Select a Size
| Size/SKU | Availability | Price |
|---|---|---|
10 ea | Estimated to ship on14 October 2026fromUPS Healthcare Hungary Zrt. | 188 000 HUF |
About This Item
Quality Segment
material
Nylon 66 adapter (for needle), PVC tubing (double lumen), PVDF membrane, plain filter, stainless steel (for needle), styrene-acrylonitrile (SAN) (for canister)
agency
EP (2.6.1), JP (4.06), USP 71
sterility
sterile; γ-irradiated
feature
Red base canister with single needle for easy access.
manufacturer/tradename
Steritest®
packaging
pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed
parameter
120 mL sample volume (graduation marks at 25, 50, 75 and 100 mL), 3.1 bar max. inlet pressure (45 psi) at 25 °C, 45 °C max. temp.
tubing L
850 mm
color
red Canister Base
matrix
Durapore®
pore size
0.45 μm pore size
input
sample type pharmaceutical(s)
application(s)
pharmaceutical
sterility testing
compatibility
For liquids in ampoules and collapsible bags.
shipped in
ambient
General description
Steritest® NEO is a membrane filtration device for sterility testing of filterable pharmaceutical products. The device simplifies every aspect of testing, from handling to traceability. The closed system minimizes false positives and offers the highest levels of quality and reliability. This device ensures that pharmaceutical products are never exposed to the environment during the testing process. This test system offers an optimized and fully regulatory compliant testing process when used with the Steritest® Symbio pump, specific accessories and high-quality culture media and rinsing fluids. The Steritest® NEO Double Packed Device for Liquids Antibiotics is gamma sterilized and double packed for the quick transfer into sterility testing environments, simplifying decontamination procedures and saving time. A separate vent needle is included for the transfer of the test product, culture media or rinsing buffer. The red canister base indicates low absorption. Durapore® hydrophilic Poly vinylidene fluoride (PVDF) membrane and specific drain design. This optimizes the rinsing of products that inhibit microbial growth.
Application
Features and Benefits
- One-stop-shop for sterility testing with our devices, pumps, media, fluids, and services
- Steritest® devices are manufactured in our Center of Excellence in Molsheim, France, with high-quality control standards maintaining the Certificate of Quality for each lot.
- New needle design
- Smarter workflow
- Completely closed set up
- Consistent performance
- New tubing disconnection tool
Packaging
Legal Information
1 of 1
This Item | |||
|---|---|---|---|
| description For liquids in ampoules and collapsible bags., Red base canister with single needle for easy access., pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed | description For medical devices and collapsible bags., Red base canister provided with 3 needle adapters to connect to a variety of test devices., pkg of 10 blisters per box, Single packed | description For liquids in small vials., Blue base canister with a vented double needle for small vials with septa. | description For liquids in small vials., Blue base canister with a vented double needle for small vials with septa., pkg of 10 blisters per box, Single packed |
| compatibility For liquids in ampoules and collapsible bags. | compatibility for use with Steritest® Symbio LFH Pump Kit (SYMBLFH01), for use with Steritest® Symbio ISL Pump Kit, 2 media (SYMBISL01), For medical devices and collapsible bags., for use with Steritest® Symbio FLEX Pump Kit, 2 media (SYMBFLE01) | compatibility For liquids in small vials. | compatibility for use with Steritest® Symbio FLEX Pump Kit, 2 media (SYMBFLE01), For liquids in small vials., for use with Steritest® Symbio ISL Pump Kit, 2 media (SYMBISL01), for use with Steritest® Symbio LFH Pump Kit (SYMBLFH01) |
| material plain filter, PVDF membrane, Nylon 66 adapter (for needle), styrene-acrylonitrile (SAN) (for canister), stainless steel (for needle), PVC tubing (double lumen) | material plain filter, styrene-acrylonitrile (SAN) (for canister), PVC tubing (double lumen), stainless steel (for needle), PVDF membrane, Nylon 66 adapter (for needle) | material mixed cellulose esters (MCE) membrane, PVC tubing (double lumen), Nylon 66 adapter (for needle), plain filter, styrene-acrylonitrile (SAN) (for canister), stainless steel (for needle) | material mixed cellulose esters (MCE) membrane, PVC tubing (double lumen), plain filter, Nylon 66 adapter (for needle), styrene-acrylonitrile (SAN) (for canister), stainless steel (for needle) |
| packaging pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed | packaging pkg of 10 blisters per box, Single packed | packaging pkg of 10 blisters in 2 bags of 5 blisters per box, Double packed | packaging pkg of 10 blisters per box, Single packed |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in ambient |
| input sample type pharmaceutical(s) | input sample type pharmaceutical(s) | input sample type pharmaceutical(s) | input liquid |
| tubing L 850 mm | tubing L 850 mm | tubing L 850 mm | tubing L 850 mm |
Still not finding the right product?
Explore all of our products under Steritest® NEO Device
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.