While this product has not been specifically tested for use in Chlorophyll isolation from water samples, a number of publications recommend using a 0.45 µm pore size for this application. Materials range from glass to nitrocellulose. This filter membrane is expected to be suitable for this application.
Seleccione un Tamaño
| Tamaño de envase | SKU | Disponibilidad | Precio |
|---|---|---|---|
| 100 filters | Disponible para enviar HOYdesdeMerck Chemicals and LS SA | 213,00 € |
Acerca de este artículo
213,00 €
Disponible para enviar HOYDetalles
Quality Level
material
mixed cellulose esters (MCE) membrane, plain filter, white filter
agency
in accordance with ASTM® D4807,D4898
sterility
non-sterile
feature
hydrophilic
packaging
pkg of 100 discs
manufacturer/tradename
MF-Millipore™, Millipore
sustainability
Greener Alternative Product
parameter
4 L/min-cm2 air flow rate, 60 mL/min-cm2 water flow rate, 75 °C max. temp.
diam.
47 mm
filter diam.
47 mm
thickness
150 μm
gravimetric extractables
2.5%
color
white
refractive index
n/D 1.51
matrix
MF-Millipore™
pore size
0.45 μm pore size, 79 % porosity
capacity
262 μg/cm2 adsorption capacity (insulin)
bubble point
≥1.8 bar, air with water at 23 °C
greener alternative category
shipped in
ambient
General description
Los filtros MF-Millipore sin surfactante Triton contienen cantidades mínimas de agente humectante y un nivel más bajo de extraíbles que los filtros MF-Millipore convencionales.
Características y beneficios:
- Filtro versátil para aplicaciones de supervisión biológica y medioambiental
- Disponibles en una variedad de tamaños de poro, de colores negro o blanco, con superficie cuadriculada o lisa.
- Compatibles con los métodos de esterilización con óxido de etileno, irradiación gamma y autoclave.
Need a custom membrane filter? Click here to request a custom membrane filter or unique and large package sizes that may not be available via our website.
Application
- Clarificación de disoluciones acuosas
- Eliminación de partículas
- Análisis de partículas
- Análisis microbiológico
- Aislamiento de partículas similvíricas en aguas residuales
- Agua de grado para análisis de microplásticos
- Unión a ácidos nucleicos, incluido el eDNA
Other Notes
- Retención de organismos: microorganismos
- Modo de acción: filtración (exclusión por tamaño)
- Aplicación: Filtración general de laboratorio
- Indicaciones de uso: Retención o eliminación de los contaminantes biológicos
- Instrucciones de uso: La esterilización mediante filtración de un líquido a través de una membrana con un tamaño de poro de 0,2 μm (o menor) elimina eficazmente los contaminantes biológicos, como bacterias, hongos y levaduras. Para la retención selectiva de contaminantes biológicos de mayor tamaño, puede utilizarse filtración de los líquidos a través de membranas con tamaños de poro de 0,45 μm (o mayores) para atrapar y respaldar el crecimiento de los microorganismos para su cultivo y análisis posteriores
- Condiciones de almacenamiento: Guardar en un lugar seco lejos de una fuente de calor
- Condiciones de eliminación: Desechar de acuerdo con la normativa federal, estatal y local aplicable.
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| manufacturer/tradename MF-Millipore™ | manufacturer/tradename MF-Millipore™ | manufacturer/tradename MF-Millipore™ | manufacturer/tradename MF-Millipore™ |
| pore size 0.45 μm pore size, 79 % porosity | pore size 0.45 μm pore size, 79 % porosity | pore size 0.45 μm pore size, 79 % porosity | pore size 0.45 μm pore size, 79 % porosity |
| parameter 4 L/min-cm2 air flow rate, 75 °C max. temp., 60 mL/min-cm2 water flow rate | parameter 4 L/min-cm2 air flow rate, 60 mL/min-cm2 water flow rate, 75 °C max. temp. | parameter 4 L/min-cm2 air flow rate, 60 mL/min-cm2 water flow rate, 75 °C max. temp. | parameter 4 L/min-cm2 air flow rate, 60 mL/min-cm2 water flow rate, 75 °C max. temp. |
| material mixed cellulose esters (MCE) membrane, white filter, plain filter | material mixed cellulose esters (MCE) membrane, plain filter, white filter | material mixed cellulose esters (MCE) membrane, plain filter, white filter | material mixed cellulose esters (MCE) membrane, plain filter, white filter |
| diam. 47 mm | diam. 90 mm | diam. 25 mm | diam. 50 mm |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
Still not finding the right product?
Explore all of our products under Membrana de filtración MF-Millipore™, tamaño de poro 0,45 µm
signalword
Danger
Clase de almacenamiento
4.1B - Flammable solid hazardous materials
hcodes
Hazard Classifications
ED ENV 1 - Flam. Sol. 1
Listados normativos
Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.
9036-19-5
9036-19-5
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Artículos
Validation of Millex® PES syringe filters in PFAS testing of water samples using EPA method 537.1.
Contenido relacionado
Our broad range of the most trusted tools for cell culture includes stringently sourced and tested FBS, established media formulations, and sterile labware. Cutting-edge techniques using stem cells and 3D matrices are enabled by organoids, hydrogels, culture scaffolds, and bioinks for 3D bioprinting.
Número de artículo de comercio global
| SKU | GTIN |
|---|---|
| HAWP04700 | 04053252275180 |
-
Can this filters be used to filter Chlorophyll a for analysis from water samples?
1 respuesta-
¿Le ha resultado útil?
-
-
Is this sterile?
1 respuesta-
This is a non-sterile product. These membranes may be autoclaved at 121°C for 15-20 minutes. Note that the original packaging is not autoclavable. Membranes must be transferred to an autoclave-safe container or wrap. The filters may warp slightly during the autoclave cycle, but will flatten when placed in a filter holder.
¿Le ha resultado útil?
-
-
Can these filters be used for Silt Density Index (SDI) testing? I am thinking mainly regarding the material of the filter, not so much the diameter and pore size (the last two parameters are correct for SDI testing).
1 respuesta-
Both HAWP04700 and HAEP04700 filters can be used for Silt Density Index (SDI) testing.
¿Le ha resultado útil?
-