Skip to Content
Merck

Skip To

1.16720

Glucose Test Strips, reflectometric

1-100 mg/L (glucose), REFLECTOQUANT®, for use with RQflex® 20

Synonym(s):

Glucose chemical test strips, Glucose test strip for instrument reader

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
50 tests
Check Cart for Availability
€67.50

About This Item

UNSPSC Code:
41116116
NACRES:
NA.24
eCl@ss:
40050204

€67.50


Check Cart for Availability

​
Request a Custom OrderRequest more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Glucose Test, reflectometric, 1-100 mg/L (glucose), for use with REFLECTOQUANT®

description

quantitative

Quality Segment

analyte chemical class(es)

sugars

measuring range

1-100 mg/L (glucose)

application(s)

beverage testing
food testing
milk and dairy products

compatibility

RQflex® 20, for use with REFLECTOQUANT®

detection method

reflectometric

storage temp.

2-8°C

General description

Method: reflectometric with test strips 1 - 100 mg/l Reflectoquant®
The Reflectoquant Glucose test is suitable for determining glucose in beverages, food and preserves. Furthermore you can use it in fermentation solutions. Under the catalytic effect of glucose oxidase, glucose is converted into gluconic acid lactone. In the presence of peroxidase the hydrogen peroxide formed in the process reacts with an organic redox indicator to form a blue-green dye that is determined reflectometrically. For pre-testing a sample in an economic and quick way to estimate the glucose concentration and a possible dilution factor prior to using this quantitative method we recommend our semi-quantitative MQuant test strip for glucose.

Application


  • Zinc and Silicon Nano-Fertilizers Influence Ionomic and Metabolite Profiles in Maize to Overcome Salt Stress: In this agricultural research, glucose tests are used to monitor the health and metabolic responses of maize to nano-fertilizer treatment, demonstrating the versatility of glucose assays in environmental and plant science applications (Shoukat et al., 2024).

Analysis Note

function control: conforms
Assay
- standard 1:
9 - 11 mg/l
- standard 2: 36 - 44 mg/l
- standard 3: 72 - 88 mg/l

Other Notes

Replaces: 16720; 16720-1

Legal Information

REFLECTOQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
RQFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany


Storage Class

11 - Combustible Solids

WGK

WGK 1


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

54827-17-7

CAS No.


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters