This product is not suitable for the Karl-Fischer oven method. Standards are available specifically for the oven method. Regional Technical Service can provide assistance with selecting the correct standard.
Sélectionner une taille de conditionnement
113,00 €
141,00 €
113,00 €
Expédition prévue aujourd'huiDétails
A propos de cet article
Passer à
Nom du produit
Water Standard 0.01 %, Reference Material for coulometric Karl Fischer Titration 1 g ≙ 0.1 mg H2O Aquastar®
grade
reference material
agency
ISO 17025
vapor pressure
10 hPa ( 20 °C)
product line
Aquastar®
form
liquid
autoignition temp.
465 °C
expl. lim.
1.7-7.5 % (v/v)
reaction suitability
reaction type: water standard for Karl Fischer titration
packaging
ampule of 10 × 8 mL
technique(s)
Karl-Fischer titration: suitable, titration: suitable
bp
137 °C/1013 hPa
mp
-34 °C (xylene)
transition temp
flash point 25 °C
solubility
0.2 g/L
density
0.86 g/mL at 20 °C
format
single component solution
storage temp.
15-25°C
Quality Level
1 of 4
Cet article | 1.88051 | 1.88052 | 1.88054 |
|---|---|---|---|
| grade reference material | grade certified reference material | grade certified reference material | grade certified reference material |
| agency ISO 17025 | agency ISO 17025, 17034 | agency ISO (17025, 17034) | agency ISO 17025, 17034 |
| format single component solution | format single component solution | format single component solution | format neat |
| vapor pressure 10 hPa ( 20 °C) | vapor pressure - | vapor pressure - | vapor pressure - |
| product line Aquastar® | product line Aquastar® | product line Aquastar® | product line Aquastar® |
| form liquid | form liquid | form liquid | form solid |
General description
Please visit ISO certificates and Site Quality Self-Assessments to access the current certificates of accreditation.
In our effort to be more sustainable, we′re going digital with COAs-download them directly from our website. Download your certificate at https://www.sigmaaldrich.com/US/en/documents-search to view certified values, including uncertainty and expiry date.
Application
Features and Benefits
- Packed in convenient 8 mL glass ampules. Each box contains 10 single-use ampules
- Supplied with a batch-specific digital certificate of analysis (CoA) having data on exact measured water content of the batch, uncertainty, method of analysis, the NIST batch, and minimum shelf life
- Measured and qualified in an ISO/IEC 17025 accredited laboratory
- Directly traceable to SI unit (kg) and verified by secondary reference standards 2890 from NIST
- Shelf life of 18 months
Packaging
Analysis Note
Legal Information
related product
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3
target_organs
Respiratory system
Classe de stockage
3 - Flammable liquids
wgk
WGK 2
flash_point_f
77.0 °F
flash_point_c
25 °C
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Articles
New Aquastar® Karl Fischer Anolyte for precise and reproducible determination of low water content in the range of 10 ppm to 10000 ppm for cells without a diaphragm.
Methods including internal extraction, external extraction, and Karl Fischer oven ensure accurate water content determination by titration.
-
Hallo, ist dieser Standard für die Karl-Fischer Ofenmethode geeignet?
1 réponse-
Utile ?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 réponse-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdfUtile ?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 réponse-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Utile ?
-
-
bonjour, avons nous l'information sur la densité du produits en g/cm3? sur la boite ou sur le CoA? merci ref 1.88050
1 réponse-
As stated in the Properties section of the product page, the material has a density of 0.86 g/mL at 20°C.
Utile ?
-
Filtres actifs
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique