Advancement in the field of analytical food-chemistry has explored various experimental techniques for aflatoxins (AFs) quantification. The present study was aimed to compare four different techniques; thin-layer chromatography (TLC), high-performance liquid chromatography (HPLC), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA) for the analysis of aflatoxin B₁ (AFB₁), B₂ (AFB₂), G₁ (AFG₁) and G₂ (AFG₂) in brown rice (n = 120) being collected from Karachi, Pakistan. All the four assays provide precised, accurate and comparable results. However, some differences were observed. For instance, TLC, HPLC and LC-MS/MS methodologies offered the advantage of the quantification of individual toxins in contrast to ELISA technique. The contamination ranges of AFB₁/AFB₂ as determined by TLC, HPLC and LC-MS/MS were 1.18-9.97/0.59-1.52, 0.16-10.54/0.26-1.35 and 0.11-10.88/0.38-1.48 µg/kg, respectively. However, AFG₁ and AFG₂ were not detected in any tested samples. Furthermore, owing to low-detection limit and sensitivity, HPLC and LC-MS/MS methodologies have identified greater number of contaminated samples in comparison to TLC and ELISA techniques. The overall average results of total AFs as provided by HPLC (3.79 µg/kg) and LC-MS/MS (3.89 µg/kg) were found higher in comparison to TLC (3.68 µg/kg) and ELISA (3.70 µg/kg). On the basis of achieved results, it was concluded that TLC, HPLC, LC-MS/MS and ELISA techniques are valuable tool for the quantification of AFs in cereals and grains. Furthermore, HPLC and LC-MS/MS techniques offer an added advantage for the detection of AFs in diminutive levels.

MATERIALS
Product Number
Brand
Product Description

Supelco
Benzene, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Benzene, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Potassium hydroxide, ≥99.95% trace metals basis
Sigma-Aldrich
Iron(III) chloride solution, purum, 45% FeCl3 basis
Sigma-Aldrich
Potassium hydroxide, technical, ≥85%, powder
Sigma-Aldrich
Potassium hydroxide, ≥85% KOH basis, pellets, white
Sigma-Aldrich
o-Xylene, reagent grade, ≥98.0%
Sigma-Aldrich
Potassium hydroxide, BioXtra, ≥85% KOH basis
Supelco
Potassium hydroxide solution, volumetric, 8.0 M KOH (8.0N)
Sigma-Aldrich
Nitric acid, puriss. p.a., 65.0-67.0%
Sigma-Aldrich
Potassium hydroxide, reagent grade, 90%, flakes
Sigma-Aldrich
Nitric acid, ACS reagent, 70%
Sigma-Aldrich
Potassium hydroxide solution, 45 wt. % in H2O
Sigma-Aldrich
Benzene, puriss. p.a., reag. Ph. Eur., ≥99.7%
Sigma-Aldrich
Benzene, ACS reagent, ≥99.0%
Sigma-Aldrich
Potassium hydroxide, semiconductor grade, pellets, 99.99% trace metals basis (Purity excludes sodium content.)
Sigma-Aldrich
Potassium hydroxide, ACS reagent, ≥85%, pellets
Supelco
Sulfuric acid concentrate, 0.1 M H2SO4 in water (0.2N), eluent concentrate for IC
Millipore
TDA Reagent, suitable for microbiology
Supelco
Nitric acid concentrate, 0.1 M HNO3 in water (0.1N), eluent concentrate for IC
Sigma-Aldrich
Iron(III) chloride solution, 0.2 M in 2-methyltetrahydrofuran
Sigma-Aldrich
Nitric acid, ACS reagent, ≥90.0%
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Benzene, anhydrous, 99.8%
Sigma-Aldrich
Nitric acid, 70%, purified by redistillation, ≥99.999% trace metals basis
Supelco
Benzene, analytical standard
Sigma-Aldrich
Potassium hydroxide, tested according to Ph. Eur.
Supelco
o-Xylene, analytical standard
Supelco
o-Xylene, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Chloroform, Pharmaceutical Secondary Standard; Certified Reference Material