Skip to Content
Merck

Skip To

SLCRX13

Millex hydrophilic PTFE syringe filter

pore size 0.45 μm, diam. 13 mm, non-sterile

Synonym(s):

0.45 μm PTFE syringe filter, Millex-LCR syringe filter, disposable syringe filter, syringe filter

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
100 pkg

Available to ship TODAYfromMerck S.p.A

€421.00
1000 pkg

Available to ship TODAYfromMerck S.p.A

€2,450.00

About This Item

UNSPSC Code:
41104922
NACRES:
NB.24
eCl@ss:
32031690
Pore size:
0.45 μm
Diam.:
13 mm
Sterility:
non-sterile
Material:
PTFE membrane, polypropylene housing

€421.00


Available to ship TODAYDetails


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

PTFE membrane, polypropylene housing

sterility

non-sterile

product line

Millex

feature

holdup volume≤ 15 μL (after air purge), hydrophilic

manufacturer/tradename

Millex

parameter

10 bar max. inlet pressure (150 psi), 45 °C max. temp.

technique(s)

HPLC: suitable, UV/Vis spectroscopy: suitable, analytical sample preparation: suitable

H

21 mm

diam.

13 mm

filtration area

0.8 cm2

volume

10 mL

color

light blue

pore size

0.45 μm

input

sample type organic solution(s)
sample type mild organic solution(s)
sample type aqueous solution(s)

bubble point

≥1.4 bar at 23 °C

fitting

female Luer-Lok® inlet, male Luer outlet slip

General description

Non-sterile Millex-LCR Syringe Filters with Hydrophilic PTFE Membrane

Millex-LCR syringe filters are specifically designed for the efficient filtration of aqueous and organic solvents. Featuring a hydrophilic PTFE membrane, these filters are HPLC-certified, ensuring low levels of UV-absorbing extractables, making them ideal for analytical sample filtration.
  • SLCRX13NL replaces SLCR013NL and SLLHH13NL
  • SLCRX13NK replaces SLCR013NK and SLLHH13NK

Application

  • Suitable for sample filtration before HPLC and other analytical techniques.
  • Filtration of aqueous and organic solutions

Features and Benefits

  • HPLC Certified: Guarantees low levels of UV-absorbing extractables for reliable analytical results.
  • Hydrophilic PTFE Membrane: Offers low analyte binding and broad solvent compatibility, facilitating the filtration of various solutions and sample types.
  • Polypropylene Housing: Provides low extractables and excellent chemical compatibility
  • Easy Identification: Membrane type and pore size are clearly printed on the filter for quick reference. A light blue band identifies non-sterile Millex filters with hydrophilic PTFE membrane.
  • Recommended Sample Volume: Designed for filtering volumes of 1-10 milliliters (mL) to effectively remove particulates prior to instrumentation analysis.

Legal Information

Luer-Lok is a registered trademark of Becton-Dickinson & Co.
Millex is a trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
SLCRX13TLSLLGX13SLLG033
diam.

13 mm

diam.

13 mm

diam.

13 mm

diam.

33 mm

pore size

0.45 μm

pore size

0.45 μm

pore size

0.20 μm

pore size

0.20 μm

manufacturer/tradename

Millex

manufacturer/tradename

Millex

manufacturer/tradename

Millex

manufacturer/tradename

Millex

material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

fitting

female Luer-Lok® inlet, male Luer outlet slip

fitting

female Luer-Lok® inlet fitting, outlet tube

fitting

female Luer-Lok® inlet, male Luer outlet slip

fitting

female Luer-Lok® inlet, male Luer outlet slip

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile


Still not finding the right product?




Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

This application note describes the LC-MS-based quantitative analysis of known nitrosamine impurities following procedures 1 and 3 as given in USP general chapter <1469>.

Hydrophilic PTFE Millex® syringe filters ensure accurate dissolution testing and sample preparation for HPLC analysis.

Millex® hydrophilic PTFE syringe filters offer broad chemical compatibility and robust performance for various sample filtrations.

View All Articles

Related Content

Accurately detect and quantify trace nitrosamines (NDMA, NDEA, NEIPA, NDIPA, NDBA, etc.) in pharmaceutical drugs using our complete product portfolio and application guides for LC-MS and GC-MS. Order high-quality reference standards, columns, filters & more.

Millex wallchart





Global Trade Item Number

SKUGTIN
SLCRX13NL04054839496608
SLCRX13NK04054839496585

Questions

Reviews

No rating value

Active Filters