Merck

P3B050A05

Millipore

Placa Pellicon® 3 con membrana Biomax®

50kDa, A Screen, 0.57 m2

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Sinónimos:
Pellicon® 3 Cassette with Biomax 50 kDa Membrane, A screen, 0.57 m2
eCl@ss:
32031623

Materiales

TPE seal
polyethersulfone
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)

Nivel de calidad

Características

holdup volume 69 mL (in feed channel)

fabricante / nombre comercial

Pellicon®

Parámetros

30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

técnicas

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

Altura

2.4 cm (0.93 in.)

Longitud

20.6 cm (8.1 in.)

Anchura

17.8 cm (7 in.)

área de la membrana

0.57 m2

extraíbles gravimétricos

≤1500 mg/m2

matriz

Biomax® (Membrane)

tamaño de poro

50 kDa NMWCO

pH

1-14

¿Está buscando productos similares? Visit Guía de comparación de productos

Categorías relacionadas

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
P3B010A05P3B050A01P3B030A05
matrix

Biomax® (Membrane)

matrix

Biomax® (Membrane)

matrix

Biomax® (Membrane)

matrix

Biomax® (Membrane)

material

TPE seal, polypropylene screen, polyethersulfone , stainless steel cap (for end; polypropylene-encapsulated)

material

TPE seal, polyethersulfone , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

material

TPE seal, polyethersulfone , polypropylene cap (for end), polypropylene screen

material

TPE seal, polyethersulfone , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

technique(s)

analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

buffer exchange: suitable, protein purification: suitable (concentration)

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 6.9 bar max. inlet pressure (100 psi)

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

feature

holdup volume 69 mL (in feed channel)

feature

holdup volume 69 mL (in feed channel)

feature

holdup volume 9 mL (in feed channel)

feature

holdup volume 69 mL (in feed channel)

Descripción general

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.

This P3B050A05 Pellicon® 3 ultrafiltration device features a pore size of 50 kDa NMWCO, a Biomax® 50 membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Características y beneficios

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Otras notas

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Nota de análisis

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Información legal

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Código de clase de almacenamiento

8B - Non-combustible, corrosive hazardous materials

Clase de riesgo para el agua (WGK)

WGK 1


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Para su comodidad, los documentos relacionados con los productos que usted ha comprado con anterioridad se han recopilado en la Biblioteca de documentos.

Visite la Librería de documentos

¿Le resulta difícil encontrar su producto o lote/número de lote?

Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (ejemplo: T1503).

Ejemplo

T1503
Referencia del producto
-
25G
Tamaño del envase/cantidad

Otros ejemplos

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

introducir como 1.000309185)

¿Tiene algún problema? No dude en ponerse en contacto con nosotros Servicio técnico para asistencia

Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch».

Productos Aldrich

  • Si encuentra un número de lote como TO09019TO, introduzca el número de lote 09019TO sin las dos primeras letras.

  • Si encuentra un número de lote con un código de entrada como 05427ES-021, introduzca el número 05427ES sin el código de entrada -021.

  • Si encuentra un número de lote con un código de entrada como STBB0728K9, introduzca el código de lote STBB0728 sin el código de entrada K9.

¿No ha encontrado lo que estaba buscando?

En algunos casos, puede que un COA no esté disponible en la página web. Si su búsqueda no encontró el COA puede solicitarlo.

Solicitar COA

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico