The human panel HNABTMAG-68k follows the Tau standard with isoform Tau441. Both the capture and detection immunogens used are also Tau441. Cross reactivity for other isoforms has not been tested.
About This Item
Skip To
Product Name
MILLIPLEX® Human Neuroscience Panel, Configurable Human Amyloid Beta and Tau 4-Plex Panel, allows quantitative multiplex detection of multiple analytes simultaneously
Quality Level
species reactivity
human
packaging
pkg of 1 ea
manufacturer/tradename
Milliplex®
assay range
accuracy: 109%
(Spike recovery for Aβ1-42)
accuracy: 91%
(Spike recovery for pTau181)
accuracy: 98%
(Spike recovery for tTau)
sensitivity: 1.5 pg/mL
(pTau181; MinDC+2SD)
sensitivity: 10.2 pg/mL
(Aβ1-40; MinDC+2SD)
sensitivity: 14.2 pg/mL
(tTau; MinDC+2SD)
sensitivity: 2.5 pg/mL
(Aβ1-42; MinDC+2SD)
standard curve range: 0.7-500 pg/mL
(pTau181)
standard curve range: 11-8000 pg/mL
(tTau)
standard curve range: 2-2000 pg/mL
(Aβ1-42)
standard curve range: 21-15000 pg/mL
(Aβ1-40)
inter-assay cv: <15%
intra-assay cv: <10%
technique(s)
multiplexing: suitable
input
cerebrospinal fluid(s) (CSF)
detection method
fluorometric (Luminex® xMAP® technology)
shipped in
wet ice
storage temp.
2-8°C
1 of 4
This Item | HNPMAG-35K | HNDG3MAG-36K | APOMAG-62K |
|---|---|---|---|
| species reactivity human | species reactivity human | species reactivity human | species reactivity human |
| assay range accuracy: 109% | assay range accuracy: 98-118% | assay range accuracy: 108% | assay range accuracy: 85% |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable |
| shipped in wet ice | shipped in wet ice | shipped in wet ice | shipped in wet ice |
Legal Information
Application
Disclaimer
Features and Benefits
General description
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
wgk
WGK 3
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Protocols
A stem cell culture protocol to generate 3D NSC models of Alzheimer’s disease using ReNcell human neural stem cell lines.
Related Content
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
Learn how multiplex detection of Alzheimer’s disease biomarkers, using the MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel, allows for a different perspective on neurodegenerative disease research.
Neuroscience multiplex assays, such as MILLIPLEX® multiplex assays, enable simultaneous measurement of neuroscience-related biomarkers to gain a better picture of neurodegenerative diseases, neurological disorders, and neuropeptide/neurohormone signaling.
Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.
-
Can you provide information on the specificity or cross reactivity of Total Tau in the human HNABTMAG-68K?
1 answer-
Helpful?
-
-
Can the Human Amyoid Beta / Tau (HNABTMAG-68K) Milliplex kit, which currently only lists CSF as a sample type, be used with serum/plasma samples?
1 answer-
The HNABTMAG-68K Milliplex kit currently only lists cerebrospinal fluid (CSF) as a sample type. When serum/plasma samples were tested with this kit, a strong matrix effect was observed. As the kit was not validated for serum/plasma, the appropriate Serum Matrix for use could not be ascertained. Furthermore, the expected trend for Amyloid β40 and Amyloid β42 in serum/plasma was not observed.
For serum/plasma samples, we recommend using the validated ELISA kits for Amyloid β40 and 42 (EZHS and EZH42) as they are the preferred assays. Additionally, we offer a Total Tau ELISA (RAB1085).
Helpful?
-
-
Are the antibodies used in the Human Amyloid Beta/Tau (HNABTMAG-68K) kit also able to recognize rat samples?
1 answer-
The AB40 and AB42 antibodies have not been specifically tested for reactivity to rat. However, in a test involving 4 rat serum samples, AB40 was detected in all of the samples, while AB42 was not detectable. Additionally, the capture antibodies for pTau and Total Tau have been found to be reactive to both human and rat, as pTau and Total Tau were detected in 2 out of the 4 rat serum samples tested. It's important to note that the panel has not been tested with rat standards to determine the extent of cross-reactivity.
Helpful?
-
-
What is the recommended concentration of guanidine for Amyloid Beta Immunoassays?
1 answer-
The recommended guanidine concentration for Amyloid Beta Immunoassays should be less than 0.5M in the final sample concentration.
Helpful?
-
-
Could you provide the plate capacity for an LX200 or FM3D instrument when using one box of Sheath Fluid?
1 answer-
The FLEXMAP 3D and LX200 instruments use approximately 10 mL of sheath per sample run when running a 96-well plate and the xPONENT protocol is set to aspirate 50 µL per sample. Therefore, to acquire one 96-well plate, the instruments will use approximately 1L of sheath fluid.
Helpful?
-
-
Is it possible to add other analytes to the Human Amyloid Beta / Tau Panel (HNABTMAG-68K) as SPR kits?
1 answer-
Additional analytes cannot be added to the AB/Tau panel due to differences in the assay procedure. The detection antibody is added at the primary incubation, whereas the other panels have the detection added after the primary incubation.
Helpful?
-
-
How should the plate for the complete Milliplex assay in Sheath Fluid be stored if it can't be read for a couple of hours?
1 answer-
The plate can be stored at 4°C without shaking for up to 24 hours. Before reading, the plate should be shaken at room temperature for at least 20 minutes to bring it back to ambient temperature.
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service