Merck
All Photos(1)

1.09213

Millipore

穿孔盖

400 hole x 0.7mm, Aluminium, suitable for portable MAS-100® family and non-lockable ICR contact plates

Synonym(s):
Collectine head, Sieve head, Perforated lid for contact plates

物料

aluminum

Agency

non-compendial

特点

autoclavable
no. of holes 400

包装

pkg of 1 unit

参数

11 m/s impaction speed (at flow rate of 100 L/min)

孔直径

0.7 mm

application(s)

air monitoring
cosmetics
food and beverages
pharmaceutical

相容性

for use with MAS-100 Eco® non-lockable 55 mm contact plates (ICR, RT)
for use with MAS-100 NT® Ex non-lockable 55 mm contact plates (ICR, RT)
for use with MAS-100 NT® non-lockable 55 mm contact plates (ICR, RT)
for use with MAS-100 VF® non-lockable 55 mm contact plates (ICR, RT)

储存温度

2-30°C

Looking for similar products? Visit Product Comparison Guide

Related Categories

Compare Similar Items

View Full Comparison

1 of 4

This Item
1.193631.091951.09088
Perforated Lid 400 hole x 0.7mm, Aluminium, suitable for portable MAS-100® family and non-lockable ICR contact plates

Millipore

1.09213

穿孔盖

Perforated Lid 300 x 0.6 mm, aluminum, edge-protected for MAS-100 NT® and MAS-100 VF®

Millipore

1.19363

穿孔盖

Perforated Lid 400 hole x 0.7mm, Aluminium, for MAS-100 Eco®

Millipore

1.09088

穿孔盖

material

aluminum

material

aluminum lid

material

aluminum lid

material

aluminum lid

feature

autoclavable, no. of holes 400

feature

autoclavable, no. of holes 300

feature

autoclavable, no. of holes 300

feature

autoclavable, no. of holes 400

compatibility

for use with MAS-100 Eco® non-lockable 55 mm contact plates (ICR, RT), for use with MAS-100 NT® Ex non-lockable 55 mm contact plates (ICR, RT), for use with MAS-100 NT® non-lockable 55 mm contact plates (ICR, RT), for use with MAS-100 VF® non-lockable 55 mm contact plates (ICR, RT)

compatibility

configured for MAS-100 NT® (with or without filter), configured for MAS-100 NT® Ex (with or without filter), configured for MAS-100 VF®

compatibility

for use with MAS-100 NT® Ex, for use with MAS-100 VF®, for use with settle plates (ICR, ICRplus, LI)

compatibility

for use with MAS-100 Eco®, for use with MAS-100 Iso MH®, for use with MAS-100 NT® Ex, for use with MAS-100 VF®, for use with settle plates (ICR, ICRplus, LI)

storage temp.

2-30°C

storage temp.

-

storage temp.

no temp limit

storage temp.

no temp limit

agency

non-compendial

agency

non-compendial

agency

non-compendial

agency

non-compendial

packaging

pkg of 1 unit

packaging

-

packaging

pkg of 1 unit

packaging

pkg of 1 unit

一般描述

The Perforated for contact plates is made from anodized aluminum and can be used with MAS-100 NT®, MAS-100 NT® Ex, MAS-100 NT® Ex with Filter, MAS-100 NT® with Filter, MAS-100 Eco®, MAS-100 VF® and non-lockable 55 mm contact plates, e.g. ICR contact plates. The sieve of the perforated lid is at the core of the viable air sampler. Each hole must have an identical diameter and length to accelerate the aspirated air correctly. The impaction speed defines the physical sampling efficiency. The cut-off value D50 (the particle size at which 50% of the particles impact in the agar due to inertia and 50% are exhausted with the airstream) must be identical between holes and between lids. That is why intense quality control of the sieves is performed. The sieve pattern with 400 holes of a diameter of 0.7 mm provides an impaction speed of approximately 11 m/s at a flow rate of 100 l/min. This impaction speed allows a high physical efficiency, meaning a sampling efficiency of more the 50% of small particles at a size of less than 1.6 μm (D50, calculated) while maintaining the viability of microorganisms during impaction on the agar surface (biological efficiency). The perforated lid can be autoclaved and disinfected with all disinfectants compatible to anodized aluminum in order to avoid false positive results in high grade cleanrooms. The sampling efficiency for an instrument must remain identical, irrespective of the lid used. Our perforated lids allow the exchange of several lids with identical sieve pattern on the MAS air sampler without the need of re-calibration. For all MAS-100® instruments with exception of MAS-100 VF® an adapter for contact plates is required in addition. The standard dust cover can be used with this perforated lid.

应用

The perforated lid is used for microbial monitoring of ambient air with portable MAS-100® line with non-lockable contact plates, such as ICR contact plates Microbial air sampling devices are extensively used in Pharmaceutical and Personal care industries as well as in Food, Beverage and Environmental applications.

法律信息

MAS-100 is a registered trademark of MBV AG
MAS-100 Eco is a registered trademark of MBV AG
MAS-100 NT is a registered trademark of MBV AG
MAS-100 VF is a registered trademark of MBV AG