所有图片(1)

357251

Sigma-Aldrich

foil, thickness 0.5 mm, ≥99.9% trace metals basis

别名:
Ta
Empirical Formula (Hill Notation):
Ta
CAS号:
分子量:
180.95
EC 号:
MDL编号:
PubChem化学物质编号:
NACRES:
NA.23

质量水平

100

蒸汽压

<0.01 mmHg ( 537.2 °C)

测定

≥99.9% trace metals basis

形式

foil

自燃温度

572 °F

电阻率

13.5 μΩ-cm, 20°C

厚度

0.5 mm

bp

5425 °C (lit.)

mp

2996 °C (lit.)

密度

16.69 g/cm3 (lit.)

SMILES string

[Ta]

InChI

1S/Ta

InChI key

GUVRBAGPIYLISA-UHFFFAOYSA-N

包装

20.8 g in rigid mailer

数量

20.8g = 50×50mm;83.2g = 100×100mm

Storage Class Code

13 - Non Combustible Solids

WGK Germany

nwg

闪点(F)

Not applicable

闪点(C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)

分析证书

原产地证书 (CofO)

Hany A El-Sayed et al.
Nanoscale, 5(4), 1494-1498 (2013-01-23)
Ta oxide nanotubes (NTs) were formed by the anodization of Ta at 15 V in a solution of concentrated sulfuric acid containing 0.8-1.0 M hydrofluoric acid. To study the initial stages of NT formation, FESEM images of samples anodized for...
Thomas Larzon et al.
Vascular, 21(2), 87-91 (2013-03-20)
Control of back bleeding from the hypogastric artery into the aneurysm after endovascular aneurysm repair (EVAR) of a ruptured aorto-iliac aneurysm may be necessary in order to avoid a type II endoleak. It is an emergency situation and selective catheterization...
Orbital ultrasound in the selective screening of a dural-cavernous sinus fistula.
Hamid Shokoohi et al.
European journal of emergency medicine : official journal of the European Society for Emergency Medicine, 20(2), 137-139 (2013-02-26)
S Nag et al.
Journal of the mechanical behavior of biomedical materials, 16, 21-28 (2012-11-10)
Microstructure and mechanical properties of laser deposited complex quaternary Ti-34Nb-7Zr-7Ta (all wt%), an orthopedic load-bearing implant alloy, has been investigated in detail in both as-deposited as well as heat-treated (β-solutionized and quenched) conditions. The difference in stress-strain behavior of this...
J-Y Chun et al.
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 45(2), 141-144 (2013-01-02)
Type 1 endoleaks following endovascular aortic aneurysm repair are associated with poor outcomes and re-intervention is recommended as soon as possible after diagnosis. When standard endovascular or surgical treatment options are unsuitable due to severe co-morbidity or adverse anatomic factors...

技术文章

Biomedical Implant Devices Fabricated from Low Young’s Modulus Titanium Alloys Demonstrating High Mechanical Biocompatibility

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门