SLGP033N
Millex™ polyethersulfone syringe filter
pore size 0.22 μm, diam. 33 mm, non-sterile, hydrophilic, PFAS Validated
別名:
0.22 μm PES syringe filter, Millex-GP syringe filter, Millipore Express® PES syringe filter, disposable syringe filter, polyethersulfone syringe filter, syringe filter
About This Item
物質
polyethersulfone membrane
polypropylene housing
品質水準
認証
PFAS Validated
suitable for EPA 1633
suitable for EPA 537.1
無菌性
non-sterile
製品種目
Millex™
特徴
holdup volume≤ 80 μL (after air purge)
hydrophilic
メーカー/製品名
Millex™
パラメーター
45 °C max. temp.
8.6 bar max. inlet pressure (125 psi)
テクニック
UHPLC: suitable
analytical sample preparation: suitable
fast flow filtration: suitable
low protein-binding filtration: suitable
H
27 mm
直径
33 mm
ろ過面積
4.5 cm2
容量
100 mL
色
green
Matrix
Millipore Express®
ポアサイズ
0.22 μm
入力
sample type aqueous solution(s)
sample type mild organic solution(s)
泡立ち点
≥4.3 bar, air with water at 23 °C
フィッティング
female Luer-Lok® inlet
male Luer outlet slip
アプリケーション
PFAS testing
輸送温度
ambient
関連するカテゴリー
1 of 4
当該品目 | SLHP033N | SLHPX13 | SLGPX13 |
---|---|---|---|
diam. 33 mm | diam. 33 mm | diam. 13 mm | diam. 13 mm |
manufacturer/tradename Millex™ | manufacturer/tradename Millex™ | manufacturer/tradename Millex™ | manufacturer/tradename Millex™ |
material polyethersulfone membrane, polypropylene housing | material polyethersulfone membrane, polypropylene housing | material polyethersulfone membrane, polypropylene housing | material polyethersulfone membrane, polypropylene housing |
pore size 0.22 μm | pore size 0.45 μm | pore size 0.45 μm | pore size 0.22 μm |
fitting female Luer-Lok® inlet, male Luer outlet slip | fitting female Luer-Lok® inlet connection, female Luer-Lok® inlet fitting, male Luer outlet slip | fitting female Luer-Lok® inlet, male Luer outlet slip | fitting female Luer-Lok® inlet, male Luer outlet slip |
sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
詳細
- Validated for low levels of 42 PFAS compounds. These compounds are included in EPA 537.1 and EPA 1633. All compounds tested were below the reporting limit. Additional information is available in both the User Guide and Certificate of Quality
- Low protein binding to minimize interaction with your sample and maximize recovery
- Polypropylene housing, offering a low level of extractables and broad chemical compatibility
- Membrane type and pore size are printed on the device for easy reference
- A green band identifies non-sterile Millex™ filters with Millipore Express® PLUS PES membrane
- Recommended for filtering 10-100 milliliter (mL) volumes to remove particles prior to instrumentation analysis
アプリケーション
規格
法的情報
適切な製品が見つかりませんか。
製品選択ツール.をお試しください
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)