Pular para o conteúdo
Merck

KHGES03HH3

Millipore Express® SHC 0.5/0.2µm, Opticap® XL 3 Capsule

Fittings 9/16 in. HB/HB, Sterile

Sinônimo(s):

Opticap Sterile XL 3 Millipore Express SHC 0.5/0.2 μm 9/16 in. HB/HB, Millipore Express® SHC, Opticap® XL Capsule

Faça login para ver os preços organizacionais e de contrato.

Selecione um tamanho

Preço e disponibilidade não estão disponíveis no momento.

Sobre este item

UNSPSC Code:
23151806

Pular para

Assistência Técnica
Precisa de ajuda? Nossa equipe de cientistas experientes está à sua disposição.
Estamos aqui para ajudar

Nome do produto

Cápsula Millipore Express® SHC, Opticap® XL, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 9/16 in. Hose BarbOutlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C

material

polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Quality Level

sterility

irradiated, sterile

product line

Opticap® XL 3

feature

hydrophilic

manufacturer/tradename

Millipore Express®

parameter

≤7.6 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 100 psi max. differential pressure (6.9 bar) (intermittent), 2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 25 °C, 6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent), 6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent), 80 psi max. differential pressure (5.5 bar) (continuous), 80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

L

17.3 cm (6.8 in.)

cartridge nominal length

3 in. (7.5 cm)

diam.

10.7 cm (4.2 in.)

filtration area

0.13 m2

inlet connection diam.

9/16 in.

inlet to outlet W

17.3 cm (6.8 in.)

outlet connection diam.

9/16 in.

impurities

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matrix

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

bubble point

≥4000 mbar (58 psig), air with water at 23 °C

fitting

1/4 in. drain/vent hose barb (with double O-ring seal), inlet hose barb, outlet hose barb, (14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Procurando produtos similares? Visita Guia de comparação de produtos

Comparar Itens Semelhantes

Ver Comparação Total

Mostrar diferenças

1 of 4

Este Item
KHGES03TB3KHGES03TH3KHGEA03HH3
pore size

0.5/0.2 μm pore size

pore size

0.5/0.2 μm pore size

pore size

0.5/0.2 μm pore size

pore size

0.5/0.2 μm pore size

filtration area

0.13 m2

filtration area

0.13 m2

filtration area

0.13 m2

filtration area

0.13 m2

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

product line

Opticap® XL 3

product line

Opticap® XL 3

product line

Opticap® XL 3

product line

Opticap® XL 3

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

material

polyester support, polypropylene , polypropylene vent cap, silicone seal, polyethersulfone , polysulfone , polypropylene housing

material

polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal

material

polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal

material

polyethersulfone , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, polysulfone , silicone seal

General description

Device Configuration: Capsule

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 5.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Mantenha-se em conformidade com a GMP usando o programa Emprove®

Acelere a qualificação, mantenha a conformidade e economize tempo com Emprove® Dossiers.

Baixar Dossiers

Nota: você será levado ao EmproveSuite.com. Seu nome de usuário e senha são separados do SigmaAldrich.com e podem ser diferentes.

Registre-se gratuitamente e acesse Emprove® Dossiers em poucos minutos. Faça upgrade de seu plano de assinatura para desbloquear conteúdo avançado e personalizado no Emprove® Suite

Não está encontrando o que está procurando? Visite a página de ajuda do programa Emprove®.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Questions

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica