Merck
Todas as fotos(1)

A8346

Sigma-Aldrich

ProteoMass ACTH Fragment 18-39 MALDI-MS Standard

vial of 10 nmol, monoisotopic mol wt 2,464.1989 Da

Sinônimo(s):
Adrenocorticotropic hormone fragment 18-39
Número CAS:
Número MDL:
ID de substância PubChem:
NACRES:
NA.24

Nível de qualidade

100

peso molecular

monoisotopic mol wt 2,464.1989 Da

embalagem

vial of 10 nmol

SMILES string

CC(C)CC(NC(=O)C1CCCN1C(=O)C(Cc2ccccc2)NC(=O)C(C)NC(=O)C(CCC(O)=O)NC(=O)C(C)NC(=O)C(CO)NC(=O)C(CCC(O)=O)NC(=O)C(CC(O)=O)NC(=O)C(CCC(O)=O)NC(=O)C(C)NC(=O)CNC(=O)C(CC(N)=O)NC(=O)C3CCCN3C(=O)C(Cc4ccc(O)cc4)NC(=O)C(NC(=O)C(CCCCN)NC(=O)C(NC(=O)C5CCCN5C(=O)C(N)CCCNC(N)=N)C(C)C)C(C)C)C(=O)NC(CCC(O)=O)C(=O)NC(Cc6ccccc6)C(O)=O

InChI

1S/C112H165N27O36/c1-56(2)48-72(100(163)125-70(37-41-86(148)149)97(160)133-77(111(174)175)51-63-24-14-11-15-25-63)129-103(166)79-28-20-46-138(79)109(172)75(49-62-22-12-10-13-23-62)131-93(156)61(9)121-95(158)68(35-39-84(144)145)123-92(155)60(8)122-102(165)78(55-140)134-98(161)71(38-42-87(150)151)126-101(164)74(53-88(152)153)128-96(159)69(36-40-85(146)147)124-91(154)59(7)120-83(143)54-119-94(157)73(52-82(115)142)130-104(167)80-29-21-47-139(80)110(173)76(50-64-31-33-65(141)34-32-64)132-107(170)89(57(3)4)135-99(162)67(27-16-17-43-113)127-106(169)90(58(5)6)136-105(168)81-30-19-45-137(81)108(171)66(114)26-18-44-118-112(116)117/h10-15,22-25,31-34,56-61,66-81,89-90,140-141H,16-21,26-30,35-55,113-114H2,1-9H3,(H2,115,142)(H,119,157)(H,120,143)(H,121,158)(H,122,165)(H,123,155)(H,124,154)(H,125,163)(H,126,164)(H,127,169)(H,128,159)(H,129,166)(H,130,167)(H,131,156)(H,132,170)(H,133,160)(H,134,161)(H,135,162)(H,136,168)(H,144,145)(H,146,147)(H,148,149)(H,150,151)(H,152,153)(H,174,175)(H4,116,117,118)

InChI key

ZYDMZKPAPSZILB-UHFFFAOYSA-N

Amino Acid Sequence

Arg-Pro-Val-Lys-Val-Tyr-Pro-Asn-Gly-Ala-Glu-Asp-Glu-Ser-Ala-Glu-Ala-Phe-Pro-Leu-Glu-Phe

Descrição geral

The single peptide or protein standard is used to calibrate and test matrix assisted laser desorption ionization (MALDI) mass spectrometers. Adrenocorticotropic hormone (ACTH) is synthesized from its precursor pro-opiomelanocortin (POMC). It is released from anterior pituitary gland in response to corticotropin-releasing hormone (CRH) from hypothalamus.

Aplicação

Peptide calibration standard for MALDI-MS instruments; 1 vial contains 10 nmols.
ProteoMass ACTH fragment 18-39 MALDI-MS standard has been used as a peptide calibration standard for matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry (MS) instruments.

Ações bioquímicas/fisiológicas

Adrenocorticotropic hormone (ACTH) stimulates the synthesis and release of glucocorticoids and androgens through cAMP-dependent by a G-protein coupled receptor in adrenal gland. Overproduction of ACTH leads to marked skin pigmentation.

Armazenamento e estabilidade

Each standard is stored at room temperature and is shipped at ambient temperature. Standard stock solutions can be frozen in aliquots, but should not be subjected to more than 3 freeze-thaw cycles. Standard solutions are recommended for use for no longer than one month after reconstitution.

Informações legais

ProteoMass is a trademark of Sigma-Aldrich Co. LLC

Código de classe de armazenamento

11 - Combustible Solids

WGK

WGK 3

Ponto de fulgor (ºF)

Not applicable

Ponto de fulgor (ºC)

Not applicable

Equipamento de proteção individual

Eyeshields, Gloves, type N95 (US)

Certificado de análise

Insira o número de lote para pesquisar o Certificado de análise (COA).

Certificado de origem

Insira o número de lote para pesquisar o Certificado de origem (COO).

Endocrinology (2001)
Patient Education: A Practical Approach (2001)
Salivary peptidome profiling for diagnosis of severe early childhood caries.
Sun X, et al.
Journal of Translational Medicine, 14(1), 240-240 (2016)
Jessica L Costa et al.
General and comparative endocrinology, 136(1), 12-16 (2004-02-26)
alpha-Melanocyte stimulating hormone (MSH) and adrenocorticotropin (ACTH)1-24, the minimal ACTH sequence required for full activity, differ only by the 10 C-terminal amino acids of ACTH1-24. Interestingly, these ten C-terminal residues have been highly conserved throughout vertebrate evolution. To understand the
D Vieau et al.
The Journal of clinical endocrinology and metabolism, 79(5), 1503-1506 (1994-11-01)
POMC processing is frequently altered in ACTH-secreting nonpituitary tumors in which intermediate lobe-like peptides such as corticotropin-like intermediate lobe peptide (CLIP) are occasionally generated. In rodent pituitaries, the exclusive presence of prohormone convertase PC2 in the melanotrophs of the intermediate

Artigos

Ultra-Pure MALDI Matrices

One of the most important aspects of our ultra-pure MALDI matrix substances is their ability to dissolve rapidly and completely; a brief vortex mixing is typically sufficient.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica