266299

Sigma-Aldrich

powder, ≥99% trace metals basis, <45 μm

Empirical Formula (Hill Notation):
Cr
CAS号:
分子量:
52.00
EC 号:
MDL编号:
PubChem化学物质编号:
NACRES:
NA.22

质量水平

100

测定

≥99% trace metals basis

形式

powder

reaction suitability

core: chromium
reagent type: catalyst

电阻率

12.7 μΩ-cm, 20°C

粒径

<45 μm

bp

2672 °C (lit.)

mp

1857 °C (lit.)

密度

7.14 g/mL at 25 °C (lit.)

SMILES string

[Cr]

InChI

1S/Cr

InChI key

VYZAMTAEIAYCRO-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

storage_class_code

13 - Non Combustible Solids

WGK Germany

WGK 3

闪点(F)

Not applicable

闪点(C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)

分析证书

原产地证书 (CofO)

J A J Vanoirbeek et al.
Journal of toxicology and environmental health. Part A, 66(4), 393-409 (2003-01-30)
Chromium-based catalysts are used for the synthesis of polyethylene, but little is known about the hazard and biomonitoring possibilities of this type of chromium for workers who may be occupationally exposed to such compounds. Therefore, the bioavailability and toxicokinetics of...
B Seifert et al.
Journal of exposure analysis and environmental epidemiology, 10(2), 103-114 (2000-05-03)
The German Environmental Survey (GerES) is a large-scale population study which has repeatedly been carried out in Germany. GerES I was conducted in 1985/1986 followed by GerES IIa in 1990/1991 (West Germany) and GerES IIb in 1991/1992 (East Germany). GerES...
Feng Liu et al.
Scientific reports, 3, 1554-1554 (2013-03-28)
In conventional photostimulable storage phosphors, the optical information written by x-ray or ultraviolet irradiation is usually read out as a visible photostimulated luminescence (PSL) signal under the stimulation of a low-energy light with appropriate wavelength. Unlike the transient PSL, here...
A J Hart et al.
The Journal of bone and joint surgery. American volume, 95(8), 678-685 (2013-04-19)
Determining the relationship between clinical factors and engineering analysis of retrieved hip implants can help our understanding of the mechanism of device failure. This is particularly important for metal-on-metal hip arthroplasties because the most common cause of failure is unexplained....
Carola Lidén et al.
Contact dermatitis, 54(5), 233-238 (2006-05-13)
There is a great need to accurately assess skin exposure to contact allergens. We have developed a technique for assessment of skin exposure to nickel, chromium and cobalt using acid wipe sampling by cellulose wipes with 1% nitric acid. Chemical...