Merck
Todas as fotos(1)

03558

Supelco

Poly(methyl methacrylate)

analytical standard, for GPC, 2,480,000

Sinônimo(s):
PMMA, Poly(methacrylic acid methyl ester)
Fórmula linear:
[CH2C(CH3)(CO2CH3)]n
Número CAS:
Número MDL:
ID de substância PubChem:
NACRES:
NA.24

Nível de qualidade

100

grau

analytical standard
for GPC

temperatura de autoignição

580 °F

prazo de validade

limited shelf life, expiry date on the label

peso molecular

Mn ~2140000
Mp ~2740000
Mw ~2480000

solubilidade

H2O: insoluble

densidade

1.200 g/cm3

Mw/Mn

~1.16

temperatura de armazenamento

2-8°C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

InChI key

PMAMJWJDBDSDHV-UHFFFAOYSA-N

Procurando produtos similares? Visit Guia de comparação de produtos

Descrição geral

Poly(methyl methacrylate) is a material, which can be used in the fabrication of micro-fluid chips. It can also find applications in nano-transfer printing, since it can act like a macroscopic mediator in order to handle nanoscale building blocks.

Código de classe de armazenamento

11 - Combustible Solids

WGK

nwg

Equipamento de proteção individual

Eyeshields, Gloves, type N95 (US)

Certificado de análise

Insira o número de lote para pesquisar o Certificado de análise (COA).

Certificado de origem

Insira o número de lote para pesquisar o Certificado de origem (COO).

Mais documentos

Quotes and Ordering

Development and spectral characterization of poly (methyl methacrylate)/hydroxyapatite composite for biomedical applications
Chen Y, et al.
Development and spectral characterization of poly (methyl methacrylate)/hydroxyapatite composite for biomedical applications, 18(1), 41-45 (2004)
Creation of nanostructures with poly (methyl methacrylate)-mediated nanotransfer printing
Jiao L, et al.
Journal of the American Chemical Society, 130, 12612-12613 (2008)
Panagiotis Korovessis et al.
Spine, 38(4), 292-299 (2013-02-15)
Prospective, parallel-group, controlled comparative randomized study. This study compares the efficacy in sagittal vertebral height and wedge deformity restoration, polymethylmethacrylate cement leakage safety, and functional outcome of balloon kyphoplasty (BK) versus KIVA (a novel vertebral augmentation technique) implant for the
A T Davis et al.
The British journal of radiology, 86(1027), 20130053-20130053 (2013-05-09)
In the emergency department, patients undergoing lateral lumbar spine radiography examinations are positioned either lying on their side on an X-ray table with the X-ray beam vertical or lying supine on a trolley with the X-ray beam horizontal. The measured
Olivier Dron et al.
Ultrasonics, 53(7), 1280-1287 (2013-05-01)
It is well-known that particles can be focused at mid-height of a micro-channel using Acoustic Radiation Force (ARF) tuned at the resonance frequency (h=λ/2). The resonance condition is a strong limitation to the use of acoustophoresis (particles manipulation using acoustic

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica