Skip to Content
Merck

Skip To

HVLP02500

PVDF Membrane Filter, 0.45 μm Pore Size

greener alternative

Durapore®, filter diam. 25 mm, hydrophilic

Synonym(s):

Durapore® Membrane Filter, 0.45 µm, Hydrophilic PVDF membrane filter discs, Hydrophilic Polyvinylidene fluoride membrane filter discs

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

UNSPSC Code:
40161507
NACRES:
NB.24
eCl@ss:
32031602
Pore size:
0.45 μm pore size, 70 % porosity
Material:
plain white PVDF filter membrane
Feature:
hydrophilic
Diam.:
25 mm
Sterility:
non-sterile
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

plain white PVDF filter membrane

Quality Level

sterility

non-sterile

feature

hydrophilic

manufacturer/tradename

Durapore®, Millipore

sustainability

Greener Alternative Product

parameter

>2.6 mL/min-cm2 water flow rate, 4 L/min-cm2 air flow rate, 85 °C max. temp.

diam.

25 mm

filter diam.

25 mm

thickness

125 μm

gravimetric extractables

0.5%

refractive index

n/D 1.42

matrix

Durapore®

pore size

0.45 μm pore size, 70 % porosity

bubble point

≥1.55 bar, air with water at 23 °C

greener alternative category

shipped in

ambient

General description

Durapore® membranes provide high flow rates and throughput, low extractables and broad chemical compatibility. Hydrophlic Durapore membrane binds far less protein than nylon, nitrocellulose, or PTFE membranes.

Features & Benefits
- Available in several pore sizes (both hydrophilic and hydrophobic varieties) to suit your application needs
- Durapore membrane filters have very low protein binding to minimize interaction with your sample and maximize recovery
Filter Code: HVLP
Filter Type: Screen filter
We are committed to bringing you Greener Alternative Products, which have been re-engineered to enable more sustainable research solutions. The inner & outer boxes containing the membrane discs are made from bio-circular material allocated using the ISCC mass balance approach. Click here for more information.

Application

Clarifying filtration of biological solutions

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: General laboratory filtration
  • Intended Use: Retention or removal of biological contaminants
  • Instructions for Use: Sterilizing filtration of a liquid through a membrane with a 0.2 μm (or smaller) pore size effectively removes biological contaminants, including bacteria, mold and yeast. For the selective retention of larger biological contaminents, liquid filtration through membranes with 0.45 μm (or larger) pore sizes may be used to trap and support microorganism growth for subsequent culture and analysis
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
HVLP04700HVLP09050HVLP14250
diam.

25 mm

diam.

47 mm

diam.

90 mm

diam.

142 mm

material

plain white PVDF filter membrane

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

pore size

0.45 μm pore size, 70 % porosity

pore size

0.45 μm pore size, 70 % porosity

pore size

0.45 μm pore size, 70 % porosity

pore size

0.45 μm pore size, 70 % porosity

parameter

>2.6 mL/min-cm2 water flow rate, 85 °C max. temp., 4 L/min-cm2 air flow rate

parameter

>2.6 mL/min-cm2 water flow rate, 4 L/min-cm2 air flow rate, 85 °C max. temp.

parameter

>2.6 mL/min-cm2 water flow rate, 4 L/min-cm2 air flow rate, 85 °C max. temp.

parameter

>2.6 mL/min-cm2 water flow rate, 4 L/min-cm2 air flow rate, 85 °C max. temp.

manufacturer/tradename

Durapore®, Millipore

manufacturer/tradename

Durapore®, Millipore

manufacturer/tradename

Durapore®, Millipore

manufacturer/tradename

Durapore®, Millipore

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile


Still not finding the right product?


Storage Class

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

了解膜滤器和膜选择注意事项,包括化学相容性、孔径和 MWCO、结合和光学特性,以及用于蛋白质和小分子分析物样品制备、HPLC、LC-MS 和其他分析的可萃取物。

Membrane filters for sample preparation and analysis are discussed, emphasizing chemical compatibility and selectivity.





Questions

  1. Hi Just wondering if this product would be suitable with DMSO filtration? We use HNWP02500 but this product doesn't seems to be available.

    1 answer
    1. Nylon membranes, with lower concentrated DMSO, will be compatible. Once a sample has increased concentration, it is not recommended to use Nylon with DMSO. We have tested 10% DMSO and that is fine to use Nylon. 100% DMSO is not recommended with Nylon membranes.

      Helpful?

Reviews

No rating value

Active Filters