Skip to Content
MilliporeSigma
All Photos(4)

Key Documents

310697

Sigma-Aldrich

Cellulose

microcrystalline, powder, 20 μm

Synonym(s):

Cellulose powder, Cotton linters

Sign Into View Organizational & Contract Pricing

Select a Size

50 G
$66.90
500 G
$109.00
1 KG
$175.00

$66.90


Please contact Customer Service for Availability

Request a Bulk Order

Select a Size

Change View
50 G
$66.90
500 G
$109.00
1 KG
$175.00

About This Item

CAS Number:
EC Number:
MDL number:
UNSPSC Code:
12162002
NACRES:
NA.23

$66.90


Please contact Customer Service for Availability

Request a Bulk Order

form

microcrystalline
powder

Quality Level

particle size

20 μm

pH

5-7 (11 wt. %)

bulk density

0.5 g/mL (25°C)

SMILES string

O1[C@H](C(C(C(C1CO)O)O)O)O[C@@H]2C(OC(C(C2O)O)O)CO

InChI

1S/C12H22O11/c13-1-3-5(15)6(16)9(19)12(22-3)23-10-4(2-14)21-11(20)8(18)7(10)17/h3-20H,1-2H2/t3?,4?,5?,6?,7?,8?,9?,10-,11?,12+/m1/s1

InChI key

GUBGYTABKSRVRQ-WFVLMXAXSA-N

Looking for similar products? Visit Product Comparison Guide

Application

Bulking agent, opacifier, anti-caking agent, extrusion aid and stabilizer for foams and emulsions.
High purity cellulose powders for partition chromatography.

Features and Benefits

Amorphous regions are hydrolyzed leaving crystalline microfibrils. Forms thixotropic gels, good thermal stability.

Storage Class Code

11 - Combustible Solids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Marco Mattonai et al.
Bioresource technology, 270, 270-277 (2018-09-18)
A combined study of crystallinity index (CI), degree of polymerisation (DP) and thermal stability of cellulose was carried out for monitoring the effect of ball-milling. DP and CI are two fundamental quantities that describe the physico-chemical behaviour of cellulose. Milling
Reza Amin et al.
Micromachines, 11(6) (2020-07-01)
To transform from reactive to proactive healthcare, there is an increasing need for low-cost and portable assays to continuously perform health measurements. The paper-based analytical devices could be a potential fit for this need. To miniaturize the multiplex paper-based microfluidic
Hui Wang et al.
Chemical Society reviews, 41(4), 1519-1537 (2012-01-24)
Utilization of natural polymers has attracted increasing attention because of the consumption and over-exploitation of non-renewable resources, such as coal and oil. The development of green processing of cellulose, the most abundant biorenewable material on Earth, is urgent from the
Edmond Lam et al.
Trends in biotechnology, 30(5), 283-290 (2012-03-13)
Nanocrystalline cellulose (NCC), a rod-shaped nanoscale material with exceptional strength and physicochemical properties, can be prepared from inexpensive renewable biomass. Besides its potential use as a reinforcing agent for industrial biocomposites, pristine NCC exhibits low toxicity and poses no serious
Nadav Sorek et al.
The Journal of biological chemistry, 289(50), 34911-34920 (2014-10-22)
Mutations in the Arabidopsis COBRA gene lead to defects in cellulose synthesis but the function of COBRA is unknown. Here we present evidence that COBRA localizes to discrete particles in the plasma membrane and is sensitive to inhibitors of cellulose

Questions

1–4 of 4 Questions  
  1. When I checked the SDS, the cellulose content was less than 100%. What is the exact purity of the cellulose?

    1 answer
    1. The purity of this product has not been determined. However, as this material is prepared from wood, residual elements remaining from the manufacturing process may be present. In addition, the maximum allowable moisture content is 5.0% and is reported on the lot specific Certificate of Analysis.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. Does the particle size refer to the length or diameter? Are these particles predominantly spherical or cylindrical?

    1 answer
    1. The particle size and morphology are not determined for this product. Semi-spherical particles may be assumed. Historical information indicates particles are <50 μm with an average size of 20 μm. The morphology may be confirmed by the end user via microscopy.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service