If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf
Seleccione un Tamaño
| A ustedes/SKU | Disponibilidad | Precio |
|---|---|---|
1 L | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 38,20 € |
2.5 L | Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad | 79,50 € |
Acerca de este artículo
38,20 €
Nombre del producto
Metanol, anhydrous for analysis (max. 0.003% H2O)
grade
anhydrous
Quality Segment
vapor density
1.11 (vs air)
vapor pressure
128 hPa ( 20 °C), 410 mmHg ( 50 °C), 97.68 mmHg ( 20 °C)
description
for analytical purposes, for extraction
assay
≥99.9% (GC)
form
liquid
autoignition temp.
725 °F
potency
5628 mg/kg LD50, oral (Rat), 17100 mg/kg LD50, skin (Rabbit)
expl. lim.
36 %
dilution
(for analytical testing)
impurities
≤0.0002 meq/g Alkalinity, ≤0.0005 meq/g Acidity, ≤0.003% Water, ≤0.05% Acetone (GC), ≤0.1% Ethanol (GC)
evapn. residue
≤10 mg/L
color
APHA: ≤10
refractive index
n20/D 1.329 (lit.)
kinematic viscosity
0.54-0.59 cSt(20 °C)
bp
64.7 °C (lit.)
mp
−98 °C (lit.)
transition temp
flash point 9.7 °C
density
0.791 g/mL at 25 °C (lit.)
SMILES string
CO
application(s)
pharmaceutical
format
neat
storage temp.
2-30°C
InChI
1S/CH4O/c1-2/h2H,1H3
InChI key
OKKJLVBELUTLKV-UHFFFAOYSA-N
Application
- Investigación conductométrica de parámetros de asociación de nano MnSO(4) y formación de complejos con glicilglicina en mezclas acuosas y de metanol-agua: parámetros termodinámicos y posibles aplicaciones: en este estudio se exploran las propiedades conductométricas del sulfato de nano manganeso en mezclas acuosas y de metanol-agua, enfatizando los parámetros termodinámicos y las posibles aplicaciones analíticas (Rashad et al., 2024).
- La electrocatálisis potencia la deshidrogenación termocatalítica del metanol para la producción de H(2) y CO de gran pureza: se destaca el papel del metanol en los procesos de deshidrogenación termocatalítica, crucial para la generación de hidrógeno y monóxido de carbono de gran pureza, demostrando su importancia en la síntesis química y la química analítica (Wu et al., 2024).
Analysis Note
Other Notes
1 of 1
Este artículo | |||
|---|---|---|---|
| application(s) pharmaceutical | application(s) - | application(s) food and beverages | application(s) environmental |
| Quality Level 300 | Quality Level 100 | Quality Level 200 | Quality Level 200 |
| grade anhydrous | grade ZerO2® | grade - | grade ACS reagent, anhydrous, reagent grade |
| assay ≥99.9% (GC) | assay 99.8% | assay ≥99.8% (GC) | assay ≥99.8% (GC) |
| form liquid | form liquid | form liquid | form liquid |
| mp −98 °C (lit.) | mp −98 °C (lit.) | mp −98 °C (lit.) | mp −98 °C (lit.) |
Still not finding the right product?
Explore all of our products under Metanol
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
target_organs
Eyes,Central nervous system
Clase de almacenamiento
3 - Flammable liquids
wgk
WGK 2
flash_point_f
49.5 °F - closed cup
flash_point_c
9.7 °C - closed cup
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
67-56-1
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
How can I determine the shelf life / expiration / retest date of this product?
1 respuesta-
¿Le ha resultado útil?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 respuesta-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
¿Le ha resultado útil?
-
-
HI IS this bottle sealed with a rubber seal/septa to keep it dry? So that I have to use a needle to get my methanol?
1 respuesta-
This bottle does not have a septum cap, for which you would need a needle to access. If you are looking for a methanol product which does have a septum cap, please see products 322415 and 322415.