Merck
Todas as fotos(2)

Documentos

P2C030V01

Millipore

Módulo de ultrafiltração Pellicon® 2 Mini

filtration area 0.1 m2, NMWCO 30 kDa

Faça loginpara ver os preços organizacionais e de contrato

Sinônimo(s):
Pellicon® 2 Mini Ultrafiltration Module PLCTK V 0.1 m2

Materiais

composite regenerated cellulose (CRC)
polypropylene screen
polyurethane adhesive

Nível de qualidade

fabricante/nome comercial

Pellicon®

Parâmetros

3.5 bar max. transmembrane pressure (50 psig) at 30 °C
5-35 L/min recirculation rate at 0.4 bar (6 psi)

técnica(s)

analytical sample preparation: suitable
protein purification: suitable

Altura

2.16 cm (0.85 in.)

Comprimento

21 cm (8.3 in.)

Largura

5.6 cm (2.2 in.)

área de filtração

0.1 m2

membrane nominal area

0.1 m2

extraíveis gravimétricos

≤1500 mg/m2

matriz

Ultracel®

tamanho de poro

30 kDa NMWCO

pH

2-13

Procurando produtos similares? Visit Guia de comparação de produtos

Categorias relacionadas

Comparar Itens Semelhantes

Ver Comparação Total

Mostrar diferenças

1 of 4

Este Item
P2C030C01P2C100V01P2C100C01
Módulo de ultrafiltração Pellicon® 2 Mini filtration area 0.1 m2, NMWCO 30 kDa

P2C030V01

Módulo de ultrafiltração Pellicon® 2 Mini

Módulo de ultrafiltração Pellicon® 2 Mini filtration area 0.1 m2, NMWCO 30 kDa

P2C030C01

Módulo de ultrafiltração Pellicon® 2 Mini

Módulo de ultrafiltração Pellicon® 2 Mini filtration area 0.1 m2, NMWCO 100 kDa

P2C100V01

Módulo de ultrafiltração Pellicon® 2 Mini

Módulo de ultrafiltração Pellicon® 2 Mini filtration area 0.1 m2, NMWCO 100 kDa

P2C100C01

Módulo de ultrafiltração Pellicon® 2 Mini

matrix

Ultracel®

matrix

Ultracel®

matrix

Ultracel®

matrix

Ultracel®

pore size

30 kDa NMWCO

pore size

30 kDa NMWCO

pore size

100 kDa NMWCO

pore size

100 kDa NMWCO

filtration area

0.1 m2

filtration area

0.1 m2

filtration area

0.1 m2

filtration area

0.1 m2

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

parameter

3.5 bar max. transmembrane pressure (50 psig) at 30 °C, 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

3.5 bar max. transmembrane pressure (50 psig) at 30 °C, 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

3.5 bar max. transmembrane pressure (50 psig) at 30 °C, 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

3.5 bar max. transmembrane pressure (50 psig) at 30 °C, 5-35 L/min recirculation rate at 0.4 bar (6 psi)

Descrição geral

The Pellicon® 2 Ultrafiltration PLCTK Mini Cassette sets the standard in cassette-style tangential flow filtration devices. P2C030V01 was designed with process scale-up and applications development in mind.

Millipore′s PLCTK polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Mini Ultrafiltration Module feature a filtration area of 0.1 m2 with a pore size of 30 kDa NMWCO.

Aplicação

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Características e benefícios

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Prefiltration Rquirements: 100 µm

Nota de análise

Gravimetric Extractables: after a water flush

Informações legais

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 2


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Os documentos relacionados aos produtos que você comprou no passado foram reunidos na Biblioteca de Documentos para sua conveniência.

Visite a Biblioteca de Documentos

Dificuldade em encontrar seu produto ou número de lote?

Os números dos produtos são combinados com os tamanhos/quantidades da embalagem quando exibidos no site (exemplo: T1503-25G). Por favor, certifique-se você insere APENAS o número do produto no campo Número do produto (exemplo: T1503).

Exemplo

T1503
Número do produto
-
25G
Tamanho/quantidade da embalagem

Exemplos adicionais:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

inserir como 1.000309185)

Está com problemas? Sinta-se à vontade para entrar em contato Assistência Técnica para obter assistência

Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Produtos Aldrich

  • Se encontrar um número de lote como TO09019TO - insira o número do lote 09019TO sem as duas primeiras letras.

  • Se encontrar um número de lote com um código de preenchimento, como 05427ES-021 - insira o número do lote 05427ES sem o código de preenchimento -021.

  • Se encontrar um número de lote com um código de preenchimento como STBB0728K9 - digite o número do lote STBB0728 sem o código de preenchimento K9.

Não encontra o que está procurando?

Em alguns casos, um COA pode não estar disponível on-line. Se a sua pesquisa não encontrou o COA, você pode solicitar um.

Solicitar COA

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica