Merck
All Photos(2)

1.50252

Supelco

Purospher® STAR RP-18 endcapped (5 µm) LiChroCART® 250-4

suitable for HPLC

material

stainless steel column

Nivel de calidad

Agency

suitable for USP L1

Línea del producto

Purospher®

característica

endcapped

envase

1 ea of

extensión del etiquetado

17% Carbon loading

parámetro

250 bar pressure
65 °C max. temp.

technique(s)

HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (High)

columna L × D.I.

25 cm × 4 mm

matriz

fully porous particle

grupo activo de la matriz

C18 bonding phase

tamaño de partícula

5 μm

tamaño de poro

120 Å pore size

superficie

330 m2/g

operating pH range

1.5-10.5

técnica de separación

reversed phase

temp. de almacenamiento

no temp limit

Related Categories

Compare Similar Items

View Full Comparison

1 of 4

This Item
1.502501.502701.51460
material

stainless steel column

material

stainless steel column

material

stainless steel column

material

stainless steel column

agency

suitable for USP L1

agency

suitable for USP L1

agency

suitable for USP L7

agency

suitable for USP L1

product line

Purospher®

product line

Purospher®

product line

Purospher®

product line

Purospher®

feature

endcapped

feature

endcapped

feature

endcapped

feature

endcapped

extent of labeling

17% Carbon loading

extent of labeling

17% Carbon loading

extent of labeling

11.2% Carbon loading

extent of labeling

17% Carbon loading

technique(s)

HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (High)

technique(s)

HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (High)

technique(s)

HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (High)

technique(s)

HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (High)

Descripción general

Purospher® STAR [https://www.sigmaaldrich.com/US/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/purospher-star-hplc-and-uhplc-columns] RP-18 end-capped, 5 µm HPLC columns are designed for universal use and allow the separation of basic, neutral, and metal chelating compounds with simple mobile phases and excellent peak symmetry. They are based on ultra-pure fully porous silica particles (Type B). These columns offer outstanding stability from pH 1.5 to 10.5 over a wide temperature range and suitability for up to 100% aqueous mobile phases. Plus, they demonstrate the best all-around retention characteristics, as proven by the Tanaka test. Thanks to these features, Purospher® STAR RP-18 end-capped, 5 µm HPLC columns allow maximum flexibility to use the best chromatographic conditions for any separation including reversed phase. Purospher® STAR RP-18 end-capped, 5 µm LiChroCART® 250-4 is a cartridge column that requires a manuCART cartridge column holder part number 1.51486.0001 [https://www.sigmaaldrich.com/US/en/product/mm/151486]. The manuCART can hold one cartridge column with or without direct integration of a 4-4 mm guard column. The recommended guard column is Purospher®STAR RP-18 end-capped (5 µm) LiChroCART® 4-4 part number 1.50250.0001 [https://www.sigmaaldrich.com/US/en/product/mm/150250]]. LiChroCART® cartridge columns mounted with a manuCART cartridge column holder are hand-tight only and have therefore a maximum pressure stability of 250 bar. For higher pressure stability requirements Purospher® STAR RP-18 endcapped, 5 µm Hibar® RT 250-4 HPLC columns are available part number 1.150037.0001 [https://www.sigmaaldrich.com/US/en/product/mm/150037m].The column dimension of 250 mm length x 4 mm I.D. is the optimal choice for high-resolution HPLC separation of complex samples.Item 1.50252.1003 is a Validation kit containing 3 Purospher® STAR RP-18 endcapped, 5 µm LiChroCART® 250-4 cartridge columns from 3 different base material lots.Learn more about Purospher® STAR HPLC and UHPLC Columns [https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/408/631/puropsher-star-hplc-uhplc-brochure-br4748en-ms.pdf]Learn more about the Supelco® HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide [https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/600/187/hplc-columns-guide-br7614en-ms.pdf]Brochure: A Practical Guide to HPLC - Method Development Guide [https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/446/037/hplc-method-dev-guide-br6818en-ms.pdf]

Aplicación

Intended for the separation of aflatoxins, aldehydes, alkaloids, antibiotics, catecholamines, explosives, oligonucleotides, esters, fat-soluble vitamins, lipids, fatty acids, flavonoids, ketones, nitrosamines, nucleosides, PAHs, PCBs, peptides, pesticides, phenols, phthalates, preservatives, steroids, metabolized steroids, sulfonamides, sweeteners, and water-soluble vitamins.

Características y beneficios

  • Good suitability for LC-MS applications

Nota de análisis

Pressure: ≤ 130 bar
Theoretical Plates (N/m) (Toluene): ≥ 80000
Symmetry (Toluene): 0.8 - 1.4
Capacity factor (Toluene): ≥ 1.5

Información legal

Hibar is a registered trademark of Merck KGaA, Darmstadt, Germany
LICHROCART is a registered trademark of Merck KGaA, Darmstadt, Germany
MANUCART is a trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany
Supelco is a registered trademark of Sigma-Aldrich Co. LLC

Certificate of Analysis

Please enter the Product Number and Lot Number.

Certificate of Quality

Please enter the Product Number and Lot Number.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service