pore size, 0.3 μm pore size

pore size

0.3 μm nominal pore size, 0.3 μm pore size

cartridge code

Code F (double open end w/flat gaskets)

cartridge code

Code F (double open end w/flat gaskets)

cartridge code

Code F (double open end w/flat gaskets)

cartridge code

Code F (double open end w/flat gaskets)

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

Descrição geral

Device Configuration: Cartridge

Nota de preparo

Sanitization Protocol
30 min with hot water @ 80 °C
Sterilization Method
10 autoclave cycles or SIP @ 126 °C for 30 min

Nota de análise

Gravimetric Extractables: after 24-h soak in water
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L

Outras notas

Directions for Use

  • Organism Retention: Microorganism reduction
  • Mode of Action: Filtration (nominal)
  • Application: BioProcessing
  • Intended Use: Efficient particle and microorganism reduction
  • Instructions for Use: Please refer to the Polygard® and CLARIGARD® Cartridges user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Informações legais

CLARIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

(enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service