300 x 0.6 mm, aluminum, edge-protected for MAS-100 NT® and MAS-100 VF®

登录to View Organizational & Contract Pricing

Select a Size

别名:
Collection head, Sieve head, Perforated lid

物料

aluminum lid

Agency

non-compendial

特点

autoclavable
no. of holes 300

manufacturer/tradename

MAS-100 NT®
MAS-100 VF®

top thickness

0.6 mm

application(s)

air monitoring
food and beverages
personal care
pharmaceutical

相容性

configured for MAS-100 NT® (with or without filter)
configured for MAS-100 NT® Ex (with or without filter)
configured for MAS-100 VF®
for use with Viable Air Samplers (1.09191)
for use with Viable Air Samplers (1.09194)
for use with Viable Air Samplers (1.17103)
for use with Viable Air Samplers (1.17274)
for use with Viable Air Samplers (1.17275)

正在寻找类似产品? Visit 产品对比指南

比较类似商品

查看完整比较结果

显示差异

1 of 4

此商品
1.091891.090881.09195
Perforated Lid 300 x 0.6 mm, aluminum, edge-protected for MAS-100 NT® and MAS-100 VF®

Millipore

1.19363

穿孔盖

Perforated Lid 300 x 0.6 mm, Stainless steel, edge protected for MAS-100 Iso® line air sampler

Millipore

1.09189

穿孔盖

Perforated Lid 400 hole x 0.7mm, Aluminium, for MAS-100 Eco®

Millipore

1.09088

穿孔盖

feature

autoclavable, no. of holes 300

feature

autoclavable, no. of holes 300 (edge protected)

feature

autoclavable, no. of holes 400

feature

autoclavable, no. of holes 300

compatibility

configured for MAS-100 NT® (with or without filter), configured for MAS-100 NT® Ex (with or without filter), configured for MAS-100 VF®, for use with Viable Air Samplers (1.09191), for use with Viable Air Samplers (1.09194), for use with Viable Air Samplers (1.17103), for use with Viable Air Samplers (1.17274), for use with Viable Air Samplers (1.17275)

compatibility

for use with MAS-100 Iso MH®, for use with MAS-100 Iso NT®, for use with Viable Air Samplers (1.09168), for use with Viable Air Samplers (1.09173), for use with Viable Air Samplers (1.09174), for use with Viable Air Samplers (1.17118), for use with Viable Air Samplers (1.17144), for use with Viable Air Samplers (1.17145), for use with Viable Air Samplers (1.17146), for use with Viable Air Samplers (1.17147), for use with Viable Air Samplers (1.17148), for use with Viable Air Samplers (1.17149), for use with Viable Air Samplers (1.17155), for use with Viable Air Samplers (1.17157), for use with Viable Air Samplers (1.17174), for use with Viable Air Samplers (1.17177), for use with Viable Air Samplers (1.17178), for use with Viable Air Samplers (1.17291), for use with Viable Air Samplers (1.17292), for use with Viable Air Samplers (1.17309), for use with Viable Air Samplers (1.17310), for use with Viable Air Samplers (1.17312), for use with settle plates (ICR, ICRplus, LI)

compatibility

for use with MAS-100 Eco®, for use with MAS-100 Iso MH®, for use with MAS-100 NT® Ex, for use with MAS-100 VF®, for use with Viable Air Samplers (1.09227), for use with settle plates (ICR, ICRplus, LI)

compatibility

for use with MAS-100 NT® Ex, for use with MAS-100 VF®, for use with Viable Air Samplers (1.09191), for use with Viable Air Samplers (1.09194), for use with Viable Air Samplers (1.17103), for use with Viable Air Samplers (1.17274), for use with Viable Air Samplers (1.17275), for use with settle plates (ICR, ICRplus, LI)

agency

non-compendial

agency

non-compendial

agency

non-compendial

agency

non-compendial

manufacturer/tradename

MAS-100 NT®

manufacturer/tradename

-

manufacturer/tradename

-

manufacturer/tradename

-

top thickness

0.6 mm

top thickness

-

top thickness

-

top thickness

-

一般描述

The Perforated lid for MAS-100 NT® (300 x 0.6 mm) is made from anodized aluminum and can be used with the portable the MAS-100 NT® series and MAS-100 VF® microbial air samplers. The sieve of the perforated lid is at the core of the viable air sampler. This version is provided with edge protection in order to protect the dealing surface from scratches and damages and can be used instead of the standard perforated lid, which is supplied with the instrument. Each hole must have an identical diameter and length to accelerate the aspirated air correctly. The 3mm thickness of the perforated sieve guarantee a well-defined impaction jet. The impaction speed defines the physical sampling efficiency. The cut-off value d50 (the particle size at which 50% of the particles impact in the agar due to inertia and 50% are exhausted with the airstream) must be identical between holes and between lids. That is why intense quality control of the sieves is performed. The sieve pattern with 300 holes of a diameter of 0.6 mm provides an impaction speed of approximately 20 m/s at a flow rate of 100 l/min. This impaction speed allows a high physical efficiency, meaning a sampling efficiency of more the 50% of small particles at a size of less than 1.1 μm (d50, calculated, below 0.8 μm in validation studies) while maintaining the viability of microorganisms during impaction on the agar surface (biological efficiency). The validation of physical and biological efficiency has been independently performed for each individual MAS Air sampler model. The perforated lid can be autoclaved and disinfected with all disinfectants compatible anodized aluminum in order to avoid false positive results in high grade cleanrooms. The sampling efficiency for an instrument must remain identical, irrespective of the lid used. Our perforated lids allow the exchange of several lids with identical sieve pattern on the MAS air sampler without the need of re-calibration.

应用

The perforated lid with 300 x 0.6 mm hole sieve is used for microbial monitoring of ambient air with portable MAS-100® microbial air samplers in controlled environments, such as ISO 5 cleanrooms. Microbial air sampling devices are extensively used in Pharmaceutical and Personal care industries as well as in Food, Beverage and Environmental applications.

法律信息

MAS-100 is a registered trademark of MBV AG
MAS-100 NT is a registered trademark of MBV AG
MAS-100 VF is a registered trademark of MBV AG

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门