P3B030A01
Cassete Pellicon® 3 com membrana Biomax®
30kDa, A Screen, 0.11 m2
Sinônimo(s):
Pellicon® 3 Cassette with Biomax 30 kDa Membrane, A screen, 0.11 m2
About This Item
Pular para
Materiais
TPE seal
polyethersulfone
polypropylene cap (for end)
polypropylene screen
Nível de qualidade
Características
holdup volume 9 mL (in feed channel)
fabricante/nome comercial
Pellicon®
Parâmetros
30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C
técnica(s)
buffer exchange: suitable
protein purification: suitable (concentration)
Altura
2.16 cm (0.85 in.)
Comprimento
20.6 cm (8.1 in.)
Largura
5.6 cm (2.2 in.)
área da membrana
0.11 m2
extraíveis gravimétricos
≤1500 mg/m2
Matriz
Biomax® (Membrane)
tamanho de poro
30 kDa NMWCO
pH
1-14
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
1 of 4
Este Item | P3B010A01 | P3B030A05 | P3B030A00 |
---|---|---|---|
pore size 30 kDa NMWCO | pore size 10 kDa NMWCO | pore size 30 kDa NMWCO | pore size 30 kDa NMWCO |
technique(s) buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) buffer exchange: suitable, protein purification: suitable (concentration) |
matrix Biomax® (Membrane) | matrix Biomax® (Membrane) | matrix Biomax® (Membrane) | matrix Biomax® (Membrane) |
material TPE seal, polypropylene cap (for end), polyethersulfone , polypropylene screen | material TPE seal, polyethersulfone , polypropylene cap (for end), polypropylene screen | material TPE seal, polyethersulfone , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated) | material TPE seal, polyethersulfone membrane (void free), polypropylene , polypropylene cap (for end), polypropylene screen |
parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C |
feature holdup volume 9 mL (in feed channel) | feature holdup volume 9 mL (in feed channel) | feature holdup volume 69 mL (in feed channel) | feature holdup volume 1.8 mL (in feed channel) |
Descrição geral
The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.
This P3B030A01 Pellicon® 3 ultrafiltration device features a pore size of 30 kDa NMWCO, a Biomax® 30 membrane, and dimensions measuring 2.16 cm (H) x 5.6 cm (W) x 20.6 cm (L).
Características e benefícios
- Rugged & reliable – ideally suited for today′s more demanding filtration processes
- High performance – produces excellent resolution, yields and back-pressure resistance
- Optimum product recovery – thanks to proven membrane technology
- Void-free technology – leading-edge membranes resolve virtually any separation challenge
- Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
- Automated manufacturing – delivers unbeatable performance, consistency and reliability
- Easy installation & care – simple to install and maintain
Outras notas
Nota de análise
Informações legais
Código de classe de armazenamento
8B - Non-combustible corrosive hazardous materials
Classe de risco de água (WGK)
WGK 1
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Active Filters
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica