跳转至内容
Merck

81392

Supelco

聚氯乙烯

Selectophore, high molecular weight

别名:

PVC

登录查看公司和协议定价


About This Item

线性分子式:
(CH2CHCl)n
CAS号:
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

形狀

powder

黏度

2.0-5.0 mPa.s, 3 % in THF(25 °C)

密度

1.4 g/mL at 25 °C (lit.)

SMILES 字串

ClC=C

InChI

1S/C2H3Cl/c1-2-3/h2H,1H2

InChI 密鑰

BZHJMEDXRYGGRV-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

聚氯乙烯 (PVC) 是由氯乙烯单体经聚合反应制得的聚合物。它永远不能这样使用,多与热稳定剂、润滑剂、增塑剂、填充剂和其他添加剂混合使用。由于其良好的耐化学腐蚀性属性,在化工装置的施工和衬砌中得到了广泛的应用。
访问我们的 传感器应用程序门户 了解更多信息。

應用

用它制备了以桑色素为载体的 PVC 膜铝离子选择电位传感器。

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

dust mask type N95 (US), Eyeshields, Gloves


Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

Slide 1 of 7

1 of 7

聚氯乙烯 European Pharmacopoeia (EP) Reference Standard

P2600000

聚氯乙烯

钾离子载体 I Selectophore™, function tested

Supelco

60403

钾离子载体 I

聚(氯乙烯)羧化 Selectophore™, 1.8% carboxyl basis

Supelco

81395

聚(氯乙烯)羧化

聚氯乙烯增塑剂 United States Pharmacopeia (USP) Reference Standard

USP

1544916

聚氯乙烯增塑剂

钠离子载体 X Selectophore™, function tested

Supelco

71747

钠离子载体 X

双(1-丁基戊基)己二酸酯 Selectophore™, ≥98.0%

Supelco

02150

双(1-丁基戊基)己二酸酯

聚氯乙烯 United States Pharmacopeia (USP) Reference Standard

USP

1548076

聚氯乙烯

Poly (vinyl chloride).
Allsopp, Michael W., and Giovanni Vianello.
Ullmann's Encyclopedia of Industrial Chemistry (1992)
Aluminum (III) selective potentiometric sensor based on morin in poly (vinyl chloride) matrix.
Gupta, Vinod K., Ajay K. Jain, and Gaurav Maheshwari.
Talanta, 72.4, 1469-1473 (2007)
Gianluigi Li Bassi et al.
Critical care medicine, 41(2), 518-526 (2012-12-25)
To assess the structural characteristics involved in the design of high-volume low-pressure endotracheal tube cuffs that are associated with fluid sealing effectiveness and to determine the extent of transmitted tracheal pressures upon cuff inflation. In vitro study. Pneumology laboratories. Eight
Michal Ciborowski et al.
Journal of proteome research, 11(12), 6231-6241 (2012-11-15)
Ozonated autohemotherapy (O3-AHT) is a medical approach during which blood obtained from the patient is ozonated and injected back into the body. Despite an increasing number of evidence that O3-AHT is safe, this type of therapy remains controversial. To extend
Jeffrey S Souris et al.
Molecular imaging, 12(1), 28-38 (2013-01-26)
At present, there is considerable interest in the use of in vivo fluorescence and bioluminescence imaging to track the onset and progression of pathologic processes in preclinical models of human disease. Optical quantitation of such phenomena, however, is often problematic

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门