LAGR04TP6
Aervent® 0.2 µm, Optiseal® Cartridge
pore size 0.2 μm, OptiSeal® 4 in., filtration area 0.18 m2, matrix Aervent®
Synonym(s):
Optiseal Aervent Cartridge Filter 0.2 µm hydrophobic
About This Item
Recommended Products
material
PTFE
polypropylene
polypropylene support
silicone seal
Quality Level
sterility
non-sterile
Sterilization Compatibility
steam-in-place compatible
product line
OptiSeal® 4 in.
feature
hydrophobic
manufacturer/tradename
OptiSeal®
parameter
≤6 mL/min nitrogen diffusion at 965 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
0.35 bar max. differential pressure (5 psid) at 135 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
4.1 bar max. differential pressure (60 psid) (Reverse)
4.1 bar max. inlet pressure (60 psi) (Reverse;)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
technique(s)
gas filtration: suitable
L
4 in.
cartridge nominal length
4 in. (10 cm)
filtration area
0.18 m2
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤10 mg/cartridge
matrix
Aervent®
pore size
0.2 μm pore size
input
sample type liquid
bubble point
≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C
cartridge code
not applicable
Looking for similar products? Visit Product Comparison Guide
General description
Packaging
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Preparation Note
80 (40 forward/40 reverse) SIP cycles of 30 min @ 135 °C; 80 autoclave cycles of 30 min @ 135 °C
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Legal Information
Still not finding the right product?
Give our Product Selector Tool a try.
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service