Merck
All Photos(1)

Documents

Safety Information

RAB0010

Sigma-Aldrich

Angiotensin II EIA Kit

for serum, plasma, culture supernatant and cell lysates

Sign Into View Organizational & Contract Pricing

Select a Size

Synonym(s):
Angiotensinogen, Serpin A8
NACRES:
NA.32

species reactivity

mouse, human, rat

packaging

kit of 96 wells (12 strips x 8 wells)

technique(s)

ELISA: suitable
enzyme immunoassay: suitable

input

sample type cell lysate
sample type culture supernatant(s)
sample type serum
sample type plasma

assay range

inter-assay cv: <15%
intra-assay cv: <10%
sensitivity: 2.62 pg/mL
standard curve range: 0.1-1000 ng/mL

detection method

colorimetric

shipped in

wet ice

storage temp.

−20°C

Gene Information

human ... AGT(183)

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
RAB0385RAB0006RAB0023
Sigma-Aldrich

Sigma-Aldrich

RAB0006

Adiponutrin EIA Kit

packaging

kit of 96 wells (12 strips x 8 wells)

packaging

kit of 96 wells (12 strips x 8 wells)

packaging

kit of 96 wells (12 strips x 8 wells)

packaging

kit of 96 wells (12 strips x 8 wells)

technique(s)

ELISA: suitable, enzyme immunoassay: suitable

technique(s)

ELISA: suitable, enzyme immunoassay: suitable

technique(s)

ELISA: suitable, enzyme immunoassay: suitable

technique(s)

ELISA: suitable, enzyme immunoassay: suitable

input

sample type cell lysate
sample type culture supernatant(s)
sample type serum
sample type plasma

input

sample type serum
sample type cell lysate
sample type plasma
sample type culture supernatant(s)

input

sample type cell lysate
sample type plasma
sample type culture supernatant(s)
sample type serum

input

sample type culture supernatant(s)
sample type plasma
sample type serum
sample type cell lysate

assay range

inter-assay cv: <15%
intra-assay cv: <10%
sensitivity: 2.62 pg/mL
standard curve range: 0.1-1000 ng/mL

assay range

inter-assay cv: <15%
intra-assay cv: <10%
sensitivity: 1.02 pg/mL
standard curve range: 0.1-1000 pg/mL

assay range

inter-assay cv: <15%
intra-assay cv: <10%
sensitivity: 21 pg/mL
standard curve range: 0.1-1000 ng/mL

assay range

inter-assay cv: <15%
intra-assay cv: <10%
sensitivity: 21 pg/mL
standard curve range: 0.1-1000 ng/mL

detection method

colorimetric

detection method

colorimetric

detection method

colorimetric

detection method

colorimetric

General description

The Angiotensin II Enzyme Immunoassay (EIA) Kit is an in vitro quantitative assay for detecting Angiotensin II peptide based on the principle of Competitive Enzyme Immunoassay. EIA-ANGII-1 can theoretically detect all active angiotensins, including ANGI, ANGII, ANGIII and ANGIV. However, it does not detect inactive angiotensinogen.

Immunogen

Angiotensin II, synthetic peptide

Application

Angiotensin II EIA Kit has been used for quantitative estimation of serum angiotensin-II.
For research use only. Not for use in diagnostic procedures.
Angiotensin II EIA Kit has been used for analyzing circulating and serum levels of angiotensin II (Ang II) in mice and rats respectively.
Please refer to the attached General ELISA KIT Procedure (sandwich, competitive & Indirect ELISA)

Biochem/physiol Actions

Study on in vitro model shows that mechanical stretch induced Ang II release plays a vital role in mediating stretch-induced hypertrophic response. Ang II is implicated in maintaining blood pressure and has an important role in hypertension and in the pathophysiology of cardiovascular disorders. Ang II also has an essential role in growth induction, cell migration and mitosis of vascular smooth muscle cells. It enhances the production of collagen type I and III in fibroblasts, that results in thickening of the vascular wall and myocardium, and fibrosis. Variation in Ang II gene increases the risk of myocardial infarction, hypertension and left ventricular hypertrophy. Ang II expression is associated with heart failure, cardiac remodeling, diabetes, and the proliferative and inflammatory responses to arterial injury. The pharmacological agents such as angiotensin II-converting enzyme inhibitors or angiotensin II receptor antagonists can be used for treating Ang II-induced hypertension and congestive heart failure.

Kit Components Also Available Separately

Product No.
Description
SDS

Pictograms

Corrosion

Signal Word

Warning

Hazard Statements

Precautionary Statements

Hazard Classifications

Met. Corr. 1

Storage Class Code

8A - Combustible, corrosive hazardous materials

WGK

WGK 3


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

PDSCL

Please refer to KIT Component information

PRTR

Please refer to KIT Component information

FSL

Please refer to KIT Component information

ISHL Indicated Name

Please refer to KIT Component information

ISHL Notified Names

Please refer to KIT Component information

Cartagena Act

Please refer to KIT Component information

JAN Code

キットコンポーネントの情報を参照してください


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Nima Nabavizadeh et al.
Radiation research, 193(2), 155-160 (2019-12-17)
The biological response of normal tissue to high-dose radiation treatment remains poorly understood. Alterations to the microenvironment, specifically the microvasculature, have been implicated as a significant contributor to tumoral cytotoxicity. We used contrast-enhanced ultrasound (CEU) perfusion imaging, which is uniquely
Ting Yang et al.
Journal of the American Heart Association, 5(7) (2016-07-20)
Early-life reduction in nephron number (uninephrectomy [UNX]) and chronic high salt (HS) intake increase the risk of hypertension and chronic kidney disease. Adenosine signaling via its different receptors has been implicated in modulating renal, cardiovascular, and metabolic functions as well
Fernanda S Thomaz et al.
Journal of human hypertension, 35(2), 170-180 (2020-05-28)
The human gut microbiota plays a critical role in the regulation of adiposity, obesity and metabolic and cardiovascular disease. Wasabi is a pungent spice and its active component, allyl isothiocyanate, improves plasma triacylglycerol, cholesterol and high blood pressure in rodents
Emma N Bardsley et al.
Journal of molecular and cellular cardiology, 138, 234-243 (2019-12-15)
Chronically elevated angiotensin II is a widely-established contributor to hypertension and heart failure via its action on the kidneys and vasculature. It also augments the activity of peripheral sympathetic nerves through activation of presynaptic angiotensin II receptors, thus contributing to
Gagandeep Kaur et al.
Frontiers in physiology, 12, 653045-653045 (2021-06-15)
Background: Tobacco smoking is known to be involved in the pathogenesis of several cardiopulmonary diseases. Additionally, smokers are highly susceptible to infectious agents due to weakened immunity. However, the progression of lung injury based on SARS-CoV-2-mediated COVID-19 pathogenesis amongst smokers

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service