Merck
All Photos(2)

Documents

Safety Information

SCWP04700

Millipore

MCE Membrane Filter, 8.0 μm Pore Size

MF-Millipore, filter diam. 47 mm, hydrophilic

Sign Into View Organizational & Contract Pricing

Synonym(s):
Cellulose nitrate membrane filter discs, Hydrophilic MCE membrane filter cut discs, MF-Millipore Membrane Filter, 8 µm pore size, Mixed Cellulose Ester membrane filter discs
eCl@ss:
32031602
NACRES:
NB.24

material

mixed cellulose esters (MCE) membrane
plain filter
white filter

Quality Level

description

47 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic, white, 100 discs

sterility

non-sterile

feature

hydrophilic

manufacturer/tradename

MF-Millipore
Millipore

parameter

620 mL/min-cm2 water flow rate
65 L/min-cm2 air flow rate
75 °C max. temp.

filter L × W

1.9 cm × 4.2 cm

filter diam.

47 mm

thickness

135 μm

gravimetric extractables

6%

refractive index

n/D 1.515

matrix

MF-Millipore

pore size

8.0 μm pore size
84 % porosity

capacity

150 μg/cm2 binding capacity (protein)

bubble point

≥0.42 bar, air with water at 23 °C

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
SCWP02500SCWP09025SCWP0190R
parameter

65 L/min-cm2 air flow rate, 620 mL/min-cm2 water flow rate, 75 °C max. temp.

parameter

620 mL/min-cm2 water flow rate, 65 L/min-cm2 air flow rate, 75 °C max. temp.

parameter

620 mL/min-cm2 water flow rate, 65 L/min-cm2 air flow rate, 75 °C max. temp.

parameter

620 mL/min-cm2 water flow rate, 65 L/min-cm2 air flow rate, 75 °C max. temp.

pore size

8.0 μm pore size, 84 % porosity

pore size

8.0 μm pore size, 84 % porosity

pore size

8.0 μm pore size, 84 % porosity

pore size

8.0 μm pore size, 84 % porosity

material

mixed cellulose esters (MCE) membrane, white filter, plain filter

material

mixed cellulose esters (MCE) membrane, plain filter, white filter

material

mixed cellulose esters (MCE) membrane, plain filter, white filter

material

mixed cellulose esters (MCE) membrane, plain filter, white filter

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

-

General description

Filter Code: SCWP

Application

  • QC of fluid holding tanks
  • Fluid monitoring
  • Air monitoring
  • Particle collection
  • Particle analysis

Legal Information

MF-Millipore is a trademark of Merck KGaA, Darmstadt, Germany

Pictograms

Flame

Signal Word

Danger

Hazard Statements

Hazard Classifications

Flam. Sol. 1

Storage Class Code

4.1B - Flammable solid hazardous materials

WGK

WGK 3


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

FSL

Self-reactive substances
Nitric esters
Hazardous rank I
1st self-reactive materials


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

S Skraber et al.
Applied and environmental microbiology, 70(6), 3644-3649 (2004-06-09)
The aim of the study was to evaluate the presence of pathogenic viruses in the Moselle River and to compare the usefulness of thermotolerant coliforms and somatic coliphages as tools for river water quality assessment in terms of viral contamination.
D Rolland et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 861(2), 186-195 (2007-08-31)
Many problems concerned with the production and the purification of recombinant proteins must be addressed prior to launching an industrial production process. Among these problems, attention is focused on low-level expression that complicates the purification step and can jeopardise the
Si-Tu Xue et al.
Autophagy, 16(10), 1823-1837 (2020-01-29)
Although macroautophagy/autophagy is involved in hepatocellular carcinoma (HCC) initiation and development and has been identified as a mechanism of HCC therapy resistance, the role of ULK1 (unc-51 like autophagy activating kinase 1) in HCC remains unclear. Here, we report that

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service