Merck
All Photos(2)

TSTP04700

Millipore

Polycarbonate Membrane Filter, 3.0 μm Pore Size

Isopore, filter diam. 47 mm, hydrophilic

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
Isopore Membrane Filter
eCl@ss:
32031602
NACRES:
NB.24

material

plain filter
polycarbonate membrane
white filter

sterility

non-sterile

feature

hydrophilic

manufacturer/tradename

Isopore
Millipore

parameter

0.868 L/min-cm2-psi air flow rate
140 °C max. temp.
3628 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)
~475 mL/min-cm2 water flow rate at 10 psi (typical results)

filter diam.

47 mm

thickness

22 μm

gravimetric extractables

<1%

refractive index

n/D 1.6

matrix

Isopore

pore size

11.3 % porosity
3.0 μm pore size

bubble point

≥0.32 bar, air with water at 23 °C

shipped in

ambient

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
TSTP02500GTTP03700ATTP14250
sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

parameter

0.868 L/min-cm2-psi air flow rate, 140 °C max. temp., 3628 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), ~475 mL/min-cm2 water flow rate at 10 psi (typical results)

parameter

0.868 L/min-cm2-psi air flow rate, 140 °C max. temp., 3628 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), ~475 mL/min-cm2 water flow rate at 10 psi (typical results)

parameter

0.007 L/min-cm2-psi air flow rate, 140 °C max. temp., 3.36 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), ~16 mL/min-cm2 water flow rate at 10 psi (typical results)

parameter

125 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), 140 °C max. temp., 4.08 L/min-cm2-psi air flow rate, ~85 mL/min-cm2 water flow rate at 10 psi (typical results)

pore size

11.3 % porosity, 3.0 μm pore size

pore size

11.3 % porosity, 3.0 μm pore size

pore size

0.22 μm pore size, 13.8 % porosity

pore size

0.8 μm pore size, 5-20 % porosity

General description

The Isopore membrane is a polycarbonate that allows sample visualization on membrane surface using optical or electron microscopy. Due to precise pore diameter and consistent pore size, it allows size-based sample separation with accuracy. It may be useful in chemotaxis assay, air monitoring, and epifluorescent microscopy.

Application

  • Chemotaxis
  • Bioassays
  • Cytology
  • Air monitoring
  • Microplastics analysis

Isopore membrane filter has been used to:
  • filter microplastics associated with microbes from seawater samples
  • wrap and encapsulate tumor for implantation in mice to mimic anti-angiogenic (AA) therapy
  • filter out phytoplankton and large-sized particles
  • hold mammalian cell lines for ultraviolet (UV) irradiation studies

Features and Benefits

  • Isopore membranes have low background interference.
  • Particle retention on the membrane surface favorable for counting and analysis.
  • Non-hygroscopic and translucent material.
  • Rapid sample drying and analysis time.
  • Also available in a brown variety.

Caution

Possible reduction in flow rates may occur after autoclaving.

Legal Information

ISOPORE is a trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Seung Won Jung et al.
Scientific reports, 11(1), 6983-6983 (2021-03-28)
We investigated the dynamics of the bacterial composition and metabolic function within Akashiwo sanguinea bloom using a 100-L indoor microcosm and metagenomic next-generation sequencing. We found that the bacterial community was classified into three groups at 54% similarity. Group I
Brittan S Scales et al.
mSphere, 6(3), e0085120-e0085120 (2021-06-10)
While it is now appreciated that the millions of tons of plastic pollution travelling through marine systems carry complex communities of microorganisms, it is still unknown to what extent these biofilm communities are specific to the plastic or selected by
Denian Wang et al.
Scientific reports, 7(1), 2365-2365 (2017-05-26)
Although anti-angiogenic (AA) therapy is widely used in clinical practice, it is often challenged by insufficient efficacy and intrinsic resistance. Some studies have reported that AA therapy can even increase tumor metastasis. However, whether this is due to a specific
Haohui Duan et al.
The Journal of cell biology, 219(6) (2020-05-12)
BRCA1/2 help maintain genomic integrity by stabilizing stalled forks. Here, we identify the E3 ligase RFWD3 as an essential modulator of stalled fork stability in BRCA2-deficient cells and show that codepletion of RFWD3 rescues fork degradation, collapse, and cell sensitivity

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.