If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
57030-U
Visiprep™ SPE Vacuum Manifold, PTFE Free
standard, 12-port model
Synonym(s):
12-port SPE Vacuum Manifold for cartridge tubes
Select a Size
Select a Size
About This Item
Recommended Products
material
UHMW PE frit
polypropylene tube
Quality Level
Agency
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
reg. compliance
suitable for FDA C-010.02
product line
Visiprep™
technique(s)
solid phase extraction (SPE): suitable
suitability
suitable for (for PFAS testing)
application(s)
environmental
food and beverages
Looking for similar products? Visit Product Comparison Guide
General description
Application
Features and Benefits
- Patented screw-type valves within each SPE port for precise flowcontrol
- Glass basin will not dissolve, fog, or discolor when exposed tosolvents
- Legs on cover allow user to easily rest cover on work surface whenremoved from the manifold
- Screw-type solvent-resistant vacuum bleed gauge and valve offerbetter sealing and vacuum control. Valve takes 1/4″ vacuumtubing.
- PP collection vessel rack accommodates autosampler vials; smallscintillation vials (22.75 mm O.D. recommended); 10 and 16 mm test tubes; and 1, 2, 5, and 10 mL volumetric flasks. An optional plate for 20 mL scintillationvials is available for 12-port models.
Legal Information
related product
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Sorry, we don't have COAs for this product available online at this time.
If you need assistance, please contact Customer Support.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Articles
A complete reversed phase HPLC-ELSD workflow, including sample preparation for the analysis of Polysorbate 80 in a monoclonal antibody formulation.
Simultaneous determination of 27 PFAS chemical compounds after enriching the water samples with SPE using a Supelclean® ENVI-WAX weak anion exchange tube.
Find more about the analysis of 16 PFAS in salmon via QuEChERS extraction and LC-MS/MS characterization following FDA Method C-010.02.
Related Content
FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
What is the spacing between ports for the 12 and 24 manifolds. Will spacing accommodate 60mL reservoirs such as PN 57022 in neighboring positions.
1 answer-
Following are the dimensions for the valve placements.
Visiprep 12 Port, Product numbers 57030-U & 57044
1 1/8" (1.14") Between valves (center to center)
1 5/8" Between rows (center to center)Visiprep 24 Port, Product numbers 57250-U & 57265
7/8" (0.875") Between valves (center to center)
1 3/8" Between rows (center to center)All ports on the 12 and 24 vacuum manifolds can only be used simultaneously with 1, 3, and 6mL tubes. In order to use all ports of the manifold with 12, 20, or 60 mL SPE tubes, Long Stem Flow Control Valves are required – see product 57048.
Helpful?
-
-
What leads to the vacuum gauge needle on the Visiprep SPE Manifold to bounce back and forth instead of being steady?
1 answer-
The fluctuation of the vacuum gauge needle usually indicates a faulty diaphragm, necessitating the replacement of the entire gauge. Part number 57035-U is the Vacuum Gauge with Bleed Valve for both the 12-Port and 24-Port Visiprep SPE Manifolds.
For the Visiprep Vacuum Gauge, the gasket is an essential matched part and, as such, cannot be replaced independently of the other components.Helpful?
-
-
What additional items are required to utilize Visiprep Manifold 57030-U?
1 answer-
To operate both the standard Visiprep SPE Manifolds (57030-U and 57044) and the Visiprep DL Manifolds (57265 and 57250-U), you will need a vacuum pump and a Waste Trap Kit (57120-U). The waste trap should be installed between the manifold and pump to ensure that the waste going into the glass basin is pulled through the front gage and out into the waste trap.
Other necessary items include:
• SPE tube of choice
• Vials, test tubes, or other collection vessels that fit the polypropylene collection vessel racks, accommodating autosampler vials, small scintillation vials, 10 and 16 mm test tubes, and 1, 2, 5, and 10-mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 24-port models.Helpful?
-
-
What is the maximum vacuum that the Visiprep Vacuum Manifold, Product 57030-U, can handle?
1 answer-
The maximum vacuum that the Visiprep Vacuum Manifold can handle is 20 inches of Mercury (Hg).
Helpful?
-
-
When I purchase the Visiprep SPE Vacuum Manifold, Product 57030-U, what additional components are required to begin using it immediately?
1 answer-
The Visiprep SPE Vacuum Manifold (57030-U) includes most items which would be required for immediate operation. Additional required items are the SPE tubes themselves, a vacuum source, and tubing to connect the manifold to the vacuum source.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-
-
Do you have a recommendation for the tubing required to connect Visiprep™ SPE Vacuum Manifold (57030-U) to my vacuum source?
1 answer-
Although any 1/4 inch ID flexible tubing should be suitable for this purpose, the product number Z255998-1PAK (10ft length) would be appropriate for this application.
Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service