Accéder au contenu
MilliporeSigma
  • Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Online background cleanup followed by high-performance liquid chromatography with tandem mass spectrometry for the analysis of perfluorinated compounds in human blood.

Journal of separation science (2014-11-12)
Liangpo Liu, Jianwen She, Xueqin Zhang, Jie Zhang, Meiping Tian, Qingyu Huang, Syed Ali Musstjab Akber Shah Eqani, Heqing Shen
RÉSUMÉ

In this study, a novel method for the analysis of perfluorinated compounds in whole blood has been developed and validated. The method was developed by using a conventional reversed-phase C18 column as a trapping column for the elimination of background contamination and high-performance liquid chromatography with tandem mass spectrometry for the target compounds analysis. The trapping column provided fast online separation of the background contamination of perfluorinated compounds. In this developed method, the limits of detection for different perfluorinated compounds ranged from 0.06 to 0.14 ng/mL. It is notable that the limit of detection (0.07 ng/mL) for perfluorooctanoic acid was improved significantly after the elimination of background contamination. The method was also validated in terms of sensitivity, accuracy, and precision. The recoveries ranged from 66.8 to 111.9%, with relative standard deviations from 2.1 to 15.3%. Our preliminary data suggest that the novel method based on trapping column cleanup followed by high-performance liquid chromatography with tandem mass spectrometry could be applied in studies on the human exposure to perfluorinated compounds.

MATÉRIAUX
Numéro du produit
Marque
Description du produit

Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
tert-Butyl méthyl éther, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
tert-Butyl méthyl éther, ACS reagent, ≥99.0%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
tert-Butyl méthyl éther, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Supelco
Acétate d′ammonium, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Acide heptafluorobutyrique, 98%
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Perfluorooctanoic acid, 95%
Sigma-Aldrich
Méthanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Zirconyl chloride octahydrate, reagent grade, 98%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acétate d′ammonium, Molecular Biology, ≥98%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
tert-Butyl méthyl éther, reagent grade, ≥98%
Supelco
Acide heptafluorobutyrique, suitable for ion chromatography, ≥99.5% (GC)
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Acétate d′ammonium solution, Molecular Biology, 7.5 M
Sigma-Aldrich
tert-Butyl méthyl éther, anhydrous, 99.8%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
tert-Butyl méthyl éther, puriss. p.a., ≥99.5% (GC)
Supelco
Méthanol, analytical standard
Sigma-Aldrich
Acétate d′ammonium, 99.999% trace metals basis