About This Item
Skip To
Product Name
Vivaspin 20 centrifugal concentrator, MWCO 5 kDa
material
polycarbonate housing
polyethersulfone membrane
description
PES membrane
sterility
non-sterile
feature
holdup volume 20 μL
packaging
package of 12 ea
manufacturer/tradename
Sartorius VS2011
parameter
5 bar max. pressure
8000 × g max. centrifugal force
dead stop volume
50 μL
membrane area
6 cm2
tube size
~50 mL
working volume
20 mL
pore size
5 kDa MWCO
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | Z614602 | Z614645 | Z614629 |
|---|---|---|---|
| material polycarbonate housing, polyethersulfone membrane | material polycarbonate housing, polyethersulfone membrane | material polycarbonate housing, polyethersulfone membrane | material polycarbonate housing, polyethersulfone membrane |
| pore size 5 kDa MWCO | pore size 10 kDa MWCO | pore size 50 kDa MWCO | pore size 30 kDa MWCO |
| parameter 5 bar max. pressure, 8000 × g max. centrifugal force | parameter 5 bar max. pressure, 8000 × g max. centrifugal force | parameter 5 bar max. pressure, 8000 × g max. centrifugal force | parameter 5 bar max. pressure, 8000 × g max. centrifugal force |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| manufacturer/tradename Sartorius VS2011 | manufacturer/tradename Sartorius VS2001 | manufacturer/tradename Sartorius VS2031 | manufacturer/tradename Sartorius VS2021 |
| working volume 20 mL | working volume 20 mL | working volume 20 mL | working volume 20 mL |
General description
Remaining volume is easy to read off the printed scales on the side of the concentrator and the modified dead stop pocket further simplifies direct pipette recover of the final concentrate.
- Vivaspin centrifugal concentrators offer the optimal solution to any concentration or buffer exchange application with their broad range of volume capacities and MWCOs
- Highest flow rates and recoveries are achieved due to their particular vertical membrane design
- Incomparably safe sample handling and convenience is assured by the patented dead-stop technology allowing direct recovery of the concentrate without further re-spin
Note: One step dealing of concentrated sample using diafiltration cup. Gas pressure filtration; for faster processing gas pressure can be combined with centrifugal force.