Merck

KHGES003FF3

Millipore

Millipore Express® SHC, Opticap® XL Capsule

Opticap® XL 3, sterile, inlet connection diam. 3/4 in., pore size 0.5/0.2 μm, cartridge nominal length 4.7 in. (11.9 cm)

Faça loginto View Organizational & Contract Pricing

Select a Size

Sinônimo(s):
Opticap Sterile XL 300 Millipore Express SHC 0.5/0.2 μm 3/4 in. TC/TC

Materiais

polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal

Nível de qualidade

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

esterilidade

irradiated
sterile

linha de produto

Opticap® XL 3

Características

hydrophilic

manufacturer/tradename

Millipore Express®

Parâmetros

≤1.9 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

Comprimento

11.9 cm (4.7 in.)

cartridge nominal length

4.7 in. (11.9 cm)

Diâmetro

5.6 cm (2.2 in.)

área de filtração

290 cm2

inlet connection diam.

3/4 in.

inlet to outlet W

11.9 cm (4.7 in.)

outlet connection diam.

3/4 in.

Impurezas

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matriz

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

ponto de bolha

≥4000 mbar (58 psig), air with water at 23 °C

conector

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet sanitary flange
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)

Procurando produtos similares? Visit Guia de comparação de produtos

Comparar Itens Semelhantes

Ver Comparação Total

Mostrar diferenças

1 of 4

Este Item
KHGES003FH3KHGES003HB3KHGES003HH3
sterility

irradiated, sterile

sterility

irradiated, sterile

sterility

irradiated, sterile

sterility

irradiated, sterile

product line

Opticap® XL 3

product line

Opticap® XL 3

product line

Opticap® XL 3

product line

Opticap® XL 3

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

filtration area

290 cm2

filtration area

290 cm2

filtration area

290 cm2

filtration area

290 cm2

Descrição geral

Device Configuration: Capsule

Embalagem

Double Easy-Open bag

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Nota de preparo

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análise

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L

Informações legais

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Exoneração de responsabilidade

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Os números dos produtos são combinados com os tamanhos/quantidades da embalagem quando exibidos no site (exemplo: T1503-25G). Por favor, certifique-se você insere APENAS o número do produto no campo Número do produto (exemplo: T1503).

Exemplo

T1503
Número do produto
-
25G
Tamanho/quantidade da embalagem

Exemplos adicionais:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

inserir como 1.000309185)

Está com problemas? Sinta-se à vontade para entrar em contato Assistência Técnica para obter assistência

Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Produtos Aldrich

  • Se encontrar um número de lote como TO09019TO - insira o número do lote 09019TO sem as duas primeiras letras.

  • Se encontrar um número de lote com um código de preenchimento, como 05427ES-021 - insira o número do lote 05427ES sem o código de preenchimento -021.

  • Se encontrar um número de lote com um código de preenchimento como STBB0728K9 - digite o número do lote STBB0728 sem o código de preenchimento K9.

Não encontra o que está procurando?

Em alguns casos, um COA pode não estar disponível on-line. Se a sua pesquisa não encontrou o COA, você pode solicitar um.

Solicitar COA

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica