• 主页
  • 查找结果
  • Noncompetitive immunoassay detection system for haptens on the basis of antimetatype antibodies.

Noncompetitive immunoassay detection system for haptens on the basis of antimetatype antibodies.

Clinical chemistry (2015-02-20)
Kazuya Omi, Tsuyoshi Ando, Takuya Sakyu, Takashi Shirakawa, Yoshiaki Uchida, Asako Oka, Nobuyuki Ise, Katsumi Aoyagi, Katsutoshi Goishi
摘要

Small molecules classified as haptens are generally measured by competitive immunoassay, which is theoretically inferior to noncompetitive sandwich immunoassay in terms of sensitivity and specificity. We created a method for developing sandwich immunoassays to measure haptens on the basis of antimetatype antibodies. We generated antimetatype monoclonal antibodies against a hapten-antibody immunocomplex using an ex vivo antibody development system, the Autonomously Diversifying Library (ADLib) system. We selected 2 haptens, estradiol (E2) and 25-hydroxyvitamin D [25(OH)D], as analytes. Sandwich immunoassays for these 2 haptens were developed by use of a 96-well microtiter plate and a fully automated chemiluminescence analyzer, and the performances of these immunoassays were investigated. The developed assays exhibited sensitivity high enough to detect target haptens in serum samples. The limit of detection of the ELISA for E2 was 3.13 pg/mL, and that of the fully automated chemiluminescent enzyme immunoassay (CLEIA) system was 2.1 ng/mL for 25(OH)D. The cross-reactivity with immunoreactive derivatives was effectively improved compared with the competitive assay. The CVs for the sandwich ELISA for E2 were 4.2%-12.6% (intraassay) and 6.2%-21.8% (total imprecision). The CVs for the sandwich CLEIA for 25(OH)D were 1.0%-2.3% (intraassay) and 1.9%-3.5% (total imprecision). In particular, the sandwich CLEIA for 25(OH)D showed correlations of r = 0.99 with both LC-MS/MS and a commercially available (125)I RIA. Our method represents a potentially simple and practical approach for routine assays of haptens, including vitamins, hormones, drugs, and toxins.

材料
货号
品牌
产品描述

Sigma-Aldrich
N,O-双(三甲基甲硅烷基)乙酰胺, synthesis grade, ≥95%
Supelco
25-羟基维生素D3标准液 CRM 溶液, 100 μg/mL in ethanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
25-羟基维生素D3 一水合物, ≥99.0% (HPLC)
Sigma-Aldrich
25-羟基胆钙化醇, ≥98% (HPLC)
Sigma-Aldrich
25-羟基维生素 D3 溶液, 100 μg/mL in ethanol, 98% (CP)
Sigma-Aldrich
25-羟基维生素 D3 溶液, 50 μg/mL in ethanol, 98% (CP)
Sigma-Aldrich
25-羟基维生素 D3 溶液, 5 μg/mL in ethanol, 98% (CP)
Supelco
25-羟基维生素D3标准液 CRM 溶液, 5 μg/mL in ethanol, ampule of 1 mL, certified reference material, Cerilliant®

社交媒体

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

Merck

科研、开发、生产。

作为生命科学行业的全球领先供应商,我们致力于为科研、生物技术开发和生产,以及制药药物疗法开发和生产提供各类解决方案和服务。

© 2021年版权归德国达姆施塔特默克集团(Merck KGaA)及/或其附属公司所有。版权所有。

未经许可,严禁复制本网站上的任何资料。