Passa al contenuto
Merck

Vai a

57330-U

Supporto per fibra SPME

greener alternative

for use with Manual Sampling, pk of 1

Sinonimo/i:

Supporto per fibra per microestrazione in fase solida

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Cambia visualizzazione
Taglio della confezioneSKUDisponibilitàPrezzo

Informazioni su questo articolo

NACRES:
NB.21
UNSPSC Code:
41115724
Prezzi e disponibilità al momento non sono disponibili
Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti


packaging

pk of 1

Quality Level

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

technique(s)

solid phase microextraction (SPME): suitable

compatibility

for use with Manual Sampling

greener alternative category

General description

Ci impegniamo a fornire prodotti verdi alternativi che soddisfino almeno uno dei 12 principi della chimica verde. Questo è un prodotto specifico per la tecnica di microestrazione in fase solida (SPME) La microestrazione in fase solida (SPME) è una delle tecnologie verdi di preparazione del campione per l′analisi, in quanto è una tecnica di estrazione che non richiede solventi e le fibre SPME sono riutilizzabili; in più, produce una quantità minima di scarti e per questo rispecchia i principi “Prevenzione” e “Solventi e ausiliari più sicuri”. Per maggiori informazioni, fate clic qui.
Il supporto protegge la fibra rivestita e controlla l′esposizione della fibra durante l′adsorbimento e il desorbimento dell′analita. Il supporto è riutilizzabile indefinitamente e accoglie il gruppo della fibra sostituibile. Chi utilizza questo prodotto per la prima volta deve ordinare sia il supporto sia il gruppo della fibra.

Supporto per fibra per il campionamento manuale

Una guida di profondità regolabile posiziona la fibra per il campionamento e per la corretta collocazione nella zona riscaldata della porta di iniezione della GC. È possibile bloccare la fibra nella posizione esposta.

Supporto per fibra per campionamento automatico o analisi HPLC

Usare questo supporto per fibra con un autocampionatore Varian 8100/8200 o con la nostra interfaccia SPME/HPLC. Per il funzionamento con l′autocampionatore Varian è necessario un kit di aggiornamento SPME. Per informazioni relative ai requisiti del sistema rivolgersi alla Varian Instrument Division.

Supporto per fibra per CTC CombiPAL/CombiPAL-xt e Gerstel MPS2

Application

The SPME Fiber Holder is designed for manual sampling, allowing precise control over the extraction process. It facilitates the integration of sampling, extraction, concentration, and sample introduction into a single solvent-free step. This reduces the need for complex, multi-step procedures and minimizes the use of organic solvents. The holder is compatible with various fiber coatings, making it suitable for a wide range of analytical applications.

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 1

Questo articolo
5733157356-U57347-U
SPME Fiber Holder for use with Manual Sampling, pk of 1

Supelco

57330-U

SPME Fiber Holder

SPME Fiber Holder for use with Non-CTC CombiPAL™ Type Autosamplers, pk of 1

Supelco

57331

SPME Fiber Holder

SPME Inlet Guide

Supelco

57356-U

SPME Inlet Guide

SPME Fiber Holder for use with CTC CombiPAL, Gerstel MPS2 Autosamplers, pk of 1

Supelco

57347-U

SPME Fiber Holder

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

compatibility

for use with Manual Sampling

compatibility

for use with Non-CTC CombiPAL Type Autosamplers

compatibility

-

compatibility

for use with CTC CombiPAL, Gerstel MPS2 Autosamplers

greener alternative category

Aligned,

greener alternative category

, Aligned

greener alternative category

, Aligned

greener alternative category

, Aligned

packaging

pk of 1

packaging

pk of 1

packaging

-

packaging

pk of 1

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

technique(s)

solid phase microextraction (SPME): suitable

Quality Level

100

Quality Level

-

Quality Level

100

Quality Level

100


Still not finding the right product?

Explore all of our products under Supporto per fibra SPME




Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti


Protocolli

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

SPME enables rapid, sensitive GC/MS analysis of residual solvents in hemp extract, ensuring accuracy and efficiency.

SPME offers efficient sample preparation for analyzing terpene/terpenoid profiles in plant essential oils using automation.

Visualizza tutti i protocolli

Articoli

A throughput HS-SPME-GC-MS method to analyze volatile compounds in Perilla leaves at low extraction temperatures using four different SPME fibers.

The work describes the development of an HS-SPME-GC-MS method to determine 2-chloroethanol as a marker of fumigant ethylene oxide in different kinds of sesame seed samples.

A direct immersion SPME method using a new overcoated SPME fiber was developed for the extraction of pesticides from pureed prune baby food.

Visualizza tutti gli articoli

Contenuto correlato

La microextraction en phase solide (SPME) est une technique de préparation d'échantillons sans solvant, qui se sert de fibres enrobées pour extraire les analytes d'intérêt de l'échantillon avant analyse par GC ou HPLC.


Pawliszyn, Janusz
Solid Phase Microextraction: Theory and Practice, 264-264 (1997)
Pawliszyn, Janusz
Applications of Solid Phase Microextraction, 674-674 (1999)
Abdelhamid Neggad et al.
Chemistry & biodiversity, 16(10), e1900267-e1900267 (2019-08-17)
The volatile composition of seven honey samples collected from various regions of Algeria and feeding on different plants have been determined. The Headspace Solid-Phase MicroExtraction (HS-SPME) coupled with Gas Chromatography-Mass Spectrometry (GC/MS) was used to achieve the purpose. In this



Numero articolo commerciale globale

SKUGTIN
57330-U04061835552931
Y000219404065265653121

Questions

1–6 of 6 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What GC injection septa should be used when using the SPME Fiber Holder, Product 57330-U?

    1 answer
    1. We recommend the use of molded Thermogreen LB-2 septa with an injection hole.

      Helpful?

  4. Can I put the SPME Fiber Holder, Product 57330-U, in the oven for conditioning?

    1 answer
    1. No, the barrel is made of a black polymeric material and it will melt.

      Helpful?

  5. Can I use the SPME Fiber Holder, Product 57330-U, with any GC model?

    1 answer
    1. This SPME holder is designed to be used with manually with any GC having an appropriate, straight inlet liner.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters