Skip to Content
Merck

Skip To

SCGPCAPRE

Millipore® Stericap™ Plus Vacuum Filter

pore size 0.22 μm, polyethersulfone membrane, pack of 10 ea

Synonym(s):

SteriCap PLUS, universal bottle top sterile filter, universal bottle top vacuum filter, universal bottle top vacuum filtering unit

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
10 ea
Please contact Customer Service for Availability
£217.00

About This Item

UNSPSC Code:
41104914
NACRES:
NB.24
eCl@ss:
32031623

£217.00


Please contact Customer Service for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

polyethersulfone membrane, polyethylene , polypropylene , polystyrene

sterility

sterile

feature

holdup volume 2.7 mL, hydrophilic

packaging

pack of 10 ea

parameter

45 °C max. temp.

technique(s)

sterile filtration: suitable

H

76 mm

diam.

10 cm

filter diam.

73 mm

filtration area

40 cm2

matrix

Express PLUS™

pore size

0.22 μm pore size

fitting

inlet hose barb, outlet bottle top (Universal)

shipped in

ambient

storage temp.

15-25°C

General description

The Stericap PLUS Universal Bottle-Top Filter Device with Millipore Express PLUS membrane provides fast vacuum filtration and low protein binding without the need for a prefilter in most cases. It filters quickly, without clogging, even viscous solutions typical of serum-containing media. This non-cytotoxic, non-pyrogenic device can be used to fill any vacuum-rated bottle or other container with an inner neck diameter of 20 to 67 mm. This allows maximum versatility, capacity, speed, and flowthrough efficiency when you need to filter larger volumes into containers with openings of various sizes.

Features & Benefits:
- Millipore Express PLUS membrane for fastest flow rates and low protein binding

- Fits any vacuum-rated bottle from 20 to 67 mm in diameter for maximum flexibility

- High volume capacity for larger and less frequent preparation steps

- Easy flow control button so the filter can be easily transferred from bottle to bottle without turning off the vacuum each time

- Free of cytotoxic and pyrogenic contaminants for robust cell culture and sensitive downstream applications

Applications:
Sterilization of Aqueous Solutions, Media Preparation, Buffer Preparation

Application

For research use only.

Biochem/physiol Actions

Vacuum

Physical form

Color Code: Clear

Preparation Note

Sterilization Method
Gamma irradiation

Other Notes

Directions for Use

  • Organism Retention: Microorganisms
  • Mode of Action: Filtering
  • Application: Sterile filtration
  • Intended Use: Sterile filtration of laboratory reagents, buffers, and media.
  • Instructions for Use: Please refer to the instructions for use section of Stericup® PLUS user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
STERICAP is a trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
SVHVB1010HAMP29300CFIF01205
description

pore size 0.22 μm, polyethersulfone membrane, pack of 10 ea

description

pore size 0.45 μm, PVDF membrane, capacity 1000 mL, with bell outlet, pack of 10 ea

description

-

description

For use with Milli-Q® Bowl systems

shipped in

ambient

shipped in

ambient

shipped in

-

shipped in

-

packaging

pack of 10 ea

packaging

pack of 10 ea

packaging

pkg of 100 pkg

packaging

pkg of 1 kit

storage temp.

15-25°C

storage temp.

no temp limit

storage temp.

-

storage temp.

-

parameter

45 °C max. temp.

parameter

45 °C max. temp., 3.1 bar max. inlet pressure (45 psi)

parameter

-

parameter

-

feature

holdup volume 2.7 mL, hydrophilic

feature

hydrophilic, holdup volume 2.2 mL

feature

-

feature

-

matrix

Express PLUS™

matrix

Durapore®

matrix

-

matrix

-




Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. Are all GL45 bottles compatible, is there a max liter amount? Are they compatible with the 10LT GL45 bottles as well?

    1 answer
    1. This product is a universal bottle top filter suitable for containers with a neck ID of 20 - 67 mm. There is no threading, the cap is held in place by the vacuum pressure. The volume is dependent upon the type of solution being filtered. A maximum volume has not been determined, but should the membrane become physically fouled, it is no longer usable and must be replaced. A typical volume range of 5 - 10L may be expected when filtering the prepared tissue culture medium.
      See the following link to review a short instructional video on usage of this item:
      https://www.youtube.com/watch?v=kXekb-9w7Yk

      Please see the following link to review the user guide:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/406/550/pr02269w-rev-0920-ms.pdf

      Helpful?

  2. Which bottles are compatible with the Stericap Plus?

    1 answer
    1. GL45 bottles are compatible with the Stericap Plus.

      Helpful?

Reviews

No rating value

Active Filters