コンテンツへスキップ
Merck

スキップする

SLFG050

Millex hydrophobic PTFE vent filter

pore size 0.2 μm, diam. 50 mm, non-sterile, 1/4-1/2 in. hose barb, sterilization compatible with autoclavable

別名:

0.2 μm PTFE syringe filter, Fluoropore® PTFE syringe filter, Millex-FG vent filter, Millex-FG50, Millex-FG Vacuum Line Protector, disposable syringe filter, syringe filter, vacuum line filter

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する
容量カタログ番号在庫状況単価

この商品について

UNSPSC Code:
41104922
NACRES:
NB.22
eCl@ss:
32031690
Pore size:
0.2 μm
Diam.:
50 mm
Sterility:
non-sterile
Material:
PTFE membrane, polypropylene housing
この製品は、Merck Milliporeウェブサイトでのみ注文できます。
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


Quality Level

material

PTFE membrane, polypropylene housing

sterility

non-sterile

sterilization compatibility

autoclavable compatible

product line

Millex

feature

hydrophobic

manufacturer/tradename

Millex

parameter

≥15 L/min air flow rate at 5 psi, 130 °C max. temp., 23 L/min air flow rate at 5 psi (typical), 4.13 bar max. inlet pressure (60 psi)

technique(s)

analytical sample preparation: suitable, gas filtration: suitable, vent filtration: suitable

diam.

50 mm

filtration area

19.6 cm2

housing diam.

62 mm

inlet to outlet H

71 mm

impurities

≤20 EU/device bacterial endotoxins (LAL test, Aqueous extraction)

matrix

Fluoropore®

pore size

0.2 μm

input

gas
sample type organic solution(s)

bubble point

≥17 psig, 60/40% IPA/water

fitting

inlet stepped hose barb (with Female Luer slip interior), outlet stepped hose barb (with Female Luer slip interior)

shipped in

ambient

storage temp.

no temp limit

General description

Millex syringe filter units with hydrophobic Fluoropore® membrane are ideal for in-line sterilization of gases and venting sterile containers, and filters with Fluoropore® membrane can also be used for sterilizing or clarifying organic solutions. The 50 mm Millex filter units are especially useful for vacuum line protection. All units are bi-directional.

Application

  • Sterilizing Gases
  • Vacuum Line Protection
  • Venting Sterile Containers
  • Sterilizing and Clarifying Organic Solutions

Features and Benefits

  • Ideal for vacuum line protection
  • Autoclavable up to 10 times
  • Bi-directional in flow
  • Broad chemical compatibility

Legal Information

Fluoropore is a registered trademark of Merck KGaA, Darmstadt, Germany
Millex is a trademark of Merck KGaA, Darmstadt, Germany

類似品目との比較

比較内容をすべて表示

相違点を表示

1 of 1

当該品目
SLFG850SLFG55010SLFG650
material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

material

PTFE membrane, polypropylene housing

pore size

0.2 μm

pore size

0.2 μm

pore size

0.2 μm

pore size

0.2 μm

manufacturer/tradename

Millex

manufacturer/tradename

Millex

manufacturer/tradename

Millex

manufacturer/tradename

Millex

diam.

50 mm

diam.

50 mm

diam.

50 mm

diam.

50 mm

fitting

inlet stepped hose barb (with Female Luer slip interior), outlet stepped hose barb (with Female Luer slip interior)

fitting

inlet/outlet hose barb (1/2 in.-1/4 in., with Female Luer slip interior)

fitting

inlet stepped hose barb (with Female Luer slip interior), 1/8 in. male NPT outlet connection, 1/8 in. male NPT outlet fitting

fitting

inlet stepped hose barb (1/2-1/4 in. silicone with Female Luer slip interior), 1/8 in. male NPT outlet

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile


Still not finding the right product?

Explore all of our products under

または

製品選択ツール}で選択肢を絞り込んでください。




試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする


関連コンテンツ

Learn how to effectively filter fetal bovine serum (FBS) using Stericup® Quick Release vacuum filtration devices, including flow test data and analysis.

Millex wallchart





グローバルトレードアイテム番号

カタログ番号GTIN
SLFG0501008436037120510
SLFG0500008436037120534

質問

1–3/3 質問  
  1. Are these filters autoclavable for re-use?

    1 回答
    1. When used as a vent filter for air filtration, the product may be sterilized by autoclaving for re-use. If the filters are used in liquid filtration, autoclaving and re-use is not recommended. Please see the link below to review additional information in the product user guide:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/145/471/pf04597wrev0724-ms.pdf

      役に立ちましたか?

  2. What would be your recommendation to protect my instrumentation from water intrusion?

    1 回答
    1. The recommended catalog number is SLFG05010 for the Millex-FG filter, which has a pore size of 0.20 µm and is made of hydrophobic PTFE material. The filter has a diameter of 50 mm.

      役に立ちましたか?

  3. Is there a sterile version of this filter available? Andrea

    1 回答
    1. A sterile version of Product SLFG050 is not available.