The ultrafiltration membrane in this product is characterized by a nominal molecular weight limit based on protein retention. An absolute linear pore diameter is not determined. However, a membrane with a 10 kDa molecular weight cutoff will retain nanoparticles of 3-9 nanometers. Please see the related article on nanoparticle ultrafiltration: https://www.sigmaaldrich.com/technical-documents/technical-article/analytical-chemistry/filtration/nanoparticle-ultrafiltration
UFC5010
Amicon® Ultra Centrifugal Filter, 10 kDa MWCO
sample volume 0.5 mL, regenerated cellulose membrane, MWCO 10 kDa
別名:
Centrifugal concentrator, 10 kDa MWCO, 0.5 mL sample volume
About This Item
おすすめの製品
物質
polypropylene cap
polypropylene tube
regenerated cellulose membrane
styrene-butadiene housing
品質水準
無菌性
non-sterile
製品種目
Amicon®
包装
pkg of 24 pkg
pkg of 500 pkg
pkg of 8 pkg
pkg of 96 pkg
メーカー/製品名
Amicon® Ultra
sustainability
Greener Alternative Product
パラメーター
0.5 mL sample volume
テクニック
protein extraction: suitable
protein purification: suitable
L
4.99 cm (1.96 in.)
直径
10.8 mm
ろ過面積
1 cm2
容量
0.5 mL
有効容積
≤500 μL
0.5 mL
ポアサイズ
10 kDa MWCO
環境により配慮した代替製品カテゴリ
輸送温度
ambient
詳細
アプリケーション
- Ultrafiltration with 10,000 Dalton molecular weight cutoff Ultracel® membrane
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
- Purification of macromolecular components found in tissue culture extracts or cell lysates, primer removal, linkers, or macromolecular labels from a reaction mix, and protein removal prior to HPLC
- Desalting, buffer exchange, and protein dialysis
特徴および利点
物理的形状
法的情報
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
この製品を見ている人はこちらもチェック
資料
Commercially available protein labeling kits provide researchers with the flexibility to customize their own immunoassay detection panels.
Protein purification is simpler with Amicon Pro. The device delivers consistent sample preparation for more reliable recovery, uncompromised purity and easier data generation.
PNGase Fast denaturing buffer and enzyme provide results similar to a conventional 20-hour protocol, reducing workflow time to about 1 hour.
Filtration methods and membrane filter selection in nanoparticle purification and production.
プロトコル
Best practices for standardizing and reducing the Extracellular Vesicle Preparation workflow, and eliminating contamination of EV preparations with dead-cell-derived vesicles.
If an antibody must be purified from a small sample volume (0.5-10 mL), then the Amicon® Pro Purification System is recommended.
Detergents are frequently used to solubilize proteins and nucleic acids during purification, but the presence of detergents may interfere with downstream analyses.
-
What is the pore diameter of Amicon® Ultra Centrifugal Filter, 10 kDa
1 回答-
役に立ちましたか?
-
-
What is the tolerance for molecular weight with these spin columns? Could you reasonably purify a protein of 15 kDa using these columns, or are the tolerances too high and would result in loss of protein into the filtrate?
1 回答-
It is recommended to choose a molecular weight cut-off that is at least two times smaller than the molecular weight of the target molecules.
役に立ちましたか?
-
-
Is this filter suitable for purifying MHC-bound peptides as filtrate/eluate while trapping proteins and antibodies as retentate following Immunoprecipitation?
1 回答-
This product is not suitable for separating protein/peptides of different sizes.
役に立ちましたか?
-
-
If a centrifuge is unable to achieve a spinning speed of 14000 X g as recommended in the protocol, is it possible to compensate by spinning the samples for a longer duration?
1 回答-
Yes, it is possible to compensate for a lower centrifuge spinning speed by increasing the duration. This can be achieved by calculating the K factor, which determines the adjustment needed in time.
役に立ちましたか?
-
-
se puede utilizar los UFC501024 para concentrar una proteina glicosilada?
1 回答-
Yes, Amicon devices like UFC501024 can be used to concentrate any protein greater than about 20 kDa.
役に立ちましたか?
-
-
Dear Sir/Mam, can you let me know how many tubes is 8 pkg? Is it 8 tubes? Best regards, Alejandra
1 回答-
It is 8 tubes per pack.
役に立ちましたか?
-
-
What is the maximum RPM that this can be spun to ensure the membrane does not perforate?
1 回答-
The recommended G force for the Amicon® Ultra-0.5 filter is 14,000 g & 1,000 g reverse spin when using a Fixed-Angle (35 º) Rotor.