Merck
  • 2160
All Photos(5)

2160

Millipore

Autofluorescence Eliminator Reagent

Autofluorescence Eliminator Reagent for IHC.

Synonym(s):
fluorescence IHC counter stain
eCl@ss:
42029053

form

liquid

packaging

pkg of 50 mL

manufacturer/tradename

Chemicon®

technique(s)

immunohistochemistry: suitable

shipped in

ambient

Compare Similar Items

View Full Comparison

1 of 4

This Item
A4108NIST1932790326P
vibrant-m

NIST1932

Fluorescein solution

form

liquid

form

liquid

form

-

form

powder

packaging

pkg of 50 mL

packaging

-

packaging

pkg of 3 x 2 mL

packaging

pkg of 1 × 10 mg (790326P-10mg)

manufacturer/tradename

Chemicon®

manufacturer/tradename

-

manufacturer/tradename

NIST®

manufacturer/tradename

Avanti Polar Lipids 790326P

technique(s)

immunohistochemistry: suitable

technique(s)

-

technique(s)

-

technique(s)

transfection: suitable

shipped in

ambient

shipped in

-

shipped in

-

shipped in

dry ice

General description

Ready-to-use for application in fluorescence microscopy procedures. With increasing age, the autofluorescent pigment lipofuscin accumulates in the cytoplasm of many cell types, including neurons. The presence of lipofuscin granules can complicate the use of fluorescence microscopy in the central nervous system because of its broad excitation and emission spectra, which overlaps with those of most commonly used fluorophores. The Autofluorescence Eliminator Reagent will reduce or eliminate lipofuscin-like autofluorescence without adversely affecting other fluorescent label in sections of human, monkey or rat neural tissue as well as other tissues.

Application

Fluorescence immunohistochemistry counterstain.

PROTOCOL:

1.After immunofluorescence histochemistry, the sections are immersed in PBS for 5 min.·

2.Sections are immersed in 70% ethanol for 5 min.·

3.Sections are immersed in Autofluorescence Eliminator Reagent for 5 min.

4.Sections are immersed in three changes of 70% ethanol for 1 min. each time.·

5.Sections are mounted using an antifading solution (e.g. DABCO, non-xylene-based).



Note: Reagent will block all fluorescence if incubation is too long; length of incubation time and number of 70% ethanol washes can be altered and optimized for various tissues and fluorescent antibody probes. In some instances the reagent can be applied prior to immunofluorescence, however in most cases better results are obtained when used as we direct above (use after immunofluorescence procedures are completed).



Optimal time of incubation with the Autofluorescence Eliminator Reagent should be determined by the end user for each sample.

Absorption maximum: 595-605

Physical form

Liquid in 70% ethanol containing no preservatives. Store at room temperature in the dark.

Storage and Stability

When stored at room temperature, this reagent is stable up to the expiration date printed on the label. Do not freeze or expose to elevated temperatures.

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Signal Word

Danger

Hazard Statements

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - Muta. 2 - STOT SE 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

60.8 - 68.0 °F

Flash Point(C)

16 - 20 °C


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

(enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service