Milliflip®-HV Non-sterile Vacuum-driven PVDF Filter Unit

Nonsterile, 50 mL process volume, 0.45 µm pore size, PVDF membrane

Sinónimos:

PVDF nonsterile filter unit, tube top vacuum filter


Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

25 EA

138,00 €

138,00 €


Disponible para enviar HOYDetalles


Solicitar una muestra

Acerca de este artículo

NACRES:
NB.24
UNSPSC Code:
41104921
Pore size:
0.45 μm pore size
Packaging:
pack of 25 ea
Material:
PVDF filter membrane
acrylic housing
polypropylene
Sterility:
non-sterile

Saltar a

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Nombre del producto

Milliflip®-HV Non-sterile Vacuum-driven PVDF Filter Unit, Nonsterile, 50 mL process volume, 0.45 µm pore size, PVDF membrane

material

PVDF filter membrane
acrylic housing
polypropylene

sterility

non-sterile

feature

holdup volume 0.6 mL
hydrophilic

packaging

pack of 25 ea

parameter

max. temp. at 45 °C

technique(s)

vacuum filtration: suitable

H

138 mm

capacity

50 mL

diam.

6.4 cm

filter diam.

4 cm

filtration area

7 cm2

funnel capacity

50 mL

matrix

Durapore®

pore size

0.45 μm pore size

fitting

double lead thread inlet (with vacuum port)
double lead thread inlet for 50 mL centrifuge tube

shipped in

ambient

Quality Level

Categorías relacionadas

Application

Nonsterile vacuum filtration of water, buffers and aqueous solutions

Features and Benefits

Eliminates messy sample transfer via simple vacuum-assisted system; attaches to any standard 50 ml centrifuge tube eliminating unnecessary materials and risk of spilage; ideal for nonsterile filtration of aqueous and organic solutions used in analytical sample preparation; convenient blue stand helps to hold the filter unit during filtration;

General description

The Milliflip® filter unit is a disposable, vacuum-driven nonsterile filtration system used in the pre-filtration and clarification of water, buffers and aqueous solutions. It is designed to work with standard 50 mL centrifuge tubes, which eliminates sample transfer.

Legal Information

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MilliFlip is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Preguntas

1–10 de 17 Preguntas  
  1. Can one remove the filter and/or use with an additional filter?

    1 respuesta
    1. These devices are intended for single use only, and the membrane cannot be removed or changed.

      ¿Le ha resultado útil?

  2. Can I use the filter itself for further investigation or is it packed and sealed?

    1 respuesta
    1. These devices are designed to be single use only, and the membrane is not removable/changeable.

      ¿Le ha resultado útil?

  3. Does the tube holder come with it?

    1 respuesta
    1. Yes, this product includes one tube stand per box of 25 devices. Please see the link below to review additional information available in the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/204/618/20767821-ms.pdf

      ¿Le ha resultado útil?

  4. What is a Milliflip™ filter unit?

    1 respuesta
    1. The nonsterile vacuum-driven Milliflip™ filter unit is designed to offer a convenient solution to quickly clarify samples, buffers and reagents prior to analysis.The ready-to-assemble, closed system of the Milliflip™ filtration unit offers an ergonomic design, robust filtration of up to 50 ml, maximizes recovery, saves time, and reduces contamination. There is no sample transfer needed as you can simply filter with a flip of your wrist.

      ¿Le ha resultado útil?

  5. Why is the liquid flowing out the vacuum tubing line?

    1 respuesta
    1. There are two recommendations:
      1. Confirm orientation: This is likely being used upside-down. See user manual for correct orientation.
      2. Make sure to use a trap with filtered line to prevent liquid from entering pump or vacuum set-up (i.e. Millex® FG 50mm Cat. SLFG05010)

      ¿Le ha resultado útil?

  6. What is the maximum centrifugal speed of the conical tube?

    1 respuesta
    1. 5000 x g (Fixed angle 23, 35, 45-degree rotors)

      ¿Le ha resultado útil?

  7. Does Milliflip™ have other options for membrane material besides 0.45 µm Durapore® polyvinylidene fluoride (PVDF)?

    1 respuesta
    1. Milliflip™ is currently only offered in 0.45 µm Durapore® polyvinylidene fluoride (PVDF). However, sterile versions of PES, Nylon and PVDF membranes are available in the Steriflip brand.

      ¿Le ha resultado útil?

  8. What is the minimum volume that can be filtered?

    1 respuesta
    1. Sample volume should be greater than 1-2 mL. Filter unit hold-up and tubes’ residual hold-up volume can be ~0.5 mL. It is best to have entire filter surface covered in liquid

      ¿Le ha resultado útil?

  9. Can I sterilize the Milliflip™ Durapore HV filter?

    1 respuesta
    1. Sterile version of the Durapore-HV filter can be ordered (Steriflip® HV filter Cat. SE1M003M00)

      ¿Le ha resultado útil?

  10. Do I have to use vacuum pressure to filter my sample?

    1 respuesta
    1. Yes, this is a vacuum type of device and processing is performed using vacuum pressure. Many types of vacuum sources may be used including pumps and house vacuum