P3C005C00

Millipore

Cassete Pellicon® 3 com membrana Ultracel®

filtration area 88 cm2, NMWCO 5 kDa

Faça loginpara ver os preços organizacionais e de contrato

Sinônimo(s):
Pellicon® 3 Cassette with Ultracel® 5kDa Membrane, C Screen, 88 cm2
eCl@ss:
32031602
NACRES:
NB.24

Materiais

TPE seal
composite regenerated cellulose (CRC) membrane
polypropylene
polypropylene cap (for end)
polypropylene screen

Nível de qualidade

Características

holdup volume 3.6 mL (in feed channel)

fabricante/nome comercial

Pellicon®

Parâmetros

2.75 bar max. inlet pressure (40 psi) at 50 °C
30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
5.5 bar max. inlet pressure (80 psi) at 40 °C
5.5 bar max. transmembrane pressure (80 psig) at 30 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

técnica(s)

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

Altura

0.8 cm (0.33 in.)

Comprimento

20.6 cm (8.1 in.)

Largura

5.6 cm (2.2 in.)

área de filtração

88 cm2

área da membrana

88 cm2

extraíveis gravimétricos

≤1500 mg/m2

matriz

Ultracel® (Membrane)

tamanho de poro

5 kDa NMWCO

pH

2-13

Condições de expedição

ambient

Categorias relacionadas

Comparar Itens Semelhantes

Ver Comparação Total

Mostrar diferenças

1 of 4

Este Item
P3C030D00P3C030C00P3C010C00
Cassete Pellicon® 3 com membrana Ultracel® filtration area 88 cm2, NMWCO 5 kDa

P3C005C00

Cassete Pellicon® 3 com membrana Ultracel®

Cassete Pellicon® 3 com membrana Ultracel® filtration area 88 cm2, NMWCO 30 kDa

P3C030D00

Cassete Pellicon® 3 com membrana Ultracel®

pore size

5 kDa NMWCO

pore size

30 kDa NMWCO

pore size

30 kDa NMWCO

pore size

10 kDa NMWCO

material

TPE seal, polypropylene , polypropylene screen, composite regenerated cellulose (CRC) membrane, polypropylene cap (for end)

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen

filtration area

88 cm2

filtration area

88 cm2

filtration area

88 cm2

filtration area

88 cm2

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 4-6 L/min-m2 recirculation rate, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

Descrição geral

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.

This P3C005C00 Pellicon® 3 ultrafiltration device features a pore size of 5 kDa NMWCO, a filtration area of 88 cm2, a PLCCC membrane, and dimensions measuring 3.8 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Características e benefícios

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Nota de análise

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Informações legais

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 1


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Os documentos relacionados aos produtos que você comprou no passado foram reunidos na Biblioteca de Documentos para sua conveniência.

Visite a Biblioteca de Documentos

Dificuldade em encontrar seu produto ou número de lote?

Os números dos produtos são combinados com os tamanhos/quantidades da embalagem quando exibidos no site (exemplo: T1503-25G). Por favor, certifique-se você insere APENAS o número do produto no campo Número do produto (exemplo: T1503).

Exemplo

T1503
Número do produto
-
25G
Tamanho/quantidade da embalagem

Exemplos adicionais:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

inserir como 1.000309185)

Está com problemas? Sinta-se à vontade para entrar em contato Assistência Técnica para obter assistência

Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Produtos Aldrich

  • Se encontrar um número de lote como TO09019TO - insira o número do lote 09019TO sem as duas primeiras letras.

  • Se encontrar um número de lote com um código de preenchimento, como 05427ES-021 - insira o número do lote 05427ES sem o código de preenchimento -021.

  • Se encontrar um número de lote com um código de preenchimento como STBB0728K9 - digite o número do lote STBB0728 sem o código de preenchimento K9.

Não encontra o que está procurando?

Em alguns casos, um COA pode não estar disponível on-line. Se a sua pesquisa não encontrou o COA, você pode solicitar um.

Solicitar COA

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica