Direkt zum Inhalt
Merck

34860

Sigma-Aldrich

Methanol

Methanol
1 of 3 reviewers received a sample product or took part in a promotion

≥99.9%, suitable for immunofluorescence, HPLC

Synonym(e):

Methylalkohol

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CH3OH
CAS-Nummer:
Molekulargewicht:
32.04
Beilstein:
1098229
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116105
PubChem Substanz-ID:
NACRES:
NA.21
Assay:
≥99.9%
Methode(n):
HPLC: suitable
immunofluorescence: suitable
Anwendung(en):
food and beverages
bp:
64.7 °C (lit.)
Dampfdruck:
410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Produktbezeichnung

Methanol, suitable for HPLC, ≥99.9%

Dampfdichte

1.11 (vs air)

Qualitätsniveau

Dampfdruck

410 mmHg ( 50 °C)
97.68 mmHg ( 20 °C)

Assay

≥99.9%

Form

liquid

Selbstzündungstemp.

725 °F

Expl.-Gr.

36 %

Methode(n)

HPLC: suitable
immunofluorescence: suitable

Verunreinigungen

≤0.0005% non-volatile matter
≤1 ppb fluorescence (quinine) at 254 nm
≤1 ppb fluorescence (quinine) at 365 nm
<0.03% water (Karl Fischer)

Abdampfrückstand

<0.0005%

Farbe

APHA: ≤10

Brechungsindex

n20/D 1.329 (lit.)

bp

64.7 °C (lit.)

mp (Schmelzpunkt)

−98 °C (lit.)

Dichte

0.791 g/mL at 25 °C (lit.)

λ

neat

UV-Absorption

λ: 205 nm Amax: ≤1.00
λ: 210 nm Amax: ≤0.60
λ: 220 nm Amax: ≤0.30
λ: 230 nm Amax: ≤0.20
λ: 235 nm Amax: ≤0.10
λ: 240 nm Amax: ≤0.10
λ: 260 nm Amax: ≤0.04
λ: 280 nm Amax: ≤0.01
λ: 400 nm Amax: ≤0.01

Anwendung(en)

food and beverages

Format

neat

SMILES String

CO

InChI

1S/CH4O/c1-2/h2H,1H3

InChIKey

OKKJLVBELUTLKV-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Die thermochemische Umwandlung von Methanol in C2-C10-Kohlenwasserstoffe in Gegenwart von Zeolithen mit formselektiven Eigenschaften wurde beschrieben.[1] Seine Oxidation an Ru-Pt-Katalysatorsystemen durch Ruthenium-Adatome wurde postuliert.[2]
Methanol ist ein organisches Lösungsmittel, das aus Synthesegas in Gegenwart von CuO/ZnO/Al2O3-Katalysatoren synthetisiert werden kann.[3] Aufgrund seines hohen H/C-Verhältnisses, seiner geringen Neigung zur Rußbildung, seiner relativ niedrigen Reformierungstemperatur und seinem flüssigen Zustand bei Raumtemperatur ist es ein idealer Kandidat als Wasserstoffquelle in der Brennstoffzellentechnologie.[4][5] In einer Direktmethanolbrennstoffzelle (DMFC) wird Methanol mit Luft oxidiert, um elektrischen Strom zu erzeugen. Die aus Methanol mit dem Methanol-zu-Olefin-Verfahren (MTO) gebildeten Olefine (Ethylen oder Propylen) können eine Alternative zu Öl und Gas bei der Herstellung von Kohlenwasserstoffbrennstoffen darstellen.[6]

Anwendung

Methanol (MeOH) wird für Immunfluoreszenzstudien mit Komplettpräparaten aus Embryonalgewebe verwendet.[7]
Es kann in den folgenden Studien verwendet werden:
  • Fibroblasten-Koloniebildungstest (CFU-F-Assay) mit mononukleären Zellen aus Knochenmark.[8]
  • Als Lösungsmittel für die Herstellung von Hyphenextrakten aus Aspergillus zur Bestimmung von Gliotoxin durch Umkehrphasen-HPLC.[9]
  • Immunfluoreszenzstudien.[10]
  • Zusammensetzung des Eluenten für die Isolierung von Nukleotiden und ihren Abbauprodukten mit Ionenpaar-Umkehrphasen-HPLC.[11]
Methanol kann als mobile Phase in der Umkehrphasen-HPLC eingesetzt werden.[12]

Verpackung

Angaben zur Herstellung

Produkt gefiltert durch einen 0,2 μm-Filter

Sonstige Hinweise

Wichtiger Hinweis
  • Die Artikelnummer 34860-4X2.5L wird eingestellt. Bestellen Sie bitte stattdessen die Einzelflasche 34860-2.5L, die physikalisch identisch ist und exakt dieselben Spezifikationen aufweist.
  • Die Artikelnummer 34860-6X1L wird eingestellt. Bestellen Sie bitte stattdessen die Einzelflasche 34860-1L, die physikalisch identisch ist und exakt dieselben Spezifikationen aufweist.

Empfohlene Produkte

LiChropur-Reagenzien sind ideal für die HPLC- oder LC-MS-Analyse

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Zielorgane

Eyes,Central nervous system

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 2

Flammpunkt (°F)

49.5 °F - closed cup

Flammpunkt (°C)

9.7 °C - closed cup


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

High-performance liquid chromatography of thiols and disulfides: dinitrophenol derivatives.
Fariss MW and Reed DJ.
Methods in Enzymology, 143, 101-109 (1987)
Mehmet Nuri Atalar et al.
Life sciences, 231, 116577-116577 (2019-06-19)
Galectin-3 is associated with the process of inflammation and fibrosis. The aim of this study was both to evaluate of galectin-3, methylated arginines and hs-CRP in subjects with type 2 diabetes and prediabetes and to investigate a relation between serum
Catalytic carbon dioxide hydrogenation to methanol: A review of recent studies.
Jadhav SG, et al.
Chemical Engineering Research and Design, 92(11), 2557-2567 (2014)
Jonas Ahnfelt-Rønne et al.
The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society, 55(9), 925-930 (2007-05-05)
We have developed a wholemount immunofluorescence protocol for the simultaneous detection of up to three proteins in mouse and chicken embryos. Combined with Murray's clearing reagent (BABB) and microscope objectives with long working ranges and high numerical apertures mounted on
Beyond oil and gas: the methanol economy.
Olah GA.
Angewandte Chemie (International Edition in English), 44(18), 2636-2639 (2005)

Artikel

HPLC-DAD workflow analyzes 14 cannabinoids in hemp extracts in 10 minutes using Chromolith columns for robust performance.

Substances are said to be miscible in one another if they dissolve to form a uniform solution. Bookmark or download our miscibility table for common lab solvents.

Stoffe gelten als miteinander mischbar, wenn sie sich zu einer einheitlichen Lösung auflösen. Setzen Sie ein Lesezeichen oder laden Sie unsere Tabelle zur Mischbarkeit für gängige Laborlösungsmittel herunter.

LC-MS/MS-based determination of 19 sulfonamides, 13 quinolones, and 3 tetracycline drug residues in pork meat samples using Supel™ Swift HLB for extraction.

Alle anzeigen

Verwandter Inhalt

ZipTip® micro-SPE pipette tips are used as a single-step desalting, concentration, and purification tool for complex samples before mass spec analyses.

Questions

1–7 of 7 Questions  
  1. Product 34860 has an unpleasant fishy odor. What are the possible causes of this odor? Can we still use the product despite the odor?

    1 answer
    1. The distinctive smell is caused by the presence of triethylamine. Even a small amount of TMA, slightly above 50 ppb, can give the entire product its characteristic odor. Despite the odor, the product can still be used.

      Helpful?

  2. What apparatus do you recommend for HPLC solvent filtration?

    1 answer
    1. The Sigma-Aldrich Vacuum Filtration Assembly gives you all the components you need including: funnel top, fritted glass funnel support, filtration flask, aluminum clamp, and silicone stopper.  The Acrodisc Syringe Filters offer high quality filtration for analytical samples, certified for HPLC to ensure low extractable and available in a broad range of membranes to meet sample compatibility requirements.

      Helpful?

  3. What are the options for drying solvents?

    1 answer
    1. Sigma-Aldrich offers a full range of high-purity solvents with extremely low water levels specifically manufactured for moisture sensitive Organic and Biotech applications.  Sigma-Aldrich also carries various drying agents such as molecular sieves, which are typically compatible with organic solvents.

      Helpful?

  4. Can you recommend a Solvent Extractor for organics from aqueous solution?

    1 answer
    1. Solvent extractors are often used for the quantitative extraction of organics from aqueous solutions and separations in immunoassays. The MIXXOR system has been applied successfully in many laboratory solvent extraction operations and is ideal for the rapid screening of alternative solvents for specific extraction problems.

      Helpful?

  5. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  6. Why on occasion does Product 34860, Methanol, have an unusual odor? Does it affect the product purity or performance?

    1 answer
    1. Industry research has indicated that unusual odors in methanol are a common problem and stem from low - level mercaptans and / or amines found in the natural gas raw materials used in production. Odors from these types of compounds can be noticeable at low part per million (ppm) levels and have not been shown to have any negative impact on product performance at these concentrations.

      Helpful?

  7. Who do I contact about larger solvent volume needs?

    1 answer
    1. Email us at [email protected] or visit Sigma-Aldrich Fine Chemicals for development and manufacturing-scale inquiries: [email protected]

      Helpful?

Reviews

1 of 3 reviewers received a sample product or took part in a promotion

Active Filters

  1. 3 Ratings-Only Reviews

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.